Communications, control systems, medical, instrumentation, defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Parameter
+IN to –IN voltage
PC to –IN voltage
PR to –IN voltage
SC to –OUT voltage
–Sense to –OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
–0.5 to +260
–0.5 to +7.0
–0.5 to +7.0
–0.5 to +1.5
1.0
3000
1500
500
–55 to +100
–65 to +125
500 [260]
750 [390]
5 [0.57]
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F [°C]
°F [°C]
in.lbs [N.m]
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5sec; wave solder
<7sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V150B24C250BL
V1 5 0 B
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
–10 to +100
–20 to +125
C
=
–20 to +100
–40 to +125
T
=
–40 to +100
–40 to +125
H
=
–40 to +100
–55 to +125
M
=
–55 to +100
–65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
100W, 150W
5V
150W, 200W
8V
200W
12V
150W, 250W
15V
150W, 250W
24V
150W, 250W
28V
150W, 250W
36V
150W, 250W
48V
150W, 250W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Output Voltage
3V 3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
150V Mini Family
Page 1 of 13
Rev 3.0
05/2018
150V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
81.9
201.9
97.0
84.9
210
220
1.1
Min
100
Typ
150
Max
200
250
99.0
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.4
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,
please refer to output connections on page 8.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20264)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.16
0.14
8.0
1.9
83
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
150V Mini Family
Page 2 of 13
Rev 3.0
05/2018
150V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4
mA. See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
3.1
[89.3]
3.5
[99.6]
100
3000
1500
500
10
3.5
[100.3]
3.9
[110.6]
115
cURus, cTÜVus, CE
3.9
[111.3]
4.3
[121.6]
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
[grams]
ounces
[grams]
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
150V Mini Family
Page 3 of 13
Rev 3.0
05/2018
150V Input
MODULE-SPECIFIC OPERATING SPECIFICATIONS
3.3
V
OUT
, 150W (e.g. V150B3V3C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
79.5
4.14
Typ
81
170
4.3
5
±0.02
52.3
52.3
Max
213
4.46
6
±0.2
45.45
61.5
61.5
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
46.4
31.8
3.3
V
OUT
, 100W (e.g. V150B3V3C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
80.2
4.14
Typ
81.5
240
4.3
5.5
±0.02
34.8
34.8
Max
300
4.46
5.8
±0.2
30.3
41
41
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.9
21.2
5
V
OUT
, 200W (e.g. V150B5C200BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
83.8
6.03
Typ
84.9
175
6.25
5.5
±0.02
46
46
Max
219
6.47
8.5
±0.2
40
54
54
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
40.8
28
5
V
OUT
, 150W (e.g. V150B5C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
84.4
6.03
Typ
85.8
145
6.25
3.9
±0.02
34.5
34.5
Max
182
6.47
4.2
±0.2
30
40.5
40.5
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
30.6
21
8
V
OUT
, 200W (e.g. V150B8C200BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
86.4
9.36
Typ
87.4
240
9.7
5.3
±0.02
28.8
28.8
Max
300
10.1
6
±0.2
25
33.8
33.8
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.5
17.5
150V Mini Family
Page 4 of 13
Rev 3.0
05/2018
150V Input
MODULE-SPECIFIC OPERATING SPECIFICATIONS (CONT.)
12
V
OUT
, 250W (e.g. V150B12C250BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
87.1
13.7
Typ
88.1
350
14.3
7.2
±0.02
23.9
23.9
Max
438
14.9
8.4
±0.2
20.83
28.1
28.1
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
21.2
14.5
12
V
OUT
, 150W (e.g. V150B12C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
87.0
13.7
Typ
88.0
210
14.3
4.6
±0.02
14.4
14.4
Max
263
14.9
5.4
±0.2
12.5
16.9
16.9
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
15
V
OUT
, 250W (e.g. V150B15C250BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
87.8
17.1
Typ
88.9
230
17.8
8.7
±0.02
19.2
19.2
Max
288
18.5
10.5
±0.2
16.67
22.6
22.6
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
17
11.6
15
V
OUT
, 150W (e.g. V150B15C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
85
17.1
Typ
86.1
200
17.8
6.9
±0.02
11.5
11.5
Max
250
18.5
7.7
±0.2
10.0
13.5
13.5
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
10.2
7
24
V
OUT
, 250W (e.g. V150B24C250BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load Current
Current limit
Short circuit current
Min
87.1
27.1
Typ
88.6
160
28.1
8
±0.02
12
12
Max
200
29.1
12
±0.2
10.42
14.1
14.1
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
I have chosen a type of current transformer, a through-core type, with a transformation ratio of 5A/5mA. I would like to ask if the 5A on the primary side refers to the rated value or the maximum valu...
I set the registers according to the epwm_trip_zone routine in Ti, but now the program can also do what I want. When the conditions are met, after the software triggers the interrupt, the specified ep...
As shown in the picture, what role does the capacitor in the blue box play?
For these two detection quantities that need to be subtracted, adding this capacitor can improve the ability to suppress com...
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:57[/i] In recent years, with the continuous improvement of people's living standards, the three series of small household appliances, n...
Hello, I encountered a problem when using ADC multi-channel acquisition. First, I used ADC 4 channels 10-bit acquisition (A3, A2, A1, A0), adopted the internal reference voltage 2.5v, and used DMA to ...
From being a global leader to losing the market, Korean battery manufacturers have always wanted to regain the lost market and dignity, but facing Chinese battery manufacturers represented by CAT...[Details]
On August 22, the National Energy Administration released the latest data, showing that by the end of July 2025, China's total number of electric vehicle charging infrastructure will reach 16.696 m...[Details]
introduction
The concept of the smart home is gradually developing and gaining market acceptance. We believe its ultimate form lies in the interconnection of all home appliances through open i...[Details]
With the increasing number of new energy vehicles on the road, the deployment of supporting facilities for these vehicles has accelerated, and new energy vehicles have gradually entered the vision ...[Details]
Teletrac Navman has launched the Multi IQ dashcam, a cloud-based solution designed for large commercial vehicle operators. It connects up to five cameras to cover the vehicle's interior, sides, and...[Details]
Shenzhen Baowei Power Supply high frequency pure sine wave power, communication inverter power supply has two communication interfaces, RS232 and R485 interfaces, their functions and characteristic...[Details]
Methods of DC motor speed regulation:
1. The voltage regulator can be used to change the input voltage and speed directly, which is often used for large kilowatt-level motors.
2. Thyristo...[Details]
Civilian internal combustion engines operate in the range of approximately 1000-4000 rpm. This results in the engine's kinetic energy being ineffective at low or high rpm, making starting difficult...[Details]
Hair dryer structure and working principle: It is mainly used for drying and shaping hair, but it can also be used for local drying, heating and treatment in laboratories, physiotherapy rooms, ind...[Details]
As my country's industrialization continues to improve, environmental pollution is also facing tremendous pressure. In recent years, national environmental protection policies have become increasin...[Details]
A Beijing chemical project utilizes a distributed control system (DCS). The master control system primarily uses the Modbus protocol, while the remote field devices utilize the PROFIBUS-DP protocol...[Details]
According to the latest financial report data, thanks to its leading position in advanced technology, TSMC's profit performance in the second quarter of 2025 was extremely impressive, with net prof...[Details]
Using the STM32F103 as a microprocessor, a low-cost wireless WiFi music player system was designed. This system, combined with the WM-G-MR-08 (wm631) module for WiFi data reception and the VS1003B ...[Details]
summary
NFC (Near Field Communication) is a short-range, high-frequency wireless communication technology that allows contactless, point-to-point data exchange (within ten centimeters) between...[Details]
When installing circuits, we all hope to have a safe and protective electrical appliance. Circuit breakers and circuit breakers are such a thing. As we all know, a circuit breaker is an elect...[Details]