EEWORLDEEWORLDEEWORLD

Part Number

Search

PAA50F-24-N

Description
Switching Power Supplies 50W 24V 2.2A w/Cover
CategoryPower/power management   
File Size423KB,13 Pages
ManufacturerCosel
Environmental Compliance
Download Datasheet Parametric View All

PAA50F-24-N Online Shopping

Suppliers Part Number Price MOQ In stock  
PAA50F-24-N - - View Buy Now

PAA50F-24-N Overview

Switching Power Supplies 50W 24V 2.2A w/Cover

PAA50F-24-N Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerCosel
Product CategorySwitching Power Supplies
RoHSDetails
Output Voltage-Channel 124 VDC
Number of Outputs1 Output
Output Power52.8 W
Open Frame/EnclosedEnclosed
Input Voltage85 VAC to 264 VAC
Output Current-Channel 12.2 A
IndustryCommercial
Isolation Voltage3 kVAC
Mounting StyleChassis
Length6.3 in
Width3.4 in
Height1.5 in
Efficiency80 %
Input Frequency50 Hz/60 Hz
Operating Temperature Range- 10 C to + 65 C
Cooling MethodConvection
Input Voltage, Max264 VAC
Input Voltage, Min85 VAC
Load RegulationRegulated
Maximum Operating Temperature+ 65 C
Mechanical StyleOpen / Enclosed Frame
Minimum Operating Temperature- 10 C
Output Voltage V1, Nominal24 VDC
Power - Convection52.8 W
Factory Pack Quantity30
Unit Weight14.109585 oz
AC-DC Power Supplies Enclosed type
Ordering information
PAA
PAA50F
R
PAA
1
2
50
3
F
4
-5
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
*4
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
R :with Remote ON/OFF
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PAA50F-3
30
3V 10A
PAA50F-5
50
5V 10A
PAA50F-12
51.6
12V 4.3A
PAA50F-15
52.5
15V 3.5A
PAA50F-24
52.8
24V 2.2A
PAA50F-48
52.8
48V 1.1A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
POWER FACTOR
ACIN 100V
ACIN 200V
PAA50F-3
PAA50F-5
PAA50F-12
PAA50F-15
PAA50F-24
PAA50F-48
AC85 - 264 1
f
0.5typ
0.8typ
0.25typ
0.4typ
50/60 (47 - 63)
67typ
74typ
77typ
78typ
80typ
80typ
0.95typ (Io=100%)
15typ (Io=100%)
15typ (Io=100%)
0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
3
5
12
15
24
48
10
10
4.3
3.5
2.2
1.1
20max
20max
48max
60max
96max
192max
40max
40max
100max
120max
150max
240max
80max
80max
120max
120max
120max
150max
140max
140max
160max
160max
160max
200max
120max
120max
150max
150max
150max
250max
160max
160max
180max
180max
180max
300max
50max
50max
120max
150max
240max
480max
60max
60max
150max
180max
290max
600max
20max
20max
48max
60max
96max
192max
500max (ACIN 85V, Io=100%)
10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%) 100typ (ACIN 200V, Io=100%)
2.85 - 3.6
t
10%
Works over 105% of rating and recovers automatically
4.00 - 5.25V
Works at 115 - 140% of rating
LED (Green)
Optional (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10M
W
min (At Room Temperature)
-10 to +65
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2
37
X
85
X
159mm (without terminal block) (W
X
H
X
D) /400g max (without cover)
Convection
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*4
*
ACIN 100V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
1
RIPPLE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
*
1
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
*
2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE ON/OFF
*
3
INPUT-OUTPUT
-
RC
INPUT-FG
*
3
OUTPUT
-
RC-FG
*
3
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Applicable when Remote ON/OFF(optional) is added.
Please contact us about safety approvals for the model with option.
Derating is required when operated with case cover.
PAA-2
Can this circuit drive a 1W LED?
[font=楷体_GB2312][size=4]Can a 3.6V lithium battery be used to drive a 1W LED lamp? (8550 tube, 1W, 1.5A, 40V)[/size][/font] [[i] This post was last edited by Chuchukankan on 2010-2-2 22:02[/i]]...
到处看看 LED Zone
M3 UDP receiving data problem
The project requires multiple devices to communicate over the network. I have never been exposed to network communication before. I used the M3 UIP protocol to write UDP communication. The reception i...
lcn1992 Microcontroller MCU
Can a three-phase 380V inverter be connected to two live inputs? Or one live and one neutral?
Three-phase 380V inverter input: 1. Can I connect two-phase live wires to debug parameters (but not run)? 2. Can I connect two-phase live wires to run? 3. Can I connect 1 fire and 1 zero to debug para...
eeleader Industrial Control Electronics
HMI Special Topic: Basic Functions and Selection Indicators of Three-Person Machine Interface Products
Basic functions and selection indicators of human-machine interface products Basic functions:  equipment working status display, such as indicator lights, buttons, text, graphics, curves, etc.  Data a...
蓝色心情 DSP and ARM Processors
About infrared optical communication
This design implements a voice and data infrared transmission system. It uses PCM codec to get digital voice. FPGA device is used as the main control unit to multiplex and encode the room temperature ...
sumanhu FPGA/CPLD
How to make high voltage pulse power supply
RT power supply: -200~40 Frequency: 1KHZ Duty cycle adjustable 30PF load Please give me some advice, thank you!...
chencl Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1715  2378  152  331  160  35  48  4  7  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号