or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage
*
8)
0.40typ (CURRENT1)
0.20typ (CURRENT1)
50/60 (47 - 440) or DC
74typ (CURRENT1)
78typ (CURRENT1)
77typ (CURRENT1)
80typ (CURRENT1)
15typ (CURRENT1) (At cold start)
30typ (CURRENT1) (At cold start)
0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
/ ( +30V reference number )
/ ( +24V reference number )
t
12
t
15
0.7
/ 0.7
0.5
/ 0.5
1.4
/-
1.0
/-
60max
/ 96max
60max
/ 96max
600max
/ 150max
600max
/ 150max
750max
/-
750max
/-
120max
/ 240max
120max
/ 240max
160max
/ 320max
160max
/ 320max
150max
/ 300max
150max
/ 300max
180max
/ 360max
180max
/ 360max
120max
150max
150max
180max
48max
60max
200typ(ACIN 100V, Io=100%)
*
Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
9.60 - 13.2 (+V and -V are simultaneously adjusted)
13.2 - 16.5 (+V and -V are simultaneously adjusted)
11.5 - 12.5 (+V and -V CURRENT1)
14.4 - 15.6 (+V and -V CURRENT1)
Works over 105% of rated current and recovers automatically
16.8 - 24.0
20.0 - 29.0
LED (Green)
None
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50M
W
min (At Room Temperature)
-10 to +71
C
(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Not built-in to active filter
*
7)
*
12
31
X
78
X
85mm [1.22
X
3.07
X
3.35 inches] (without terminal block) (W
X
H
X
D) / 200g max (with cover : 235g max)
Convection
side is fixed.
*5
The sum of +power -power must be less than output power.
*6
t12,t15
can be used as +24 and +30.
*7
When two or more units are used,they may not comply with
the harmonic attenuator. Please contact us for details.
*8
Derating is required.
*9
Figures to rated current 1.
*10
Please contact us about safety approvals for the model with
option.
*11
Please contact us about dynamic load and input response.
*12
Please contact us about class C.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
Measured by 20MHz oscilloscope or Ripple-Noise
meter(equivalent to KEISOKU-GIKEN : RM101).
*2
Drift is the change in DC output for an eight hour period
after a half-hour warm-up at 25C.
*3
Figures for 0 to rated current 1.The current not measured
side is fixed.
*4
Figures for 0 to rated current 2.The current not measured
PBA/PBW-26
PBA/PBW-26
PBW15F
Block diagram
PBA/PBW
FUSE
AC250V
2.5A
AC IN
85
-
264V
NOISE
FILTER
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
FG
TRANSFORMER
CONTROL
INVERTER
RECTIFIER
AND
FILTER
+V
COM
DC
OUT
CURRENT
SENSING
Photocoupler
RECTIFIER
AND
FILTER
-V
CONTROL
Photocoupler
OVER VOLTAGE
PROTECTION
External view
¶
External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
18
Voltage adjust
12.2
±
1.5
[0.48]
[0.71]
2.5
[0.1]
LED
16.5
±
2
Cover name plate
[0.65]
85
[3.35]
+V
COM
70.5
[2.78]
M3
FG
34.5
31
±
0.5
[1.22]
AC(N)
15.1
±
1.5
[0.59]
[0.45] [0.37]
11.5 9.5
Terminal cover
2-M3
Mounting hole
36.5
[1.44]
Point A:C102
22.6
±
1.5
[0.89]
Name plate
[1.36]
AC(L)
[0.3]
7.5
78
-V
2-M3
Mounting hole
[3.07]
Cover (option)
¶
Tolerance :
±1
[±0.04]
¶
Weight : 200g max (with cover : 235g max)
¶
PCB Material/thickness : CEM3 / 1.6mm [0.06]
¶
Chassis material : Electric galvanizing steel board
¶
Dimensions in mm, [
]= inches
¶
Mounting torque : 0.6N
•
m(6.3kgf
•
cm)max
¶
Screw tightening torque : M3 0.8N
•
m(8.5kgf
•
cm)max
¶
Please connect safety ground to the unit in 2-M3 holes.
60
±
0.5
[2.36]
5
[0.2]
[0.71]
18
[1.22]
31
PBA15F
PBW15F
[1.36]
34.5
PBA/PBW-27
PBA/PBW-27
AC-DC Power Supplies Enclosed Type
Ordering information
PBA/PBW
PBA/PBW
PBW30F
PB
1
2
W
3
30
4
F
5
-O
6
-O
R
Recommended EMI/EMC Filter
NAC-06-472
1Series
name
2Dual
output
3Output
wattage
4Universal
input
5Output
voltage
6Optional
*10
C :with Coating
G :Low leakage current
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBW30F-5
15
VOLTAGE[V]
*
6
t
5 ( +10 )
CURRENT1[A] 1.5
CURRENT2[A]
*
5
2.0
*
5
PBW30F-12
31.2
t
12 ( +24 )
1.3
1.7
PBW30F-15
30.0
t
15 ( +30 )
1.0
1.4
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT1[A]
CURRENT2[A]
*
5
*
9
LINE REGULATION[mV]
*
11
*
3
LOAD REGULATION 1[mV]
*
11
*
4
LOAD REGULATION 2[mV]
*
11
0 to +50
C
*
1
RIPPLE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
*
1
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
DRIFT[mV]
*
2
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (At only AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
PBW30F-5
PBW30F-12
PBW30F-15
AC85 - 264 1
f
or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage
*
8)
0.4typ (CURRENT1)
0.7typ (CURRENT1)
0.25typ (CURRENT1)
0.4typ (CURRENT1)
50/60 (47 - 440) or DC
75typ (CURRENT1)
77typ (CURRENT1)
78typ (CURRENT1)
75typ (CURRENT1)
81typ (CURRENT1)
79typ (CURRENT1)
15typ (CURRENT1) (At cold start)
30typ (CURRENT1) (At cold start)
0.30/0.65max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
/ ( +10V reference number )
t
12
/ ( +24V reference number )
t
15
/ ( +30V reference number )
t
5
1.5
/ 1.5
1.3
/ 1.3
1.0
/ 1.0
2.0
/-
1.7
/-
1.4
/-
20max
/ 36max
60max
/ 96max
60max
/ 96max
250max
/ 100max
600max
/ 150max
600max
/ 150max
500max
/-
750max
/-
750max
/-
80max
/ 240max
120max
/ 240max
120max
/ 240max
140max
/ 320max
160max
/ 320max
160max
/ 320max
120max
/ 300max
150max
/ 300max
150max
/ 300max
160max
/ 360max
180max
/ 360max
180max
/ 360max
50max
120max
150max
60max
150max
180max
20max
48max
60max
200typ(ACIN 100V, Io=100%)
*
Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
4.99 - 6.00 (+V and -V are simultaneously adjusted) 9.60 - 13.2 (+V and -V are simultaneously adjusted) 13.2 - 16.5 (+V and -V are simultaneously adjusted)
4.99 - 5.30 (+V and -V CURRENT1)
11.5 - 12.5 (+V and -V CURRENT1)
14.4 - 15.6 (+V and -V CURRENT1)
Works over 105% of rated current and recovers automatically
6.90 - 10.0
16.8 - 24.0
20.0 - 29.0
LED (Green)
None
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50M
W
min (At Room Temperature)
-10 to +71
C
(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Not built-in to active filter
*
7)
*
12
31
X
78
X
103mm [1.22
X
3.07
X
4.06 inches] (without terminal block) (W
X
H
X
D) / 270g max (with cover : 310g max)
Convection
side is fixed.
*5
The sum of +power -power must be less than output power.
*6
t5,t12,t15
can be used as +10,+24 and +30.
*7
When two or more units are used,they may not comply with
the harmonic attenuator. Please contact us for details.
*8
Derating is required.
*9
Figures to rated current 1.
*10
Please contact us about safety approvals for the model with
option.
*11
Please contact us about dynamic load and input response.
*12
Please contact us about class C.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
Measured by 20MHz oscilloscope or Ripple-Noise
meter(equivalent to KEISOKU-GIKEN : RM101).
*2
Drift is the change in DC output for an eight hour period
after a half-hour warm-up at 25C.
*3
Figures for 0 to rated current 1.The current not measured
side is fixed.
*4
Figures for 0 to rated current 2.The current not measured
PBA/PBW-28
PBA/PBW-28
PBW30F
Block diagram
PBA/PBW
FUSE
AC250V
3.15A
AC IN
85
-
264V
NOISE
FILTER
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
FG
TRANSFORMER
CONTROL
INVERTER
RECTIFIER
AND
FILTER
+V
COM
DC
OUT
CURRENT
SENSING
Photocoupler
RECTIFIER
AND
FILTER
-V
CONTROL
Photocoupler
OVER VOLTAGE
PROTECTION
External view
¶
External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details.
18
Voltage adjust
12.2
±
1.5
[0.48]
[0.71]
2.5
[0.1]
LED
16.5
±
2
Cover name plate
[0.65]
103
[4.06]
+V
COM
[2.78]
M3
70.5
FG
[0.3]
7.5
AC(N)
[0.45] [0.37]
11.5 9.5
15.1
±
1.5
[0.59]
Terminal cover
2-M3
Mounting hole
46
±
0.5
[1.81]
40.5
[1.59]
22.6
±
1.5
[0.89]
Point A:C102
Name plate
2-M3
Mounting hole
36.5
AC(L)
[1.44]
78
-V
Cover (option)
[3.07]
¶
Tolerance :
±1
[±0.04]
¶
Weight : 270g max (with cover : 310g max)
¶
PCB Material/thickness : CEM3 / 1.6mm [0.06]
¶
Chassis material : Electric galvanizing steel board
¶
Dimensions in mm, [
]= inches
¶
Mounting torque : 0.6N
•
m(6.3kgf
•
cm)max
¶
Screw tightening torque : M3 0.8N
•
m(8.5kgf
•
cm)max
¶
Please connect safety ground to the unit in 2-M3 holes.
75
±
0.5
[2.95]
8.5
[0.33]
[0.71]
18
[1.22]
31
PBA30F
PBW30F
34.5
[1.36]
PBA/PBW-29
PBA/PBW-29
AC-DC Power Supplies Enclosed Type
Ordering information
PBA/PBW
PBA/PBW
PBW50F
PB
1
2
W
3
50
4
F
5
-O
6
-O
R
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
1Series
name
2Dual
output
3Output
wattage
4Universal
input
5Output
voltage
6Optional
*9
C :with Coating
G :Low leakage current
(0.15mA max / ACIN 240V)
E :Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T :Vertical terminal block
J :Connector type
R :with Remote ON/OFF
N :with Cover
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBW50F-5
30
VOLTAGE[V]
*
8
t
5 ( +10 )
CURRENT1[A] 3.0
CURRENT2[A]
*
6
4.0
*
6
PBW50F-12
50.4
t
12 ( +24 )
2.1
2.7
PBW50F-15
51
t
15 ( +30 )
1.7
2.4
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR(Io=100%)
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT1[A]
CURRENT2[A]
*
6
LINE REGULATION[mV]
LOAD REGULATION 1[mV]
*
4
LOAD REGULATION 2[mV]
*
5
0 to +50
C
*
1
RIPPLE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
*
1
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
DRIFT[mV]
*
2
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE ON/OFF
INPUT-OUTPUT
-
RC
*
7
INPUT-FG
OUTPUT
-
RC-FG
*
7
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (At only AC input)
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
PBW50F-5
PBW50F-12
PBW50F-15
AC85 - 264 1
f
or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage
*
3)
0.45typ (CURRENT1)
0.70typ (CURRENT1)
(CURRENT1)
0.30typ
0.40typ (CURRENT1)
50/60 (47 - 63)
76typ (CURRENT1)
81typ (CURRENT1)
81typ (CURRENT1)
77typ (CURRENT1)
83typ (CURRENT1)
83typ (CURRENT1)
0.98typ
0.99typ
0.87typ
0.93typ
15typ (CURRENT1) (At cold start)
30typ (CURRENT1) (At cold start)
0.40/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
/ ( +10V reference number )
t
12
/ ( +24V reference number )
t
15
/ ( +30V reference number )
t
5
3.0
/ 3.0
2.1
/ 2.1
1.7
/ 1.7
4.0
/-
2.7
/-
2.4
/-
20max
/ 36max
48max
/ 96max
60max
/ 96max
250max
/ 100max
600max
/ 150max
600max
/ 150max
500max
/-
750max
/-
750max
/-
80max
/ 240max
120max
/ 240max
120max
/ 240max
140max
/ 320max
160max
/ 320max
160max
/ 320max
120max
/ 300max
150max
/ 300max
150max
/ 300max
160max
/ 360max
180max
/ 360max
180max
/ 360max
50max
120max
150max
60max
150max
180max
20max
48max
60max
350typ(ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
4.99 - 6.00 (+V and -V are simultaneously adjusted) 9.60 - 13.2 (+V and -V are simultaneously adjusted) 13.2 - 16.5 (+V and -V are simultaneously adjusted)
4.99 - 5.30 (+V and -V CURRENT1)
11.5 - 12.5 (+V and -V CURRENT1)
14.4 - 15.6 (+V and -V CURRENT1)
Works over 105% of rated current and recovers automatically
6.90 - 10.0
16.8 - 24.0
20.0 - 29.0
LED (Green)
Optional (Required external power source)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
-10 to +71
C
(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2
*
10
31
X
82
X
120mm [1.22
X
3.23
X
4.72 inches] (without terminal block) (W
X
H
X
D) / 280g max (with cover : 325g max)
Convection
*5
Figures for 0 to rated current 2.The current not measured
side is fixed.
*6
The sum of +power -power must be less than output power.
*7
RC is applied to remote ON/OFF option. RC is isolated with
input/output and FG.
*8
t5,t12,t15
can be used as +10,+24 and +30.
*9
Please contact us about safety approvals for the model with
option.
*10
Please contact us about class C.
*
Parallel operation with other model is not possible.
*
Derating is required when operated with cover.
*
A sound may occur from power supply at peak loading.
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
Measured by 20MHz oscilloscope or Ripple-Noise
meter(equivalent to KEISOKU-GIKEN : RM101).
*2
Drift is the change in DC output for an eight hour period
after a half-hour warm-up at 25C.
*3
Derating is required.
*4
Figures for 0 to rated current 1.The current not measured
Set Server = New OPCServer 'Generate OPC object, Servers = Server.GetOPCServers("") Server.Connect sServerName, "" 'Connect to OPC server Server.OPCGroups.DefaultGroupUpdateRate = 800 'Set the refresh...
In this lab, we introduce an active circuit, the operational amplifier, which has certain properties (high input resistance, low output resistance, and large differential gain) that make it a nearly i...
The code I wrote based on basicRF cannot receive data after adding PA, but I can receive data when turning off PA. The PA part of the code is also written with reference to basicRF, but the three pins...
EPROM is a ROM memory with erasable function. It can be reprogrammed after erasing. Before writing, the contents inside must be cleared by irradiating the transparent window on its IC card with ultrav...
With the rapid development of science and technology, especially the widespread application of digital technology and various ultra-large-scale integrated circuits, electronic equipment, especially...[Details]
Today, with the increasing integration of functions, mobile phones can also be used as portable media players (PMP), digital cameras, handheld computers (PDAs), and even global positioning systems ...[Details]
introduction
Throughout the history of automotive lighting, power has always played an important role. Initially, cars only needed headlights to see the road in the dark. Later, other light so...[Details]
As cellular phones become more advanced, the power consumption of the system during operation and the power consumption during standby are also increasing. Therefore, the power management design of...[Details]
Aromatic gases are widely present in food, medicine, cosmetics and various daily chemical products, such as snacks, liquor, spices, Chinese herbal medicines, plasters, perfumes, soaps, shampoos, et...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
I've been studying dot matrix recently. It looks simple, but it takes a while to master it completely! The 8*8 dot matrix hardware circuit I'm making now is like this. The row is driven by 74HC138 + t...[Details]
introduction
MAX6636 is a multi-channel precision temperature monitor that can not only monitor local temperature, but also connect up to 6 diodes externally. Each channel has a programmable...[Details]
Abstract: Aiming at the needs of coal-rock acoustic emission signal monitoring system, a data acquisition circuit with 24-bit resolution and 16-channel synchronous data acquisition function is desi...[Details]
0 Introduction
High-precision current source can provide high-precision current supply for precision instruments, and is suitable for automatic measurement tasks of various resistors in semico...[Details]
The serial interface real-time clock chip DS1302 launched by Dallas Company in the United States can trickle charge the backup battery of the clock chip. Due to the main features of the chip such a...[Details]
System Overview
The system consists of a signal preprocessing circuit, a single-chip computer AT89C2051, a systematic LED display module, a serial port data storage circuit and system software...[Details]
Temperature compensated quartz crystal oscillator (TCXO) is widely used as a high-precision frequency source in communication systems, radar navigation systems, precision measurement and control sy...[Details]
One in five car failures are caused by batteries, a problem that will become more serious in the coming years as electric-by-wire, start/stop engine management and hybrid (electric/gas) vehicles be...[Details]
At present, with the diversification of portable products and the almost harsh requirements for audio and video parts, the power consumption requirements of the whole machine have been raised to a ...[Details]