Angle Bracket, Angle Bracket Tapped, Without Angle Bracket
38330, 38336
p. 2-3
38540
p. 16-17
Shallow Bracket
38330
38542
Deep Bracket
38330, 38336
38540
p. 4-5
p. 18-19
p. 6-7
p. 20-21
Cable Mount Plugs and Sockets
Cable Clamp End
38331, 38336
38541
p. 8-9
p. 22-23
Cable Clamp Top, Cable Clamp Top with Keeper, Cable Clamp Top with Latch
38330, 38331, 38336
p. 10-11
p. 24-25
38541
Flared Hole End
38330, 38336
38540
Flared Hole Top
38330, 38331, 38336
38540
p. 12-13
p. 26-27
p. 14-15
p. 28-29
FEATURES AND SPECIFICATIONS
Features and Benefits
n
Sizes 2 to 33 circuits
n
Robust blade contacts resist damage from
improper mating
n
Large surface area of dual wipe female
contact produces maximum current
capacity
n
No de-rating required. All circuits rated for
full current load
n
Extra long pre-grounding contact engages
before any other contacts for greater safety.
Electrical
Voltage: 250V
Maximum Current:
10 Amp
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
Mechanical
Operating Temperature:
150
o
C
38330, 38336
Angled Bracket (AB)
Angle Bracket Tapped (ABT)
Less Angle Bracket (LAB)
Physical
Base Insulator: High-grade phenolic, black
Plug Contact: Brass
Plug Contact Plating: Tin
Socket Contact: Phosphor bronze
Socket Contact Plating: Tin
Pre-grounding Contact: Heavy-duty plated brass
SUGGESTED PANEL MOUNTING DIMENSIONS
CONTACT TAILS
Molex offers a wide selection of contact tails. Consult factory for
availablility and part numbers of other styles
Fig. D
Diameter
.156”
(3,96)
Reference Information
UL :
CSA:
File E34763
File 22156
.66”
(16,8)
38330-XX02
Diameter
.156”
(3,96)
.020”
(0,51)
Fig. E
.031”
(0,80)
Diameter
.156”
(3,96)
P Solder Eye (Standard)
.07” x .10”
(1,78 x 2,54)
.30”
(7,62)
.38”
(9,65)
P
7
Printed Circuit and
Wire Wrap, Short
.25”
(6,35)
.045” square
(1,14)
.97”
(24,6)
.078”
(1,98)
.44”
(11,1)
Diameter
.672”
(17,1)
38330-XX03-15
S
1
Quick Connect
.22”
(5,59)
Diameter
.156”
(3,96)
.06”
(1,59)
.44”
(11,1)
.110” x .020
(2,79 x 0,51)
P
1
Quick Connect
.39”
(9,91)
.110” x .020
(2,79 x 0,51)
Fig. F
Fig. G
Diameter
.156”
(3,96)
S Solder Eye (Standard)
.22”
(5,59)
1.015”
(25,8)
.07” x .10”
(1,78 x 2,54)
.25”
(6,35)
S
6
Printed Circuit
.10”
(2,54)
.03” x .04”
(0,76 x 1,02)
1.38”
(34,9)
38330-XX18-33
.06”
(1,59)
.032”
(0,81)
Diameter
.156”
(3,96)
1.375”
(34,9)
P
4
Wire Wrap, Long
.75” .63”
(19,1) (16,0)
.045” square
(1,14)
Diameter
.156”
(3,96)
Contact Orientation
The polarization arrangement numbers shown below are for sockets, as viewed from the wiring side. Plug numbering is the opposite. A heavy-duty polarizing/ground contact is in position 14 for Nos. 3324, 3327,
3330 and in position 17 for No. 3333. * Indicates location of pre-grounding contact. † Pregrounding contact is standard.
38330-XX02
38330-XX03
38330-XX04
38330-XX06
38336-8XXX
38330-XX08
38330-XX10
38330-XX12
38330-XX15 to 38330-XX21
38330-XX24 to 38330-XX30
38330-XX33
ORDERING INFORMATION AND DIMENSIONS
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
38330, 38336
Part #
in
3302*
3303
3304
3306
3306-8
3308
3310
3312
3315
3318
3321
3324
3327
3330
3333
0.66
1.00
0.75
1.00
1.00
1.25
1.56
1.25
1.63
1.94
2.25
2.56
2.88
3.19
3.50
T
mm
16,7
25,4
19,1
25,4
25,4
31,8
39,7
31,8
41,3
49,2
57,2
65,1
73,0
81,0
88,9
U
in
--
.44
.69
.69
.69
.69
.69
.94
1.00
1.00
1.00
1.00
1.00
1.00
1.00
V
mm
--
11,1
17,5
17,5
17,5
17,5
17,5
23,8
25,4
25,4
25,4
25,4
25,4
25,4
25,4
Part #
mm
32,1
27,0
33,3
33,3
33,3
33,3
33,3
39,7
42,9
42,9
42,9
42,9
42,9
42,9
42,9
3302*
3303
3304
3306
3306-8
3308
3310
3312
3315
3318
3321
3324
3327
3330
3333
Fig. #
in
D
E
F
E
E
F
F
F
F
G
G
G
G
G
G
.969
.750
1.000
1.000
1.000
1.000
1.000
1.250
1.375
1.250
.938
1.250
1.562
1.875
2.188
A
mm
24,6
19,1
25,4
25,4
25,4
25,4
25,4
31,8
34,9
31,8
23,8
31,8
39,7
47,6
55,6
B
in
--
1.016
.781
1.031
1.031
1.281
1.578
1.266
1.640
1.953
2.265
2.578
2.890
3.203
3.515
C
mm
--
25,8
19,8
26,2
26,2
32,5
40,1
32,2
41,7
49,6
57,5
65,5
73,4
81,4
89,3
in
1.27
1.06
1.31
1.31
1.31
1.31
1.31
1.56
1.69
1.69
1.69
1.69
1.69
1.69
1.69
in
--
.453
.719
.719
.719
.719
.719
.953
1.016
--
--
--
--
--
--
mm
--
11,5
18,3
18,3
18,3
18,3
18,3
24,2
25,8
--
--
--
--
--
--
PLUGS
Angle Bracket (-AB)
Order #
38330-0102
38330-0103
38330-0104
38330-0106
38336-8001
38330-0108
38330-0110
38330-0112
38330-0115
38330-0118
38330-0121
38330-0124
38330-0127
38330-0130
38330-0133
Engineering #
P-3302-AB
P-3303-AB
P-3304-AB
P-3306-AB
P-3306-8-AB
P-3308-AB
P-3310-AB
P-3312-AB
P-3315-AB
P-3318-AB
P-3321-AB
P-3324-AB
P-3327-AB
P-3330-AB
P-3333-AB
Angle Bracket Tapped (-ABT)
Order #
38330-1502
38330-1503
38330-1504
38330-1506
38336-8015
38330-1508
38330-1510
38330-1512
38330-1515
38330-1518
38330-1521
38330-1524
38330-1527
38330-1530
38330-1533
Engineering #
P-3302-ABT
P-3303-ABT
P-3304-ABT
P-3306-ABT
P-3306-8-ABT
P-3308-ABT
P-3310-ABT
P-3312-ABT
P-3315-ABT
P-3318-ABT
P-3321-ABT
P-3324-ABT
P-3327-ABT
P-3330-ABT
P-3333-ABT
Less Angle Bracket (-LAB)
Order #
38330-2202
38330-2203
38330-2204
38330-2206
38336-8022
38330-2208
38330-2210
38330-2212
38330-2215
38330-2218
38330-2221
38330-2224
38330-2227
38330-2230
38330-2233
Engineering #
P-3302-LAB
P-3303-LAB
P-3304-LAB
P-3306-LAB
P-3306-8-LAB
P-3308-LAB
P-3310-LAB
P-3312-LAB
P-3315-LAB
P-3318-LAB
P-3321-LAB
P-3324-LAB
P-3327-LAB
P-3330-LAB
P-3333-LAB
SOCKETS
Angle Bracket (-AB)
Order #
38330-0502
38330-0503
38330-0504
38330-0506
38336-8005
38330-0508
38330-0510
38330-0512
38330-0515
38330-0518
38330-0521
38330-0524
38330-0527
38330-0530
38330-0533
Engineering #
S-3302-AB
S-3303-AB
S-3304-AB
S-3306-AB
S-3306-8-AB
S-3308-AB
S-3310-AB
S-3312-AB
S-3315-AB
S-3318-AB
S-3321-AB
S-3324-AB
S-3327-AB
S-3330-AB
S-3333-AB
Angle Bracket Tapped (-ABT)
Order #
38330-1902
38330-1903
38330-1904
38330-1906
38336-8019
38330-1908
38330-1910
38330-1912
38330-1915
38330-1918
38330-1921
38330-1924
38330-1927
38330-1930
38330-1933
Engineering #
S-3302-ABT
S-3303-ABT
S-3304-ABT
S-3306-ABT
S-3306-8-ABT
S-3308-ABT
S-3310-ABT
S-3312-ABT
S-3315-ABT
S-3318-ABT
S-3321-ABT
S-3324-ABT
S-3327-ABT
S-3330-ABT
S-3333-ABT
Less Angle Bracket (-LAB)
Order #
38330-2602
38330-2603
38330-2604
38330-2606
38336-8026
38330-2608
38330-2610
38330-2612
38330-2615
38330-2618
38330-2621
38330-2624
38330-2627
38330-2630
38330-2633
Engineering #
S-3302-LAB
S-3303-LAB
S-3304-LAB
S-3306-LAB
S-3306-8-LAB
S-3308-LAB
S-3310-LAB
S-3312-LAB
S-3315-LAB
S-3318-LAB
S-3321-LAB
S-3324-LAB
S-3327-LAB
S-3330-LAB
S-3333-LAB
FEATURES AND SPECIFICATIONS
Features and Benefits
n
Sizes 15 to 33 circuits
n
Robust blade contacts resist damage
fromimproper mating
n
Large surface area of dual wipe female
contact produces maximum current
capacity
n
No de-rating required. All circuits rated
for full current load
n
Extra long pre-grounding contact
engages before any other contacts for
greater safety.
Electrical
Voltage: 250V
Maximum Current: 10 Amp
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
Mechanical
Operating Temperature:
150
o
C
38330
Shallow Bracket (SB)
Physical
Base Insulator:High-grade phenolic, black
Plug Contact: Brass
Plug Contact Plating: Tin
Socket Contact: Phosphor bronze
Socket Contact Plating: Tin
Pre-grounding Contact: Heavy-duty plated brass
SUGGESTED PANEL MOUNTING DIMENSIONS
CONTACT TAILS
Molex offers a wide selection of contact tails. Consult factory for
availablility and part numbers of other styles
Reference Information
UL :
CSA:
File E34763
File 22156
.032”
(0,81)
Fig. K
1.08”
(27.4)
P Solder Eye (Standard)
.07” x .10”
(1,78 x 2,54)
.30”
(7,62)
P
7
Printed Circuit and
Wire Wrap, Short
.25”
(6,35)
.38”
(9,65)
.045” square
(1,14)
1.38”
(34.9)
.44”
(11,1)
Diameter
.187”
(4,75)
S
1
Quick Connect
.22”
(5,59)
.110” x .020
(2,79 x 0,51)
P
1
Quick Connect
.39”
(9,91)
.110” x .020
(2,79 x 0,51)
S Solder Eye (Standard)
.22”
(5,59)
Diameter
.190”
(4.83)
.07” x .10”
(1,78 x 2,54)
.25”
(6,35)
S
6
Printed Circuit
.10”
(2,54)
.03” x .04”
(0,76 x 1,02)
P
4
Wire Wrap, Long
.75” .63”
(19,1) (16,0)
.045” square
(1,14)
Contact Orientation
The polarization arrangement numbers shown below are for sockets, as viewed from the wiring side. Plug numbering is the opposite. A heavy-duty polarizing/ground contact is in position 14 for Nos. 3324, 3327,
Recently I saw BYD and CATL conducting needle penetration tests on power batteries. I didn't know before that this kind of battery would be tested in this way to verify its safety. I have forwarded a ...
I am working on a UPS project. My boss wants us to program in assembly first, and then switch to C when we have time.I have read books and C examples on the Internet for two months, but I still don't ...
The relevant information of LM3S says: The CRC check in the CAN communication process is generated by hardware and does not require software implementation. Can it be implemented in software instead o...
I actually received this board before the New Year. Due to some special reasons this year, I haven't updated it. I'm sorry, so today I took advantage of the holiday to write another experience report....
How do you know if a machine is operating properly? The answer: by leveraging deep learning to detect anomalies in routine vibration data from industrial machines. Anomaly detection has many uses, ...[Details]
Abstract:
With the increasing complexity of smart vehicle electrical and electronic architectures, the full lifecycle management of vehicle electronic control components faces multiple challe...[Details]
A vacuum eutectic furnace is a critical piece of equipment used in the manufacturing and processing of various materials, particularly in the fields of microelectronics and nanotechnology. One of t...[Details]
Limited vocabulary recognition
According to the number of characters, words or short sentences in the vocabulary, it can be roughly divided into: less than 100 is small vocabulary; 100-1000 is...[Details]
According to foreign media reports, Nissan Motor has recently reached a cooperation with US battery technology company LiCAP Technologies to jointly promote the research and development of next-gen...[Details]
Electric vehicles' 12V batteries don't rely on a generator to power them. Only gasoline-powered vehicles rely on the engine to drive a generator to generate electricity while driving, which is used...[Details]
Learned the following information.
Customer product: industrial computer motherboard
Glue application area: CPU/BGA filling
Glue color requirements: black or t...[Details]
Chinese characters are extensive and profound, and there are many different names for ESD tubes. How many of them do you know?
As far as I know, ESD diodes are currently known as ESD p...[Details]
The difference between a series inverter and a parallel inverter is that they use different oscillation circuits. A series inverter connects L, R, and C in series, while a parallel inverter connect...[Details]
There are many motors that can use thyristor speed control, and they can be used in almost all industries. Various types of motors, such as fans, pumps, AC motors, DC motors, torque motors, single-...[Details]
Lightweighting of automobiles is still a relatively unfamiliar term for automobiles. With the continuous improvement of environmental protection requirements, relevant regulations have also put for...[Details]
As the range of electric vehicles continues to increase, driving electric vehicles for long-distance travel has become a trend. For high-speed travel, how much impact will high-speed driving of ele...[Details]
On August 21, according to a report by Korean media SEDaily yesterday, according to semiconductor industry sources, the HBM4 samples provided by Samsung to Nvidia last month have passed initial tes...[Details]
1. Introduction
In 2015, Apple's new MacBook and Apple Watch both featured force-sensing technology, which Apple calls Force Touch. Each time a user presses the touchpad, the device not only p...[Details]
Qiangmao, your trusted semiconductor solutions partner, sincerely invites you to visit Electronics India 2025, South Asia's leading trade show for electronic components, systems, applications...[Details]