EEWORLDEEWORLDEEWORLD

Part Number

Search

8493

Description
Non-Heat Shrink Tubing and Sleeves HFC 1/2 TWIST BLACK
CategoryWire/cable   
File Size137KB,1 Pages
ManufacturerHeyco
Environmental Compliance
Download Datasheet Parametric View All

8493 Online Shopping

Suppliers Part Number Price MOQ In stock  
8493 - - View Buy Now

8493 Overview

Non-Heat Shrink Tubing and Sleeves HFC 1/2 TWIST BLACK

8493 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerHeyco
Product CategoryNon-Heat Shrink Tubing and Sleeves
RoHSDetails
ProductConduits
ColorBlack
Size1/2 in
PackagingBulk
Factory Pack Quantity1000
Unit Weight0.634931 oz
“Stay Connected”
with
®
Liquid Tight Conduit, Tubing & Fittings
Heyco-Flex Quick Twist Conduit Fittings
For use with Heyco-Flex
I and II Conduit and Tubing
Straight-Thru, Snap-In and NPT Hubs
One-piece solution with smooth
internal surfaces provides for
easier wire routing, protection,
and installation.
Easy, permanent assembly: the
installer twists the tubing over the
connector ferrule.
Unique locking fingers accommodate
various panel thicknesses.
All nylon construction is resistant to
salt water, weak acids, gasoline,
alcohol, oil, grease, and common
solvents. (This feature is not assessed
by UL certification and testing.)
Suitable for a wide array of electrical
applications:
Commercial and Industrial HVAC
Systems
Motorized Equipment
Enclosed Power Sources
Garage Door Openers
Major Appliances
Finishing collars available to neaten
rough cut tubing ends.
Assembly Tool available for
assembling Quick Twist Fittings into
HF1 and HF2 Conduit and Tubing
(see page 2-14)
Snap-In Hubs
Snap-in Fittings are UL recognized for
use with Heyco-Flex II Tubing.
Suitable for dry location only.
NPT Hubs
NPT threaded fittings are UL approved
for use with Heyco-Flex I & II Conduit
and Tubing.
If using a tapped hole, Teflon® tape is
needed on the threads of the
connector, for all other applications an
O-ring and Locknut are needed to
attain liquid tight.
Locknuts not included.
To order nylon
or metal locknuts separately, see
pages 2-17 and 2-18.
See page 2-20 for O-Rings.
FITS
PART NO.
TUBING
TRADE Black Black w/ Gray
SIZE
Finishing
Collar*
DESCRIPTION
A
Mounting
Hole Dia.
in.
mm.
PART DIMENSIONS
B
C
D
E
Overall
Body
Wrenching Nut
Length
Length
Thickness Flat Size
in.
mm.
33,8
35,0
38,0
in.
.34
.39
.39
mm.
8,7
9,9
9,9
in.
.09
.09
.09
mm.
2,3
2,3
2,3
in.
mm.
Snap-In Hubs - For use with Heyco-Flex II Tubing
1/4
3/8
1/2
3/4
8515
8485
8490
8495
8485FC
8490FC
8495FC
8516
8486
8491
8496
HFC 1/4-S-Twist .540 13,7 1.33
HFC 3/8-S-Twist
.875 22,2 1.38
HFC 1/2-S-Twist
HFC 3/4-S-Twist 1.109 28,2 1.50
.75 19,1
1.00 25,4
1.25 31,8
NPT Hubs - For use with Heyco-Flex I and II Conduit and Tubing
1/4
3/8
1/2
3/4
8517
8487
8493
8497
8487FC
8493FC
8497FC
8518
8488
8494
8498
HFC 1/4-Twist
HFC 3/8-Twist
HFC 1/2-Twist
HFC 3/4-Twist
.540 13,7 1.56
.875 22,2 1.72
1.109 27,8 1.84
39,6
43,7
46,7
.47
.63
.63
11,8
15,9
15,9
.20
.20
.20
5,1
5,1
5,1
.75 19,1
1.18 30,0
1.37 34,8
Standard colors black and gray.
*Collar not assembled.
B
C
D
.075 (1,9mm)
.045 (1,1mm)
A
E
Panel
Thickness
Range
.105 (2,7mm)
.140 (3,6mm)
Mounting Hole
Snap-In Hub
B
C
D
E
NPT Hub
SU
FOR
Heyco-Flex Quick Twist Finishing Collars
For use with Heyco-Flex
I and II Conduit
FITS CONDUIT/
TRADE SIZE
3/8
1/2
3/4
PART NO.
Black
8474
8475
8476
Gray
8482
8483
8484
HFC TWIST 3/8 COLLAR
HFC TWIST 1/2 COLLAR
HFC TWIST 3/4 COLLAR
DESCRIPTION
Standard colors black and gray. Consult Heyco for other colors. (Not available in 1/4˝).
Material
Certifications
Nylon 6/6
Recognized under the Component Program of Underwriters’ Laboratories
File E121095 (Snap-in Hubs)
UL Listed under Underwriters’ Laboratories File E28430 (NPT Hubs)
94V-2
-22°F (-30°C) to 221°F (105°C)
Flammability Rating
Temperature Range
2-13
1-800-526-4182 • 732-286-1800 (NJ) • FAX: 732-244-8843 • www.heyco.com
I'm thinking of buying an oscilloscope recently, let's discuss it.
I haven't been to the forum for a long time. I've been free recently, so I came here to hang out and get to know everyone, hehe... I don't have an oscilloscope, and I want to buy one recently. I've al...
RF-刘海石 RF/Wirelessly
【Contribute to C2000】Design of a small navigation computer system based on TMS320F28335
Design of Small Navigation Computer System Based on TMS320F28335...
0212009623 Microcontroller MCU
There is no comparison between having a plate and having one!
There is no comparison between having a plate and having one! 1. The investment in diskless is not worthwhile, and now IDE\Stat hard disks are not expensive. Diskless also requires expensive servers. ...
wo2000ailuo PCB Design
(Must read for Ubuntu development) Talk about starting up after burning Ubuntu on E9 card computer
The Ubuntu system of the E9 card computer shares a uboot with the Android system. The default boot mode of uboot is the LCD display mode of the Android system. After burning with MFG tools or SD card,...
小小宇宙 ARM Technology
Analyze this picture
StartFragmentPlease advise me on the functions of the various components in this amplifier. Thank you very much....
lrleizaixian Analog electronics
2410 Dual-host USB driver development
2410 has 2 master USBs and one slave USB. When the slave USB is not in use, there is a switch that can be switched to the master USB. Now one master USB can be used, and the other master USB can also ...
springsky1984 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2105  2589  1924  295  109  43  53  39  6  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号