EEWORLDEEWORLDEEWORLD

Part Number

Search

82502 877U500

Description
Multi-Paired Cables 24AWG 2PR SHIELD 500ft BOX NATURAL
CategoryWire/cable   
File Size87KB,2 Pages
ManufacturerBelden Wire & Cable
Environmental Compliance
Download Datasheet Parametric View All

82502 877U500 Overview

Multi-Paired Cables 24AWG 2PR SHIELD 500ft BOX NATURAL

82502 877U500 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerBelden Wire & Cable
Product CategoryMulti-Paired Cables
RoHSDetails
TypeNetworking
Number of Conductors4 Conductor
Number of Pairs2
Wire Gauge - AWG24 AWG
Stranding7 x 32
Conductor MaterialTinned Copper
Outside Diameter4.11 mm
Jacket MaterialLow Smoke Polyvinyl Chloride (LS PVC)
Length500 ft
ShieldingShielded
FeaturesLow capacitance computer cable used in EIA RS-232 applications
Insulation MaterialFluorinated Ethylene Propylene (FEP)
Jacket ColorNatural
Voltage Rating300 V
Factory Pack Quantity1
Unit Weight8 lbs
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
82502 Multi-Conductor - Computer Cable for EIA RS-232 Applications
For more Information
please call
1-800-Belden1
General Description:
24 AWG stranded (7x32) tinned copper conductors, plenum, FEP insulation, twisted pair, overall Beldfoil
shield (100% coverage), 24 AWG stranded TC drain wire, Flamarrest® jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
2
24
7x32
TC - Tinned Copper
4
Total Number of Conductors:
Insulation
Insulation Material:
Insulation Material
Wall Thickness (in.)
FEP - Fluorinated Ethylene Propylene .006
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
24
7x32
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Flamarrest®
Nom. Wall Thickness (in.)
LS PVC - Low Smoke Polyvinyl Chloride .014
Overall Cable
Overall Nominal Diameter:
0.162 in.
Pair
Pair Color Code Chart:
Number Color
1
2
Black & White
Black & Red
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
0°C To +60°C
14 lbs/1000 ft.
27 lbs.
1.750 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
CMP
CMP
Yes
Yes
Yes
Yes
04/01/2005
Yes
Page 1 of 2
09-11-2017

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2353  1935  745  2109  1582  48  39  15  43  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号