EEWORLDEEWORLDEEWORLD

Part Number

Search

Z-15GQ21A55-B5V

Description
Basic / Snap Action Switches BASIC SWITCH
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size7MB,29 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance
Download Datasheet Parametric View All

Z-15GQ21A55-B5V Online Shopping

Suppliers Part Number Price MOQ In stock  
Z-15GQ21A55-B5V - - View Buy Now

Z-15GQ21A55-B5V Overview

Basic / Snap Action Switches BASIC SWITCH

Z-15GQ21A55-B5V Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerOMRON
Product CategoryBasic / Snap Action Switches
RoHSDetails
Contact FormSPDT
Switch FunctionON - (OFF), OFF - (ON)
ActuatorRoller Plunger
Current Rating15 A
Voltage Rating AC250 VAC
Voltage Rating DC250 VDC
Operating Force5 N
Termination StyleScrew
MountingPanel
IlluminatedNon-Illuminated
Factory Pack Quantity1
Unit Weight1.587328 oz
General-purpose Basic Switch
Z
CSM_Z_DS_E_4_4
Best-selling Basic Switch Boasting
High Precision and Wide Variety
• A large switching capacity of 15 A with high repeat accuracy.
• A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
• A series of standard models for micro loads is available.
• A series of molded terminal-type models incorporating safety
terminal protective cover is available.
Be sure to read
Safety Precautions
on page 26 and
Safety Precautions
for All Basic Switches.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Configuration
Basic models
General-purpose
Drip-proof
Without terminal protective cover
With terminal protective cover
Molded terminal
Split-contact models
Maintained-contact models
General-purpose
General-purpose
Refer to page 3.
Refer to page 5.
Refer to page 5.
Refer to page 2.
Refer to page 4.
Refer to page 4.
Basic Models
General-purpose
A variety of actuators is available for a wide range of application.
The contact mechanism of models for micro loads is a crossbar
type with gold-alloy contacts, which ensures highly reliable
operations for micro loads.
Contact Gap:
H2: 0.20 mm (extra-high-sensitivity)
H: 0.25 mm (high-sensitivity, micro voltage current load)
G: 0.5 mm (standard)
E: 1.8 mm (high-capacity)
Split-contact Models
This type is identical in construction to the general-purpose basic
switch except that it has two pairs of simultaneous acting contacts
by splitting moving contacts.
Since the moving contacts are connected to a common terminal,
either parallel or series connection is possible.
Highly reliable micro load switching is ensured if the model is used
as a twin-contact switch.
Maintained-contact Models
The maintained-contact type has a reset button at the bottom of the
switch case, in addition to the pushbutton (plunger) located on the
opposite side of the reset button. Use these buttons alternately.
Since the Switch has greater pretravel than overtravel, it is suitable
for use in reversible control circuits, manual reset circuits, safety
limit circuits, and other circuits which are not preferable for
automatic resetting. (For further details, refer to individual
datasheets.)
Drip-proof
These Switches use a rubber boot on the actuator and adhesive fill
between the case and cover to increase resistance to drips.
Models with drip-proof terminal protective covers and molded
terminals with resin filling are also available.
1
[Xianji HPM6750 Review] Testing the Ethernet Controller ENET
HPM6750 has 2 Gigabit Ethernet controllers. The MINI board leads to a RMII interface Ethernet controller HPM_ENET1 PIN. There is a lwip tcpecho routine in the SDK. The default PHY used is DP83848. I r...
xiashuang Domestic Chip Exchange
Help: The no-load current of LM5122 is very large and it is always running at full duty cycle. What could be the reason?
Help: The no-load current of LM5122 is very large and it is always running at full duty cycle. What could be the reason?...
blink Analogue and Mixed Signal
Waveform Amplitude Step
What methods can be used to achieve a 0.1V step for the wave amplitude (between 0 and 5V)?...
吖辉 Analog electronics
Designing a compact, efficient and high-performance multi-parameter patient monitor
Continuously measuring patient vital signs such as heart rate, respiratory rate and blood oxygen saturation (SpO2) is critical to providing effective care, and the ability to measure these signs simul...
alan000345 TI Technology Forum
Please provide information about zrtech's PERII_8KD
I'm begging for the information of zrtech's PERII_8KD. Thank you, everyone....
a972043362 FPGA/CPLD
The component is not highlighted when AD10 moves the silk screen
When I first started installing, the PCB mobile silkscreen components would be highlighted so that I could easily know which part the silkscreen was. Now it is not highlighted. How can I set it up? Is...
liaoqiwen PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1864  2695  2316  2138  971  38  55  47  44  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号