THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
80D
www.vishay.com
Vishay Sprague
NOMINAL CASE SIZE
DxL
1.18 x 1.38 (30.0 x 35.0)
1.38 x 1.38 (35.0 x 35.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 1.57 (25.0 x 40.0)
1.18 x 1.18 (30.0 x 30.0)
1.18 x 1.57 (30.0 x 40.0)
1.18 x 1.97 (30.0 x 50.0)
0.984 x 1.18 (25.0 x 30.0)
1.18 x 1.18 (30.0 x 30.0)
1.38 x 1.18 (35.0 x 30.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 1.18 (25.0 x 30.0)
1.18 x 1.18 (30.0 x 30.0)
0.984 x 1.97 (25.0 x 50.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 0.984 (25.0 x 25.0)
1.18 x 0.984 (30.0 x 25.0)
1.18 x 1.38 (30.0 x 35.0)
1.18 x 1.57 (30.0 x 40.0)
1.18 x 1.57 (30.0 x 40.0)
1.38 x 1.97 (35.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 0.984 (25.0 x 25.0)
0.984 x 1.18 (25.0 x 30.0)
0.984 x 1.57 (25.0 x 40.0)
0.984 x 1.97 (25.0 x 50.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
MAX. ESR (m)
MAX. RIPPLE AT +85 °C (A)
10 kHz TO 40 kHz
4.2
7.2
7.2
10.0
4.9
3.6
4.9
6.1
3.8
3.9
6.6
6.4
10.0
3.5
3.7
5.9
6.2
6.2
3.2
3.6
4.9
5.7
4.7
7.4
6.6
6.6
3.2
3.8
5.2
6.3
7.0
7.4
ELECTRICAL DATA AND ORDERING INFORMATION
CAPACITANCE (μF)
PART NUMBER
120 Hz 10 kHz TO 40 kHz 120 Hz
60.0
33.0
33.0
20.0
57.0
79.0
51.0
40.0
82.0
72.0
40.0
36.0
21.0
139.0
111.0
68.0
55.0
50.0
660.0
460.0
278.0
220.0
248.0
130.0
144.0
141.0
720.0
541.0
343.0
263.0
185.0
191.0
51.0
27.0
27.0
17.0
42.0
63.0
41.0
32.0
55.0
54.0
28.0
28.0
15.0
85.0
74.0
42.0
37.0
37.0
375.0
272.0
165.0
131.0
127.0
82.0
81.0
75.0
377.0
284.0
182.0
140.0
101.0
81.0
3.8
6.2
6.2
8.8
3.9
3.1
4.3
5.3
2.8
3.2
5.0
5.4
8.3
2.2
2.7
3.9
4.7
5.2
1.3
1.7
2.4
2.8
2.1
4.3
3.4
3.4
1.1
1.4
2.0
2.5
3.2
4.0
35 WV
DC
AT +85 °C, SURGE = 44 V
6800.0
10 000.0
12 000.0
15 000.0
3300.0
3300.0
4700.0
6800.0
1500.0
2200.0
3300.0
4700.0
6800.0
680.0
1000.0
1500.0
2200.0
3300.0
150.0
220.0
330.0
470.0
680.0
820.0
1000.0
1200.0
100.0
150.0
220.0
330.0
470.0
680.0
Statements about product lifetime are based on calculations and internal testing. They should only be interpreted as estimations. Also due to external factors, the
lifetime in the field application may deviate from the calculated lifetime. In general, nothing stated herein shall be construed as a guarantee of durability.
80D682P035KC2DE3
80D103P035MC2DE3
80D123P035KE2DE3
80D153P035ME2DE3
80D332P050JD2DE3
80D332P050KB2DE3
80D472P050KD2DE3
80D682P050KE2DE3
80D152P063JB2DE3
80D222P063KB2DE3
80D332P063MB2DE3
80D472P063KE2DE3
80D682P063ME2DE3
80D681P100JB2DE3
80D102P100KB2DE3
80D152P100JE2DE3
80D222P100KE2DE3
80D332P100ME2DE3
80D151P200JA2DE3
80D221P200KA2DE3
80D331P200KC2DE3
80D471P200KD2DE3
80D681P200KD2DE3
80D821P200ME2DE3
80D102P200ME2DE3
80D122P200ME2DE3
80D101P250JA2DE3
80D151P250JB2DE3
80D221P250JD2DE3
80D331P250JE2DE3
80D471P250KE2DE3
80D681P250ME2DE3
50 WV
DC
AT +85 °C, SURGE = 63 V
63 WV
DC
AT +85 °C, SURGE = 79 V
100 WV
DC
AT +85 °C, SURGE = 125 V
200 WV
DC
AT +85 °C, SURGE = 250 V
250 WV
DC
AT +85 °C, SURGE = 300 V
Revision: 20-Jul-16
Document Number: 42060
3
For technical questions, contact:
aluminumcaps4@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Modbus protocol has become the first choice of communication protocol in the current industrial field due to its openness, transparency, low cost and easy development. This paper introduces a communi...
[img]http://www.oldzhang.com/keti/hongwaitgd/shiwu2.jpg[/img]:funk: [align=center][size=+2][b]Design of infrared remote control dimming lamp controller[/b][/size][/align] [size=+1][b]I. Tasks and requ...
I am not a person who likes to show off. But I have to show this. Because I remember working early to weld the plate and pass it in one go and won a prize. I took a picture of it a long time ago, I th...
This is my first time using OLEDB and I don't know how to get started. Can someone give me a rough idea of the process? Or a simple example? QQ9737964 E-MAIL:lmj1912@163.com...
Environment description: CubeSuites+ Since the environment does not support Chinese, it brings a lot of trouble to the readability of the program. When you have free time, you can list the peripheral ...
Validity period: From now until February 20, 2020Dear forum friends:
Happy New Year. In 2020, the community intends to improve the user experience of the live broadcast room. What new features do you ...
As the number of cars increases, environmental pressures are also increasing. At this time, some people are saying that new energy vehicles are energy-efficient and environmentally friendly, and ar...[Details]
Limited vocabulary recognition
According to the number of characters, words or short sentences in the vocabulary, it can be roughly divided into: less than 100 is small vocabulary; 100-1000 is...[Details]
Recently,
Xpeng Motors and Xinlian Integrated Circuit jointly announced the mass production of China's first hybrid silicon carbide product.
Designed and developed by Xpeng Motors and joint...[Details]
Permanent magnets are essential components in a wide range of household and industrial devices. They are particularly crucial in the renewable energy sector, including electric vehicle motors. Curr...[Details]
The 2025 China International Automotive Testing Exhibition will be held at the Shanghai World Expo Exhibition and Convention Center from August 27 to 29, 2025.
Clacton Seafront, UK, ...[Details]
1. Fault phenomenon and cause analysis
1. During the operation of the equipment, the expansion sleeve is subjected to a large torque, and the mating surfaces of the shaft and the sleeve move...[Details]
In the field of communications power supplies, AC/DC rectifier power supplies are called primary power supplies or basic power supplies, while DC/DC converters are called secondary power supplies. ...[Details]
As the range of electric vehicles continues to increase, driving electric vehicles for long-distance travel has become a trend. For high-speed travel, how much impact will high-speed driving of ele...[Details]
Speaking of the problem of vehicle spontaneous combustion, whether it is a pure electric vehicle or a fuel vehicle, there will be incidents of spontaneous combustion. For the same spontaneous combu...[Details]
01. Introduction
As in-vehicle networks migrate from the CAN
bus
to
Ethernet
, traditional millisecond-level synchronization accuracy can no longer meet the requirements of mul...[Details]
On August 18th, China's largest expressway
charging station,
the G25 Changshen Expressway Tonglu Service Area (South Area), officially opened and launched its integrated solar-storage-charg...[Details]
Lithium-ion batteries are a key component of electric vehicles. Their high energy density enables them to store a large amount of energy in a relatively compact and lightweight package, which is cr...[Details]
Renesas Electronics introduces a new USB-C power solution with an innovative three-level topology.
Improve performance while reducing system size
New solution combines excel...[Details]
01 Introduction
The SINAMICS V20 inverter controls three-phase AC asynchronous motors. Depending on the size (frame sizes FSA to FSD), the power range of the three-phase AC 400V inverter cover...[Details]
From August 8 to 12, 2025, the highly anticipated 2025 World Robotics Conference (WRC) will be held at the Beiren Yichuang International Convention and Exhibition Center in the Beijing Economic and...[Details]