EEWORLDEEWORLDEEWORLD

Part Number

Search

805-004-02-ZNU9-1SA

Description
Circular Connector, 1 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,
CategoryThe connector   
File Size485KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

805-004-02-ZNU9-1SA Overview

Circular Connector, 1 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,

805-004-02-ZNU9-1SA Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
Is SamacsysN
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact point genderFEMALE
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceZINC-NICKEL WITH CHROMATE PLATED
Shell materialALUMINUM ALLOY
Housing size9
Termination typeCRIMP
Total number of contacts1
Base Number Matches1
A
B
C
D
E
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
Series 805
Series 805 “Mighty Mouse”
Triple-Start
Series 805 Receptacles
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, square flange for front
or rear panel mounting, or in-line
receptacles for free-hanging cables.
Two Shell Styles:
Choose
integral
band platform
for direct attachment
of a cable shield. Install a boot,
or overmold a boot over the band
platform.
Gold-Plated Crimp Contacts
are held in place with beryllium
copper retention clips. Contacts are
removable.
Series 805 Triple-Start
Jam Nut Connector
An
accessory thread
is available
for attaching strain reliefs and
backshells.
HOW TO ORDER
Sample Part Number
80 5- 0 0 4
Series
-02
Shell Style
NF
Shell Material /
Finish
C
Aluminum / Black
Anodize
9-10
Shell Size- Insert
Arrangement
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
15-37
37 #23 Contacts
18-55
55 #23 Contacts
19-85
85 #23 Contacts
Size #23 contacts are
supplied with connectors.
Other contact sizes are
ordered separately.
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
A
Shell Key
Position
A
Position A
(Normal)
M
-01
805-003
Receptacle with
Banding Platform
In-Line
Aluminum / Electroless
Nickel
NF
Aluminum / Cadmium
with Olive Drab
Chromate
8-1
8-4
8-7
9-1
9-10
10-13
11-4
11-19
12-26
15-2
B
Position B
P
Pin
C
Position C
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
D
Position D
ZN
-02
Square Flange
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
805-004
Receptacle with
Accessory Thread
-07
Jam Nut for Rear
Panel Mounting
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
H-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
MAX32630FTHR-A human pulse respiratory rate and blood oxygen concentration online monitoring system
[size=5][font=微软雅黑](1) Title of the work: [/font] [font=微软雅黑][b]A human pulse, respiratory rate and blood oxygen concentration online monitoring system [/b] [/font] [font=微软雅黑](2) Introduction to the ...
Justice_Gao DIY/Open Source Hardware
Help: Click a button in VC to update the dll file in the specified directory
I would like to ask all the experts, how to create a dialog box and click the command button in it to update the dll file in the specified directory. I hope you can give me some advice, thank you!...
yph321 Embedded System
How to correctly select the integrated circuit (IC) of the power supply in power supply design
Choosing the right integrated circuit (IC) for a power supply may seem like a piece of cake on the surface. However, this task has become increasingly complex with the introduction of consumer electro...
qwqwqw2088 Analogue and Mixed Signal
I am very anxious. Can someone help me write a program for the DIP switch input and then the pulse frequency division?
The 8-bit DIP switch goes from 0000 0000 to 1111 1111 00000000 is no frequency division,,, 00000001 is 2 frequency division,, and so on until 11111111.. Who can help me write it down,,, I am very anxi...
eeleader FPGA/CPLD
Electronic Design Competition High Frequency Direction
[i=s]This post was last edited by paulhyde on 2014-9-15 09:07[/i] Does anyone have some high frequency data to provide? ?...
hpfei77 Electronics Design Contest
How to ensure the accuracy of PCB circuit board milling
The milling technology of PCB circuit board CNC milling machine includes the selection of cutting direction, compensation method, positioning method, frame structure, and cutting point. These are all ...
ESD技术咨询 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1232  2843  1573  2236  539  25  58  32  46  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号