Alpha Wire | 711 Lidgerwood Avenue, Elizabeth, NJ 07207
Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com
Customer Specification
PART NO. V16114
Construction
Diameters (In)
1) Component 1
a) Conductor
b) Insulation
(1) Separator
(2) Color(s)
Cond
1
2
2) Component 2
a) Conductor
b) Insulation
(1) Separator
(2) Color(s)
Pair
1
c) Pair
(1) Twists:
Individually Applied:
d) Shield:
(1) Foil Direction
(2) Drain Wire
3) Cable Assembly
a) Twists:
4) Shield:
a) Drain Wire
b) Braid
5) Jacket
a) Color(s)
b) Jacket Separator
Alum/Mylar Tape, 25% Overlap, Min.
Foil Facing In
14 (41/30) AWG TC
5 Components Cabled
1.7 Twists/foot (min)
A/P/A Tape, 25% Overlap, Min.
14 (41/30) AWG TC
TC,85% Coverage, Min.
0.065" Wall, Nom.,PVC
BLACK
Tissue Tape, 25% Overlap, Min.
ALPHA WIRE- E64067-L P/N V16114 4/C 14 AWG RHW-2
1PR 14 AWG XHHW-2 SERIES V VFD CABLE W/ BRAKE PAIR
600V TYPE TC-ER (UL) XLPE/PVC 90C DRY/WET SUN RES
DIR BUR 4/C 14 AWG 1PR 14 AWG--- LLXXXXXX CSA AWM
I/II A/B 1000V 90C FT4 --- CE ROHS
[Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.]
0.743+/- 0.026
Color
BLACK-WHITE
2/Cond Cabled Together
2.8 Twists/foot (min)
Pair
Color
Pair
Color
Color
BLACK#1
BLACK#2
Cond
3
4
1 X 1 PAIR
14 (41/30) AWG TC
0.032" Wall, Nom. XLPE
Paper Tape, 10% Overlap, Min.
0.075
0.142
Color
BLACK#3
GREEN OR
GREEN/YELLOW
Cond
Color
4 X 1 COND
14 (41/30) AWG TC
0.047" Wall, Nom. XLPE
Paper Tape, 10% Overlap, Min.
0.074
0.171
c) Print
Applicable Specifications
1) UL
a) Component 1
RHW-2Wet/Dry
XHHW-2Wet/Dry
b) Component 2
c) Overall
XHHW-2Wet/Dry
TC
EXPOSED RUN
DIRECT BURIAL
SUN RES
2) CSA International
a) Component 1
b) Component 2
c) Overall
AWM I A/B
AWM I A/B
AWM I/II A/B
FT4
3) CE:
LVD 73/23/EEC Amendment 93/68/EEC
90°C / 1000 VRMS
90°C / 1000 VRMS
90°C / 1000 VRMS
90°C / 600 VRMS
90°C / 600 VRMS
90°C / 600 V
RMS
90°C / 600 VRMS
Environmental
1) EU Directive 2002/95/EC(RoHS):
All materials used in the manufacture of this part are in compliance with EU Directive
2002/95/EU regarding the restriction of use of certain hazardous substances in electrical and
electronic equipment. Consult Alpha Wire's web site for compliance Date of Manufacture.
Properties
Physical & Mechanical Properties
1) Temperature Range
2) Bend Radius
3) Pull Tension
4) Sunlight Resistance
5) Direct Burial
Electrical Properties
1) Voltage Rating
2) Component 1
a) Characteristic Impedance
b) Inductance
c) Mutual Capacitance
d) Ground Capacitance
e) Conductor DCR
f) OA Shield DCR
g) Current
h) Insulation Resistance
3) Component 2
a) Inductance
b) Mutual Capacitance
c) Ground Capacitance
d) Conductor DCR
e) Ind. Shield DC Resistance
f) Current
g) Insulation Resistance
0.19 µH/ft, Nominal
22 pf/ft @1 kHz, Nominal
40 pf/ft @1 kHz, Nominal
2.6 /1000ft @20°C, Nominal
2.45 /1000ft @20°C, Nominal
20 amps per conductor @30°C, Maximum
300 M/MFt (Est.)
45
0.21 µH/ft, Nominal
40 pf/ft @1 kHz, Nominal
70 pf/ft @1 kHz, Nominal
2.8 /1000ft @20°C, Nominal
0.95 /1000ft @20°C, Nominal
20 amps per conductor @30°C, Maximum
300 M/MFt (Est.)
-40 to 90°C
10X Cable Diameter
273 Lbs, Maximum
Yes
Yes
(For Engineering purposes only)
1000 V
RMS
Other
Packaging
a) Bulk(Made-to-order)
Flange x Traverse x Barrel (inches)
www.alphawire.com
Alpha Wire | 711 Lidgerwood Avenue, Elizabeth, NJ 07207
Tel: 1-800-52 ALPHA (25742)
Although Alpha Wire (“Alpha”) makes every reasonable effort to ensure there accuracy at the time of publication, information and specifications
described herein are subject to errors or omissions and to changes without notice, and the listing of such information and specifications does not
ensure product availability.
Alpha provides the information and specifications herein on an “AS IS” basis, with no representations or warranties, whether express, statutory or
implied. In no event will Alpha be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary) whatsoever,
even if Alpha had been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out
of or in connection with the use, or inability to use, the information or specifications described herein.
Alpha Wire | 711 Lidgerwood Avenue, Elizabeth, NJ 07207
Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com
RoHS CERTIFICATE OF COMPLIANCE
To Whom It May Concern:
Alpha Wire Part Number:V16114
V16114 , RoHS-Compliant Commencing With10/1/2005Production
This document certifies that the Alpha part numbers cited above are manufactured in accordancewith Directive 2002/95/EC of the European
Parliament and of the Council of 27 January 2003,better known as the RoHS Directives, with regards to restrictions of the use of certain
hazardoussubstances used in the manufacture of electrical and electronic equipment. The reader is referredto these Directives for the specific
definitions and extents of these Directives.
No Exemptions arerequired for RoHS Compliance on this item.
Substance
Lead
Mercury
Cadmium
Hexavalent Chromium
Polybrominated Biphenyls (PBB)
Polybrominated Diphenyl Ethers (PBDE)
Including Deca-BDE
Maximum Control Value
0.1% by weight (1000 ppm)
0.1% by weight (1000 ppm)
0.01% by weight (100 ppm)
0.1% by weight (1000 ppm)
0.1% by weight (1000 ppm)
0.1% by weight (1000 ppm)
The information provided in this document and disclosure is correct to the best of Alpha Wire'sknowledge, information and belief at the date of its
release. The information provided is designedonly as a general guide for the safe handling, storage, and any other operation of the productitself or
the one that it will become part of. The intent of this document is not to be considered awarranty or quality specification. Regulatory information is
for guidance purposes only. Productusers are responsible for determining the applicability of legislation and regulations based ontheir individual
usage of the product.
Authorized Signatory for the Alpha Wire Company:
Dave Watson, Director of Engineering & QA
11/2/2012