EEWORLDEEWORLDEEWORLD

Part Number

Search

8105 060500

Description
Multi-Paired Cables 24AWG 5PR SHIELD 500ft SPOOL CHROME
CategoryWire/cable   
File Size162KB,3 Pages
ManufacturerBelden Wire & Cable
Environmental Compliance
Download Datasheet Parametric Compare View All

8105 060500 Overview

Multi-Paired Cables 24AWG 5PR SHIELD 500ft SPOOL CHROME

8105 060500 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerBelden Wire & Cable
Product CategoryMulti-Paired Cables
Shipping RestrictionsDue to size or weight of the product, your shipping charge may increase.
RoHSDetails
TypeNetworking
Number of Conductors10 Conductor
Number of Pairs5
Wire Gauge - AWG24 AWG
Stranding7 x 32
Conductor MaterialTinned Copper
Outside Diameter8.03 mm
Jacket MaterialPolyvinyl Chloride (PVC)
Length500 ft
ShieldingShielded
FeaturesLow capacitance computer cable used in EIA RS-232 and RS-422 applications
Insulation MaterialFoam Polyethylene (FPE)
Jacket ColorChrome
Voltage Rating30 V
Factory Pack Quantity1
Unit Weight25 lbs
Part Number:
8105
RS-232/422 Low Cap, #24-5pr, FPO, O/A Foil+Braid, PVC Jkt, CM, 100Ω
Product Description
Computer EIA RS-232/422 Cable, 24 AWG stranded (7x32) tinned copper conductors, Datalene® insulation, twisted pairs, overall Beldfoil® (100% coverage) +
tinned copper braid shield (65% coverage), 24 AWG stranded tinned copper drain wire, PVC jacket.
Technical Specifications
Physical Characteristics (Overall)
Conductor
AWG Stranding
24
7x32
Material
No. of Conductors No. of Pairs
5
10
24 AWG
TC - Tinned Copper 10
Conductor Count:
Conductor Size:
Insulation
Material
Material Trade Name Nominal Wall Thickness
0.013 in
FPE - Foamed Polyethylene Datalene®
Color Chart
Number
1
2
3
4
5
Color
White/Blue & Blue/White
White/Orange & Orange/White
White/Green & Green/White
White/Brown & Brown/White
White/Gray & Gray/White
Outer Shield Material
Type Layer
Tape 1
Braid 2
Material
Material Trade Name Coverage [%] Drainwire Material
100 %
65 %
Drainwire AWG Drainwire Construction n x D
7x32 mm
Aluminum Foil-Polyester Tape w/Shorting Fold Beldfoil®
TC - Tinned Copper
TC - Tinned Copper 24
Outer Jacket Material
Material
Nominal Diameter Nominal Wall Thickness
0.035 in
PVC - Polyvinyl Chloride 0.303 in
Electrical Characteristics
Conductor DCR
Nominal Conductor DCR Nominal Outer Shield DCR
24 Ohm/1000ft
Capacitance
Nom. Capacitance Conductor to Conductor Nom. Capacitance Conductor to Other Conductor to Shield
12.5 pF/ft
Shielding:
Impedance
Nominal Characteristic Impedance
100 Ohm
22 pF/ft
Foil + Braid(s)
4.2 Ohm/1000ft

8105 060500 Related Products

8105 060500 8105 060100
Description Multi-Paired Cables 24AWG 5PR SHIELD 500ft SPOOL CHROME Multi-Paired Cables 24AWG 5PR SHIELD 100ft SPOOL CHROME
Product Attribute Attribute Value Attribute Value
Manufacturer Belden Wire & Cable Belden Wire & Cable
Product Category Multi-Paired Cables Multi-Paired Cables
RoHS Details Details
Type Networking Networking
Number of Conductors 10 Conductor 10 Conductor
Number of Pairs 5 5
Wire Gauge - AWG 24 AWG 24 AWG
Stranding 7 x 32 7 x 32
Conductor Material Tinned Copper Tinned Copper
Outside Diameter 8.03 mm 8.03 mm
Jacket Material Polyvinyl Chloride (PVC) Polyvinyl Chloride (PVC)
Length 500 ft 100 ft
Shielding Shielded Shielded
Features Low capacitance computer cable used in EIA RS-232 and RS-422 applications Low capacitance computer cable used in EIA RS-232 and RS-422 applications
Insulation Material Foam Polyethylene (FPE) Foam Polyethylene (FPE)
Jacket Color Chrome Chrome
Voltage Rating 30 V 30 V
Factory Pack Quantity 1 1
Unit Weight 25 lbs 5.200 lbs
Can someone give me an example of sending MMS using GPRS modem. Written in C++, I'd be grateful
Can anyone give me an example of sending MMS using GPRS modem? Written in C++, I'd be grateful. It includes connecting to the network and sending MMS. If you can solve this problem, I'd give you 1000 ...
bingfo Embedded System
Or is it the ADC problem?
I used a potentiometer to get a voltage through resistor voltage division and connected it to the analog input port. I found that when adjusting the potentiometer, the voltage did not change evenly an...
greatdoor stm32/stm8
Share a wave of DIY reference designs for the Internet of Things
I just saw a netizen share an IoT design in our forum. I'd like to share it with you to provide you with some ideas. Welcome everyone to participate in the IoT Creative Design Competition in cooperati...
okhxyyo RF/Wirelessly
Can I use the release version of NK to debug the debug version of the driver?
Can I put the debug driver into the release directory, then makeimg, and set the release version to enable kernel debugger, enable kitl? Why can I breakpoint after doing this, but the variable value i...
djf876 Embedded System
I would like to ask a question about the sampling rate of MSP430 ADC12
[i=s] This post was last edited by Ben who hates bitter coffee on 2015-4-20 09:43 [/i] I have always been confused about the ADC12 sampling rate. Today I hope someone can help me answer it. I read in ...
Ben讨厌苦咖啡 Microcontroller MCU
Sensor Recommendation
[align=left]Problem description:[/align][align=left]The globe can rotate 360 degrees. One or more sensors are installed on the globe to meet the following conditions:[/align][align=left]No matter how ...
leichris0429 Integrated technical exchanges

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 780  36  1242  592  585  16  1  25  12  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号