SIDACtor®
Device
RoHS
This modified TO-220 package with Type 61 lead spacing offers a through-hole technology
SIDACtor
protection solution.
SIDACtor
devices enable equipment to comply with various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A
(formerly known as FCC Part 68).
Electrical Parameters
Part
Number *
P2000AA61L
P2200AA61L
P2400AA61L
P2500AA61L
P3000AA61L
P3300AA61L
V
DRM
Volts
180
200
220
240
270
300
V
S
Volts
220
240
260
290
330
360
V
T
Volts
4
4
4
4
4
4
I
DRM
µAmps
5
5
5
5
5
5
I
S
mAmps
800
800
800
800
800
800
I
T
Amps
2.2
2.2
2.2
2.2
2.2
2.2
I
H
mAmps
150
150
150
150
150
150
*
“L” in part number indicates RoHS compliance.
For non-RoHS compliant device, delete “L” from part number.
For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. I
PP
applies to -40 °C through +85 °C temperature range.
• I
PP
is a repetitive surge rating and is guaranteed for the life of the product.
• Listed
SIDACtor
devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• V
DRM
is measured at I
DRM.
• V
S
is measured at 100 V/µs.
• Special voltage (V
S
and V
DRM
) and holding current (I
H
) requirements are available upon request.
Surge Ratings in Amps
I
PP
Series
0.2x310 * 2x10 *
8x20 *
0.5x700 ** 2x10 ** 1.2x50 **
Amps
A
20
Amps
150
Amps
150
10x160 *
10x160 **
Amps
90
10x560 *
10x560 **
Amps
50
5x320 *
9x720 **
Amps
75
10x360 * 10x1000 * 5x310 *
I
TSM
10x360 ** 10x1000 ** 10x700 ** 50 / 60 Hz
Amps
75
Amps
45
Amps
75
Amps
20
di/dt
Amps/µs
500
* Current waveform in µs
** Voltage waveform in µs
Telecom Design Guide • © 2006 Littelfuse
3 - 43
www.littelfuse.com
SIDACtor Devices
SIDACtor® Device
Thermal Considerations
Package
Modified
TO-220
Type 61
Symbol
T
J
T
S
R
θJA
Parameter
Operating Junction Temperature Range
Storage Temperature Range
Thermal Resistance: Junction to Ambient
Value
-40 to +150
-65 to +150
50
Unit
°C
°C
°C/W
Capacitance Values
pF
Part Number
P2000AA61L
P2200AA61L
P2400AA61L
P2500AA61L
P3000AA61L
P3300AA61L
MIN
25
25
25
20
20
20
MAX
35
35
35
35
35
35
Note: Off-state capacitance (C
O
) is measured at 1 MHz with a 2 V bias.
+I
I
PP
– Peak Pulse Current – %I
PP
I
T
I
S
I
H
I
DRM
-V
V
T
V
DRM
V
S
+V
100
Peak
Value
t
r
= rise time to peak value
t
d
= decay time to half value
Waveform = t
r
x t
d
50
Half Value
0
0
-I
t
r
t
d
t – Time (µs)
V-I Characteristics
14
12
10
8
6
4
2
0
-4
-6
-8
-40 -20
0
20 40 60 80 100 120 140 160
t
r
x t
d
Pulse Waveform
Percent of V
S
Change – %
I
H
(T
C
= 25 ˚C)
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
-40 -20 0
20 40 60 80 100 120 140 160
I
H
25 ˚C
25 ˚C
Ratio of
Junction Temperature (T
J
) – ˚C
Normalized V
S
Change versus Junction Temperature
Case Temperature (T
C
) – ˚C
Normalized DC Holding Current versus Case Temperature
www.littelfuse.com
3 - 44
© 2006 Littelfuse • Telecom Design Guide
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Littelfuse
:
P3300AA61L P2400AA61L P2000AA61L P2200AA61L P2500AA61L P3000AA61L P3300AA61 P2500AA61
P2200AA61 P2000AA61 P2400AA61 P3000AA61 P3000AA61LRP P3000AA61RP