EEWORLDEEWORLDEEWORLD

Part Number

Search

MKS4F021002B00MJ00

Description
Film Capacitor, Polyethylene Terephthalate, 250V, 20% +Tol, 20% -Tol, 0.01uF, Through Hole Mount, RADIAL LEADED
CategoryPassive components    capacitor   
File Size429KB,12 Pages
ManufacturerWIMA
Websitehttps://www.wima.de/
Download Datasheet Parametric View All

MKS4F021002B00MJ00 Online Shopping

Suppliers Part Number Price MOQ In stock  
MKS4F021002B00MJ00 - - View Buy Now

MKS4F021002B00MJ00 Overview

Film Capacitor, Polyethylene Terephthalate, 250V, 20% +Tol, 20% -Tol, 0.01uF, Through Hole Mount, RADIAL LEADED

MKS4F021002B00MJ00 Parametric

Parameter NameAttribute value
Objectid145071110834
package instruction,
Reach Compliance Codecompliant
Country Of OriginGermany
ECCN codeEAR99
YTEOL6.35
capacitance0.01 µF
Capacitor typeFILM CAPACITOR
dielectric materialsPOLYETHYLENE TEREPHTHALATE
high8.5 mm
JESD-609 codee3
length10 mm
Installation featuresTHROUGH HOLE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formRadial
method of packingTR, 20 INCH
positive tolerance20%
Rated (AC) voltage (URac)160 V
Rated (DC) voltage (URdc)250 V
GuidelineAEC-Q200
surface mountNO
Terminal surfaceTIN
Terminal pitch7.5 mm
Terminal shapeWIRE
width3 mm
WIMA MKS 4
Metallized Polyester (PET) Capacitors
in PCM 7.5 mm to 52.5 mm. Capacitances from 1000 pF to 680
mF.
Rated Voltages from 50 VDC to 2000 VDC.
Special Features
˜
High volume/capacitance ratio
˜
Self-healing
˜
According to RoHS 2011/65/EU
D
Electrical Data
Capacitance range:
1000 pF to 680
mF
(E12-values on request)
Rated voltages:
50 VDC, 63 VDC, 100 VDC, 250 VDC, 400 VDC,
630 VDC, 1000 VDC, 1500 VDC, 2000 VDC
Capacitance tolerances:
± 20%, ± 10% ± 5%
Operating temperature range:
U
r
= 50 VDC: –55+ C to +100+ C
U
r
63 VDC: –55+ C to +125+ C
Climatic test category:
55/100/56 in accordance with IEC
Insulation resistance
at +20+ C:
U
r
50 VDC
63 VDC
100 VDC
U
test
10 V
50 V
100 V
C
0.33
mF
5
x 10
3
1
x 10
4
1.5
x 10
4
3
x 10
4
Test voltage:
1.6 U
r
, 2 sec.
Test specifications:
In accordance with IEC 60384-2
Voltage derating:
A voltage derating factor of 1.25 % per K
must be applied from +85+ C for DC
voltages and from +75+ C for AC
voltages.
Reliability:
Operational life
300 000 hours (+125° C
permitted for 1000 hours max. distributed
over the entire operating life)
Failure rate
2 fit (0.5 x U
r
and 40) C)
0.33
mF
< C
680
mF
1500
sec (M¸ x
mF)
3000
sec (M¸ x
mF)
5000
sec (M¸ x
mF)
10
000 sec (M¸ x
mF)
Typical Applications
For general DC-applications e.g.
˜
By-pass
˜
Blocking
˜
Coupling and decoupling
˜
Smoothing
˜
Timing
Construction
Dielectric:
Polyethylene-terephthalate (PET) film
Capacitor electrodes:
Vacuum-deposited
Internal construction:
MKS 4: 30 VAC, 40 VAC, 63 VAC, 160 VAC, 200 VAC
Plastic film
Vacuum-deposited
electrode
Metal contact layer
(schoopage)
Terminating wire
250
VDC 100 V
Measuring time: 1 min.
Dissipation factors
at + 20) C: tan
d
at f
1 kHz
10 kHz
100 kHz
C
0.1
mF
8 x 10
-3
15 x 10
-3
30 x 10
-3
0.1
mF
< C
1.0
mF
8 x 10
-3
15 x 10
-3
C > 1.0
mF
10 x 10
-3
Maximum pulse rise time:
for pulses equal to the rated voltage
Capacitance
pF/mF
Pulse rise time V/msec
max. operation/test
50VDC 63VDC 100VDC 250VDC 400VDC 630VDC 1000VDC 1500VDC 2000VDC
10/100
9/90
6/60
2.5/25
2.5/25
2.5/25
2.5/25
0.2/2
30/300
15/150
10/100
9/90
6/60
3/30
2.5/25
2.5/25
2.5/25
0.2/2
30/300
15/150
12/120
9/90
5/50
3/30
2.5/25
2.5/25
2.5/25
0.3/3
35/350
20/200
15/150
10/100
6/60
6/60
3/30
3/30
0.9/9
38/380
25/250
15/150
10/100
9/90
6/60
6/60
3/30
40/400
32/320
17/170
13/130
13/130
9/90
6/60
70/700
50/500
26/260
20/200
20/200
14/140
12/120
6/60
90/900 100/1000
50/500 60/600
35/350 40/400
35/350 40/400
20/200 38/380
15/150 15/150
MKS 4: 400 VAC
Plastic film
Vacuum-deposited
electrode
Metal contact layer
(schoopage)
Terminating wire
Encapsulation:
Solvent-resistant, flame-retardant plastic
case with epoxy resin seal, UL 94 V-0
Terminations:
Tinned wire.
Marking:
Colour: Red. Marking: Black.
Epoxy resin seal: Red
1000
0.01
0.033
0.1
0.33
1.0
3.3
10
33
100
330
...
...
...
...
...
...
...
...
...
...
...
6800
0.022
0.068
0.22
0.68
2.2
6.8
22
68
220
680
Mechanical Tests
Pull test on pins:
d
0.8
l
: 10 N in direction of pins
d > 0.8
l
: 20 N in direction of pins
according to IEC 60068-2-21
Vibration:
6 hours at 10 ... 2000 Hz and
0.75 mm displacement amplitude or 10 g
in accordance with IEC 60068-2-6
Low air density:
1kPa = 10 mbar in
accordance with IEC 60068-2-13
Bump test:
4000 bumps at 390 m/sec
2
in accordance with IEC 60068-2-29
Packing
Available taped and reeled up to and
including case size 15 x 26 x 31.5 /
PCM 27.5 mm.
Detailed taping information and graphs
at the end of the catalogue.
50
04.18
For further details and graphs please
refer to Technical Information.
Sharing the process of WEBENCH design + designing a DC/DC power supply
[color=#555555]WEBENCH Design Environments are unique and powerful software tools that provide custom power, lighting, filtering, clock and sensor designs in just seconds. These easy-to-use tools help...
liwenying Analogue and Mixed Signal
GPS Vehicle Positioning and Monitoring System Based on GSM
Using GPS (Global Positioning System) for positioning and navigation is the most basic application of GPS. With the expansion of urban construction in my country and the increasing number of vehicles,...
frozenviolet Automotive Electronics
Isolation Tips for Protecting Test and Measurement Equipment
[color=#000000][font=宋体][font=Arial][size=2]To obtain higher precision data acquisition capabilities, it is a challenge for test and measurement equipment designers and engineers to measure small sign...
bolibo123 Test/Measurement
Requirements for the mechanical structure of CNC machine tools
In the initial stage of the development of CNC machine tools, their mechanical structure did not change much compared with general machine tools, except for some changes in automatic speed change, aut...
intebank Industrial Control Electronics
How to calculate the frequency of a clock
I have an A/D converter. The hardware manual does not specify the required clock frequency, but gives other information. I don't know how to calculate it. Please help me. Throughput rate 200 ksps, VDD...
ylcmd Embedded System
Regarding the delay issue of traffic light program!!! Urgent!!!!!!!!!
The P control rule is as follows: the green light at the north-south intersection and the red light at the east-west intersection are on at the same time for 30 seconds; the yellow light at the north-...
GPS11 Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1162  426  2010  1256  569  24  9  41  26  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号