Features and Benefits
n
Sizes 2 to 33 circuits
n
Robust blade contacts resist damage from
improper mating
n
Large surface area of dual wipe female
contact produces maximum current
capacity
n
No de-rating required. All circuits rated for
full current load
n
Extra long pre-grounding contact engages
before any other contacts for greater safety.
Electrical
Voltage: 250V
Maximum Current:
10 Amp
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
Mechanical
Operating Temperature:
150
o
C
38330, 38336
Angled Bracket (AB)
Angle Bracket Tapped (ABT)
Less Angle Bracket (LAB)
Physical
Base Insulator: High-grade phenolic, black
Plug Contact: Brass
Plug Contact Plating: Tin
Socket Contact: Phosphor bronze
Socket Contact Plating: Tin
Pre-grounding Contact: Heavy-duty plated brass
SUGGESTED PANEL MOUNTING DIMENSIONS
CONTACT TAILS
Molex offers a wide selection of contact tails. Consult factory for
availablility and part numbers of other styles
Fig. D
Diameter
.156”
(3,96)
Reference Information
UL :
CSA:
File E34763
File 22156
.66”
(16,8)
38330-XX02
Diameter
.156”
(3,96)
.020”
(0,51)
Fig. E
.031”
(0,80)
Diameter
.156”
(3,96)
P Solder Eye (Standard)
.07” x .10”
(1,78 x 2,54)
.30”
(7,62)
.38”
(9,65)
P
7
Printed Circuit and
Wire Wrap, Short
.25”
(6,35)
.045” square
(1,14)
.97”
(24,6)
.078”
(1,98)
.44”
(11,1)
Diameter
.672”
(17,1)
38330-XX03-15
S
1
Quick Connect
.22”
(5,59)
Diameter
.156”
(3,96)
.06”
(1,59)
.44”
(11,1)
.110” x .020
(2,79 x 0,51)
P
1
Quick Connect
.39”
(9,91)
.110” x .020
(2,79 x 0,51)
Fig. F
Fig. G
Diameter
.156”
(3,96)
S Solder Eye (Standard)
.22”
(5,59)
1.015”
(25,8)
.07” x .10”
(1,78 x 2,54)
.25”
(6,35)
S
6
Printed Circuit
.10”
(2,54)
.03” x .04”
(0,76 x 1,02)
1.38”
(34,9)
38330-XX18-33
.06”
(1,59)
.032”
(0,81)
Diameter
.156”
(3,96)
1.375”
(34,9)
P
4
Wire Wrap, Long
.75” .63”
(19,1) (16,0)
.045” square
(1,14)
Diameter
.156”
(3,96)
Contact Orientation
The polarization arrangement numbers shown below are for sockets, as viewed from the wiring side. Plug numbering is the opposite. A heavy-duty polarizing/ground contact is in position 14 for Nos. 3324, 3327,
3330 and in position 17 for No. 3333. * Indicates location of pre-grounding contact. † Pregrounding contact is standard.
38330-XX02
38330-XX03
38330-XX04
38330-XX06
38336-8XXX
38330-XX08
38330-XX10
38330-XX12
38330-XX15 to 38330-XX21
38330-XX24 to 38330-XX30
38330-XX33
ORDERING INFORMATION AND DIMENSIONS
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
38330, 38336
Part #
in
3302*
3303
3304
3306
3306-8
3308
3310
3312
3315
3318
3321
3324
3327
3330
3333
0.66
1.00
0.75
1.00
1.00
1.25
1.56
1.25
1.63
1.94
2.25
2.56
2.88
3.19
3.50
T
mm
16,7
25,4
19,1
25,4
25,4
31,8
39,7
31,8
41,3
49,2
57,2
65,1
73,0
81,0
88,9
U
in
--
.44
.69
.69
.69
.69
.69
.94
1.00
1.00
1.00
1.00
1.00
1.00
1.00
V
mm
--
11,1
17,5
17,5
17,5
17,5
17,5
23,8
25,4
25,4
25,4
25,4
25,4
25,4
25,4
Part #
mm
32,1
27,0
33,3
33,3
33,3
33,3
33,3
39,7
42,9
42,9
42,9
42,9
42,9
42,9
42,9
3302*
3303
3304
3306
3306-8
3308
3310
3312
3315
3318
3321
3324
3327
3330
3333
Fig. #
in
D
E
F
E
E
F
F
F
F
G
G
G
G
G
G
.969
.750
1.000
1.000
1.000
1.000
1.000
1.250
1.375
1.250
.938
1.250
1.562
1.875
2.188
A
mm
24,6
19,1
25,4
25,4
25,4
25,4
25,4
31,8
34,9
31,8
23,8
31,8
39,7
47,6
55,6
B
in
--
1.016
.781
1.031
1.031
1.281
1.578
1.266
1.640
1.953
2.265
2.578
2.890
3.203
3.515
C
mm
--
25,8
19,8
26,2
26,2
32,5
40,1
32,2
41,7
49,6
57,5
65,5
73,4
81,4
89,3
in
1.27
1.06
1.31
1.31
1.31
1.31
1.31
1.56
1.69
1.69
1.69
1.69
1.69
1.69
1.69
in
--
.453
.719
.719
.719
.719
.719
.953
1.016
--
--
--
--
--
--
mm
--
11,5
18,3
18,3
18,3
18,3
18,3
24,2
25,8
--
--
--
--
--
--
PLUGS
Angle Bracket (-AB)
Order #
38330-0102
38330-0103
38330-0104
38330-0106
38336-8001
38330-0108
38330-0110
38330-0112
38330-0115
38330-0118
38330-0121
38330-0124
38330-0127
38330-0130
38330-0133
Engineering #
P-3302-AB
P-3303-AB
P-3304-AB
P-3306-AB
P-3306-8-AB
P-3308-AB
P-3310-AB
P-3312-AB
P-3315-AB
P-3318-AB
P-3321-AB
P-3324-AB
P-3327-AB
P-3330-AB
P-3333-AB
Angle Bracket Tapped (-ABT)
Order #
38330-1502
38330-1503
38330-1504
38330-1506
38336-8015
38330-1508
38330-1510
38330-1512
38330-1515
38330-1518
38330-1521
38330-1524
38330-1527
38330-1530
38330-1533
Engineering #
P-3302-ABT
P-3303-ABT
P-3304-ABT
P-3306-ABT
P-3306-8-ABT
P-3308-ABT
P-3310-ABT
P-3312-ABT
P-3315-ABT
P-3318-ABT
P-3321-ABT
P-3324-ABT
P-3327-ABT
P-3330-ABT
P-3333-ABT
Less Angle Bracket (-LAB)
Order #
38330-2202
38330-2203
38330-2204
38330-2206
38336-8022
38330-2208
38330-2210
38330-2212
38330-2215
38330-2218
38330-2221
38330-2224
38330-2227
38330-2230
38330-2233
Engineering #
P-3302-LAB
P-3303-LAB
P-3304-LAB
P-3306-LAB
P-3306-8-LAB
P-3308-LAB
P-3310-LAB
P-3312-LAB
P-3315-LAB
P-3318-LAB
P-3321-LAB
P-3324-LAB
P-3327-LAB
P-3330-LAB
P-3333-LAB
SOCKETS
Angle Bracket (-AB)
Order #
38330-0502
38330-0503
38330-0504
38330-0506
38336-8005
38330-0508
38330-0510
38330-0512
38330-0515
38330-0518
38330-0521
38330-0524
38330-0527
38330-0530
38330-0533
Engineering #
S-3302-AB
S-3303-AB
S-3304-AB
S-3306-AB
S-3306-8-AB
S-3308-AB
S-3310-AB
S-3312-AB
S-3315-AB
S-3318-AB
S-3321-AB
S-3324-AB
S-3327-AB
S-3330-AB
S-3333-AB
Angle Bracket Tapped (-ABT)
Order #
38330-1902
38330-1903
38330-1904
38330-1906
38336-8019
38330-1908
38330-1910
38330-1912
38330-1915
38330-1918
38330-1921
38330-1924
38330-1927
38330-1930
38330-1933
Engineering #
S-3302-ABT
S-3303-ABT
S-3304-ABT
S-3306-ABT
S-3306-8-ABT
S-3308-ABT
S-3310-ABT
S-3312-ABT
S-3315-ABT
S-3318-ABT
S-3321-ABT
S-3324-ABT
S-3327-ABT
S-3330-ABT
S-3333-ABT
Less Angle Bracket (-LAB)
Order #
38330-2602
38330-2603
38330-2604
38330-2606
38336-8026
38330-2608
38330-2610
38330-2612
38330-2615
38330-2618
38330-2621
38330-2624
38330-2627
38330-2630
38330-2633
Engineering #
S-3302-LAB
S-3303-LAB
S-3304-LAB
S-3306-LAB
S-3306-8-LAB
S-3308-LAB
S-3310-LAB
S-3312-LAB
S-3315-LAB
S-3318-LAB
S-3321-LAB
S-3324-LAB
S-3327-LAB
S-3330-LAB
S-3333-LAB
FEATURES AND SPECIFICATIONS
Features and Benefits
n
Sizes 15 to 33 circuits
n
Robust blade contacts resist damage
fromimproper mating
n
Large surface area of dual wipe female
contact produces maximum current
capacity
n
No de-rating required. All circuits rated
for full current load
n
Extra long pre-grounding contact
engages before any other contacts for
greater safety.
Electrical
Voltage: 250V
Maximum Current: 10 Amp
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
Mechanical
Operating Temperature:
150
o
C
38330
Shallow Bracket (SB)
Physical
Base Insulator:High-grade phenolic, black
Plug Contact: Brass
Plug Contact Plating: Tin
Socket Contact: Phosphor bronze
Socket Contact Plating: Tin
Pre-grounding Contact: Heavy-duty plated brass
SUGGESTED PANEL MOUNTING DIMENSIONS
CONTACT TAILS
Molex offers a wide selection of contact tails. Consult factory for
availablility and part numbers of other styles
Reference Information
UL :
CSA:
File E34763
File 22156
.032”
(0,81)
Fig. K
1.08”
(27.4)
P Solder Eye (Standard)
.07” x .10”
(1,78 x 2,54)
.30”
(7,62)
P
7
Printed Circuit and
Wire Wrap, Short
.25”
(6,35)
.38”
(9,65)
.045” square
(1,14)
1.38”
(34.9)
.44”
(11,1)
Diameter
.187”
(4,75)
S
1
Quick Connect
.22”
(5,59)
.110” x .020
(2,79 x 0,51)
P
1
Quick Connect
.39”
(9,91)
.110” x .020
(2,79 x 0,51)
S Solder Eye (Standard)
.22”
(5,59)
Diameter
.190”
(4.83)
.07” x .10”
(1,78 x 2,54)
.25”
(6,35)
S
6
Printed Circuit
.10”
(2,54)
.03” x .04”
(0,76 x 1,02)
P
4
Wire Wrap, Long
.75” .63”
(19,1) (16,0)
.045” square
(1,14)
Contact Orientation
The polarization arrangement numbers shown below are for sockets, as viewed from the wiring side. Plug numbering is the opposite. A heavy-duty polarizing/ground contact is in position 14 for Nos. 3324, 3327,
Recent trends show that color screens are rapidly becoming standard features of most new mobile phones, PDAs and digital cameras. Color screens, games , Internet browsing and text messaging require lo...
In the process of developing embedded applications, although good programming practices and appropriate coding standard detection software can reduce the number of errors in the code writing stage, it...
Fiber to the home (FTTH) has been a dream and technical direction that people have been pursuing for 20 years. Almost no one denies that FTTH will be the best way to access broadband in the future. Co...
Which board is better for getting started? Some boards are very expensive. I have learned the basics of microcontrollers in college. I would like to ask for help from an expert!...
I want to read the camera data. The camera has an FPD-LINK2 interface, which has only one pair of LVDS differential data lines (similar to UART). Because there is no synchronous clock, I checked some ...
What is "Car Electronic Fence"
Fleet managers can define a graphical area (regular or irregular) or divide it into administrative zones in Yamei Technology's vehicle backend management system ...[Details]
The structure of an LCD TV primarily consists of the LCD display module, power module, driver module (primarily including the main driver board and tuner board), and keypad module. LCD display modu...[Details]
1. Introduction
Electronic scales are gradually replacing traditional measuring tools like springs and balances in everyday life, such as electronic price computing scales and electronic weigh...[Details]
Recently, Tesla released the "Tesla Car Voice Assistant Terms of Use", announcing that the car voice assistant will be connected to the Doubao large model (Skylark large model) and DeepSeek Chat pr...[Details]
Smartphones have become essential digital devices, and the growing number of smartphone-centric applications is enriching people's lives. As users, they desire a better app experience and a wider r...[Details]
Spark plugs are an indispensable device for engines. As the saying goes, without spark plugs, the engine cannot work properly. The serious consequence is that when driving at high speeds, the engin...[Details]
Electric vehicles are powered by electricity, and charging is a device that supplements the vehicle's energy source. It is common to need to recharge the vehicle when driving. But can you charge th...[Details]
With the continuous development of the industrial automation industry, we are seeing an increasing number of intelligent devices using flexible, efficient, and precise robotic arms to p...[Details]
According to Nikkei, Japan has performed poorly in responding to China's power semiconductor challenges.
There are five major companies in Japan's power chip market: Mitsubishi Electric,...[Details]
Before understanding single-phase control transformers, let's briefly understand what a single-phase transformer is. A single-phase transformer uses a single-phase input. Compared to a three-phase ...[Details]
Electric vehicles will revolutionize transportation, changing fuel consumption, carbon emissions, costs, maintenance, and driving habits. Currently, a major selling point for electric vehicles is t...[Details]
The second-generation Snapdragon W5+ and second-generation Snapdragon W5 platforms support users sending and receiving messages via satellite when there is no cellular and Wi-Fi coverage.
...[Details]
introduction
With the development of society, people's requirements for the quality of refrigerated and frozen foods are constantly improving. The changes in food appearance and nutritional co...[Details]
Cadence and NVIDIA Collaborate to Revolutionize Power Analysis Technology, Accelerating Development of Billion-Gate AI Designs
Cadence's new Palladium Dynamic Power Analysis applicat...[Details]
Renesas Electronics introduces a new USB-C power solution with an innovative three-level topology.
Improve performance while reducing system size
New solution combines excel...[Details]