pHE841
• Emi suppressor, class x1, metallized polypropylene
• 0.01 – 2.2 µf, 330 vac, +100°c
L
RoHS
Compliant
B
tYpiCaL appLiCations
For worldwide use as electromagnetic
interference suppressor in all X1 and
across-the-line applications.
Not for use in series with the mains.
See www.kemet.com for more information.
ConstRuCtion
Metallized polypropylene winding,
encapsulated in self-extinguishing material
meeting the requirements of UL 94 V–0.
0.5
p
∅
d
l
H
tECHniCaL data
rated voltage
capacitance range
capacitance tolerance
temperature range
climatic category
approvals
dissipation factor tanδ
330 VAC 50/60 Hz
0.01 – 2.2 µF
± 20% standard, ± 10% option
–40 to +100°C
40/100/56/B
ENEC, UL, cUL
Maximum values at +23°C
C
≤
0.1 µF 0.1µF < C
≤
1 µF
1 kHz
0.1%
0.1%
10 kHz
0.2%
0.4%
100 kHz
0.6%
–
C > 1 µF
0.1%
0.8%
–
p
b
d
0.6
0.8
0.8
0.8
1.0
std l
17
17
6
6
6
max l
30
30
30
30
30
b
±0.4
±0.4
±0.4
±0.4
±0.7
10.0 ± 0.4
15.0 ± 0.4
22.5 ± 0.4
27.5 ± 0.4
37.5 ± 0.5
Tolerance in lead length
< 30 mm
+0
mm
–1
30 mm
+5
–0
mm
test voltage between
terminals
The 100% screening factory test is carried out at 3000
VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Tabulated self-resonance frequencies f
0
refer to 5 mm lead length.
C
≤
0.33 µF:
≥
30 000 MΩ
C > 0.33 µF:
≥
10 000 s
Recommended voltage:
≤
1000 VDC
resonance frequency
insulation resistance
in dc applications
EnViRonmEntaL tEst data
Endurance
EN/IEC 60384-14:2005
1.25 x U
R
VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
3 directions at 2 hours each,
10–55 Hz at 0.75 mm or 98 m/s
2
1000 bumps at
390 m/s
2
Upper and lower rated
temperature 5 cycles
No visible damage
No open or short circuit
No visible damage
No open or short circuit
No visible damage
vibration
Bump
IEC 60068–2–6
Test Fc
IEC 60068–2–29
Test Eb
change of temperature
IEC 60068–2–14
Test Na
active flammability
Passive flammability
humidity
EN/IEC 60384-14:2005
EN/IEC 60384-14:2005
Enclosure material of
UL94V–0 flammability class
+40°C and
90 – 95% R.H.
56 days
IEC 60068-2-3
Test Ca
PhE841
aRtiCLE taBLE
capaci- Box max dimensions
max
tance code in mm
f
o
du/dt article code
µf
B
h
l
mhz v/µs
capaci- Box max dimensions
max
tance code in mm
f
o
du/dt article code
µf
B
h
l
mhz v/µs
lEad sPacinG 10 mm
0.010
0.012
0.015
0.018
0.022
A02
A03
A03
A04
A04
4.5
5.0
5.0
6.0
6.0
10.5
11.0
11.0
12.0
12.0
13.0
13.0
13.0
13.0
13.0
11
10
9.4
8.7
8.1
100
100
100
100
100
PHE841EA5100MR17
PHE841EA5120MR17
PHE841EA5150MR17
PHE841EA5180MR17
PHE841EA5220MR17
0.22
0.27
0.33
0.39
0.47
0.56
0.68
0.82
1.0
F11
F11
F12
F03
F03
F13
F14
F15
F16
10.5
10.5
11.5
13.5
13.5
14.5
17.5
19.0
21.0
lEad sPacinG 27.5 mm
20.5
20.5
22.5
23.0
23.0
24.5
28.0
29.0
30.0
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
2.0
1.8
1.6
1.4
1.3
1.2
1.1
1.0
1.0
100
100
100
100
100
100
100
100
100
PHE841EF6220MR06L2
PHE841EF6270MR06L2
PHE841EF6330MR06L2
PHE841EF6390MR06L2
PHE841EF6470MR06L2
PHE841EF6560MR06L2
PHE841EF6680MR06L2
PHE841EF6820MR06L2
PHE841EF7100MR06L2
lEad sPacinG 15 mm
0.010
0.012
0.015
0.018
0.022
0.027
0.033
0.039
0.047
0.056
0.068
0.082
0.10
B04
B04
B04
B04
B05
B15
B10
B06
B06
B12
B11
B14
B14
5.5
5.5
5.5
5.5
5.5
6.0
6.5
7.5
7.5
8.0
8.5
9.5
9.5
10.5
10.5
10.5
10.5
12.5
12.0
12.5
14.5
14.5
15.0
16.0
17.5
17.5
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
10
9.4
8.7
7.9
7.2
6.5
5.9
5.4
5.0
4.6
4.2
3.8
3.7
100
100
100
100
100
100
100
100
100
100
100
100
100
PHE841EB5100MR17
PHE841EB5120MR17
PHE841EB5150MR17
PHE841EB5180MR17
PHE841EB5220MR17
PHE841EB5270MR17
PHE841EB5330MR17
PHE841EB5390MR17
PHE841EB5470MR17
PHE841EB5560MR17
PHE841EB5680MR17
PHE841EB5820MR17
PHE841EB6100MR17
lEad sPacinG 37.5 mm
0.68
0.82
1.0
1.2
1.5
1.8
2.2
*
R05
R04
R04
R02
R03
R06
R06
13.0
15.0
15.0
16.5
19.0
21.0
21.0
24.0
26.0
26.0
32.0
36.0
38.0
38.0
41.0
41.0
41.0
41.0
41.0
41.0
41.0
1.1
1.0
0.92
0.84
0.74
0.67
0.60
100
100
100
100
100
100
100
PHE841ER6680MR06L2
PHE841ER6720MR06L2
PHE841ER7100MR06L2
PHE841ER7120MR06L2
PHE841ER7150MR06L2
PHE841ER7180MR06L2
PHE841ER7220MR06L2
Only ±20 %
lEad sPacinG 22.5 mm
0.068
0.082
0.10
0.12
0.15
0.18
0.22
0.27
0.33
0.39
0.47
D13
D17
D17
D14
D15
D18
D18
D16
D16
D19
D19
6.5
7.0
7.0
8.0
9.0
10.5
10.5
11.0
11.0
15.5
15.5
14.5
16.5
16.5
16.0
18.5
19.0
19.0
21.5
21.5
24.5
24.5
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
2.9
2.8
2.7
2.6
2.5
2.3
2.2
2.0
1.9
1.6
1.5
100
100
100
100
100
100
100
100
100
100
100
PHE841ED5680MR06L2
PHE841ED5820MR06L2
PHE841ED6100MR06L2
PHE841ED6120MR06L2
PHE841ED6150MR06L2
PHE841ED6180MR06L2
PHE841ED6220MR06L2
PHE841ED6270MR06L2
PHE841EY6330MR06L2 *
PHE841ED6390MR06L2
PHE841ED6470MR06L2
appRoVaLs
certification Body
ENEC
UL
specification
EN/IEC 60384-14:2005
maRKing
•
•
•
•
•
•
•
•
•
•
RIFA
RIFA article code
Rated capacitance
Capacitance tolerance code
Rated voltage
X1
Approval marks
Manufacturing date code
IEC climatic category
Passive flammability class
UL 60384-14
CAN/CSA-E60384-14:09
oRdERing inFoRmation
The article code for the standard part is given in the article table.
Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute –
and we specifically disclaim – any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who
have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.