Display for Digital Signals
Types FK3C3, FK4C3
•
•
•
•
•
Du line
®
Fieldbus
Installationbus
8-, 16- or 32-channel status indicator
8-, 16- or 32-dot LED display
NPN transistor output for loss of Dupline
®
carrier
Horizontal or vertical panel mounting, DIN 43700
AC/DC power supply
Product Description
Dupline
®
display for panel
mounting. Status indication
of 8, 16 or 32 channels in 8-,
16- or 32-segment single-
point LED representation.
Display function normal or
inverted for fast locating of
deviations from normal
operation, e.g. missing start-
up conditions, open doors
and windows, machine fault
annunciation etc.
Ordering Key
Type: Dupline
®
Display type
Housing
Type no.
Supply
FK3C 3508 024
Type Selection
Supply
Ordering no.
8 channels
8-dot LED
FK3C 3508 024
FK3C 3508 120
FK3C 3508 220
*
FMK A to FMK P
Ordering no
16 channels
16-dot LED
FK3C 3616 024
FK3C 3616 120
FK3C 3616 220
*
FMK A-B to O-P
Ordering no.
32 channels
32-dot LED
FK4C 3732 024
FK4C 3732 120
FK4C 3732 220
*
FMK A-D to M-P
24 VAC
120 VAC
220 VAC
12 VDC
Code module
*
All AC-types may be supplied with 12 VDC at pins 2 & 3
Display/Output Specifications
F.3C 3508 ...
( 8 channels)
Display
Display format
Display range
Display type
Size of dots
Display colour
Display test
Transmission protocol
Channel status
8 dots
LED
5 x 5 mm
Red
None
Binary
F.3C 3616 ...
(16 channels)
Channel status
16 dots
LED
6 x 3 mm
Red
None
Binary
F.4C 3732 ...
(32 channels)
Channel status
32 dots
LED
5 x 2 mm
Red
None
Binary
Specifications are subject to change without notice (28.09.99)
Dupline
®
is a registered trademark. A product of the CARLO GAVAZZI Group
1
FK3C3, FK4C3
Du line
®
Fieldbus
Installationbus
Display/Output Specifications (cont.)
F.3C 3508 ...
( 8 channels)
1 NPN transistor
4 to 35 VDC (or V
DD
in)
Yes
≤
100 mA
None
None
≤
100 µA
≤
1.5 V
≤
3m
None
2.8 mm faston
2.8 mm faston
< 2 pulse trains
F.3C 3616 ...
(16 channels)
1 NPN transistor
4 to 35 VDC (or V
DD
in)
Yes
≤
100 mA
None
None
≤
100 µA
≤
1.5 V
≤
3m
None
2.8 mm faston
2.8 mm faston
< 2 pulse trains
F.4C 3732 ...
(32 channels)
1 NPN transistor
4 to 35 VDC (or V
DD
in)
Yes
≤
100 mA
None
None
≤
100 µA
≤
1.5 V
≤
3m
None
2.8 mm faston
2.8 mm faston
< 2 pulse trains
Output
Output voltage range V
BB
Reverse-polarity protection
Current per output
Short-circuit protection
Built-in protective diodes
Off-state leakage current
Output voltage drop
Cable length
Dielectric voltage
Output - Dupline
®
Output connection
Dupline
®
connection
Response time
Supply Specifications
Power supply AC types
Operational voltage
through pins A1 & A2 220
120
024
Frequency
Voltage interruption
Rated operational power
Rated impulse withstand
voltage
220
120
024
Dielectric voltage
Supply - Dupline
®
Supply - Output
Alternative DC supply
Operational voltage (V
DD
in)
through pins 2 & 3
FK...
Reverse polarity protection
Rated operational current
FK3C 3508
FK3C 3616
FK4C 3732
Inrush current
Transient protection voltage
Dielectric voltage
Supply - Dupline
®
Supply - Output
Supply connection
Overvoltage cat. III (IEC 60664)
230 VAC +6%, -15% (IEC 60038)
120 VAC ± 10% (IEC60038)
24 VAC ± 10%
45 to 65 Hz
≤
40 ms
Typ. 6 VA
4 kV
2.5 kV
800 V
≥
2 kVAC (rms)
≥
2 kVAC (rms)
Overvoltage cat. III (IEC 60664)
12 VDC ± 10%
(ripple included)
Yes
≤
125 mA
≤
250 mA
≤
500 mA
≤
1A
800 V
None
None
2.8 mm faston
General Specifications
Output-off delay
upon loss of Dupline
®
carrier
Power ON delay
Indication for
Loss of Dupline
®
carrier
Environment
Degree of protection
Pollution degree
Operating temperature
Storage temperature
Humidity
(non-condensing)
Mechanical resistance
Shock
Vibration
Dimensions
Material
(see "Technical Information")
Weight
F.3C 3508
F.3C 3616
F.4C 3732
Approvals
≤
3 s, (LCD irregular
display indication)
Undefined
≤
1 s
LED, red
IP 40
3 (IEC 60664)
0° to +50°C (+32° to +122°F)
-20° to +60°C (-4° to +140°F)
20 to 80%
15 G (11 ms)
2 G (6 to 55 Hz)
F.3C: 96 x 48 - Housing
F.4C: 144 x 48 - Housing
300 g
300 g
400 g
CSA, UL
2
Specifications are subject to change without notice (28.09.99)
Dupline
®
is a registered trademark. A product of the CARLO GAVAZZI Group
FK3C3, FK4C3
Du line
®
Fieldbus
Installationbus
Mode of Operation
8-, 16- or 32-channel status
indicator with LED dot dis-
play.
The displays are used to
monitor 1, 2 or 4 Dupline
®
channel groups.
The output dots turn on when
the respective channels of
the selected channel groups
are activated by transmitters.
Each dot represents the sta-
tus of one Dupline
®
chan-
nel. The lowest figure on the
front plate indicates the low-
est channel of the first chan-
nel group and the highest
figure indicates the highest
channel of the last channel
group selected by the code
module.
In case of Dupline
®
carrier
loss the fault LED and the
output (pins 2 & 5) turn on.
Reaction time typically 1 s.
Note:
• Upon loss of Dupline
®
carrier the channel dots of
an LED display turn off.
• If DC-supplied displays are
used the length of the sup-
ply bus must not exceed
3 m in order to avoid distur-
bances unbalancing the
Dupline
®
.
Operation Diagram
Power supply
Dupline
®
carrier
Transmission on lowest chan.
Dot no. 1
Transmission on highest channel
Highest dot no.
Fault LED/output
Wiring Diagrams
AC supply
DC supply
AC supply
Output
load
V
BB
V
DD
in
Output
load
S: signal wire
S: signal wire
Additional Information
Scope of supply:
1 x Display
F..C...
1 x Front plate for horizontal mounting
1 x Front plate for vertical mounting
Accessories
For further information refer to "Accessories".
Specifications are subject to change without notice (28.09.99)
Dupline
®
is a registered trademark. A product of the CARLO GAVAZZI Group
3