EEWORLDEEWORLDEEWORLD

Part Number

Search

0031.1751

Description
Fuse Holder FEU FUSEHOLDER 5X20 IP 40
CategoryCircuit protection   
File Size310KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric View All

0031.1751 Overview

Fuse Holder FEU FUSEHOLDER 5X20 IP 40

0031.1751 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerSCHURTER
Product CategoryFuse Holder
Factory Pack Quantity100
Unit Weight0.292774 oz
Fuseholders
https://www.schurter.com /PG02
FEU
Shock-Safe Fuseholder, 5 x 20 / 6.3 x 32 mm, Slotted Cap
Socket with Slotted Cap
Caps must be ordered separately (see
accessories)
Socket with Slotted Cap
Socket with Fingergrip Cap
250 VAC · 4 W / 10 A (VDE) · 600 VAC/DC · 20 A (UL/CSA)
Description
See below:
Approvals and Compliances
Weblinks
pdf datasheet, html-datasheet, General Product Information, Packaging
details, Distributor-Stock-Check, Accessories, Detailed request for
product, Microsite
- Quick-conntect or solder terminals
Technical Data
PC2
5 x 20 or 6.3 x 32 mm
Panel Mount, Front Side
Fixing Nut
Solder or Quick-Connect 4.8 x 0.5 mm
250 VAC , 600 VAC/DC
10 A (VDE), 20 A (UL/CSA)
4 W / 10 A @ Ta 23 °C
Admissible power acceptance at higher
ambient temperature see derating cur-
ves
Degree of Protection
IP 40
Protection Class
Suitable for appliances with protection
class I acc. to IEC 61140
Admissible Ambient Air Temp. -40 °C to 85 °C
Climatic Category
40/085/21 acc. to IEC 60068-1
Material: Socket
Thermoplastic, black, UL 94V-0
Material: Terminals
Tin-Plated Copper Alloy
Unit Weight
5.5 g / 3.22 g
Storage Conditions
0 °C to 60 °C, max. 70% r.h.
Product Marking
, Type, Rated Voltage, Rated current,
Approvals
Shock-Safe Category
Fuse-Link
Mounting
Attachment
Terminal
Rated Voltage
Rated current
Rated Power Acceptance IEC
Soldering Methods
Solderability
Resistance to Soldering Heat
Contact Resistance
Dielectric Strength
Iron
Soldering Profile
350 °C / 2 - 3 sec acc. to IEC 60068-2-
20, Test Ta, method 2
350 °C / 10 sec acc. to IEC 60068-2-20,
Test Tb, method 2
10 mΩ at 20 mV acc. to IEC 60127-6
> 3 kV
> 4 kV between L/N-PE
(50 Hz; 1 min)
> 4 kV between L-N
> 6 kV between Front Panel and L/N
> 10 MΩ between L-N
> 100 MΩ between Front Panel and L/N
(500 VDC; 1 min)
III acc. to IEC 60664-1
3 acc. to IEC 60664-1
max 1.2 Nm
max 7 mm
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category
Pollution Degree
Admissible Torque on Fixing
Nut
Panel Thickness
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: FEU
Approval Logo
Certificates
VDE Approvals
UL Approvals
Certification Body
VDE
UL
Description
VDE Certificate Number: 40045912
UL File Number: E39328
Fuses
1
How to package a program written on Wince 5.0? Written in C#?
There are two, one is the Program Files folder and the other is the Application folder. What do they mean? Can you tell me what they mean?...
gongjun51201314 Embedded System
Character driver problem, urgent help needed.
The following is a driver for 8255 that I wrote. It uses EP9315. The following is the driver code: #ifdef MODULE #define __NO_VERSION__ #include #include #endif #define __KERNEL__ #include #include #i...
ageless Embedded System
Cross-clock domain design issues
When designing, I encountered two clocks, CLK1 and CLK2. CLK1 is an external clock, and CLK2 is an internal clock. Now, for example, we don't know the relationship between the two clocks (that is, the...
eeleader FPGA/CPLD
Nanhua University Huang Zhiwei Series--Grounding Treatment of Digital-Analog Hybrid Systems
[i=s]This post was last edited by paulhyde on 2014-9-15 03:36[/i]What is the ground wire?During the training process, students often have a very tangled question when using ADC or DAC: How to deal wit...
小煜 Electronics Design Contest
Has anyone used TM4C123GH6PM to do asynchronous motor vector control?
Who can provide the code for TM4C123GH6PM asynchronous motor vector control? It's paid!...
wangll1037 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1935  2572  311  1728  1948  39  52  7  35  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号