Circuit Breakers 20A MCB GCHAR 277VAC UL508
CategoryCircuit protection    Circuit protection   
File Size90KB,2 Pages
ManufacturerAltech
Websitehttp://www.altechcorp.com/
Download Datasheet View All

3GR20 Online Shopping

Suppliers Part Number Price MOQ In stock  
3GR20 - - View Buy Now

3GR20 Overview

Circuit Breakers 20A MCB GCHAR 277VAC UL508

G-TRIP
CHARACTERISTICS
Application Examples:
ONE POLE
ONE POLE PLUS NEUTRAL
General industrial, including motors,
some transformers, solenoids, control
circuits, lighting and wiring. Meets the
US trip norms with relatively short
thermal trip delay and high magnetic
trip point.
Type Designation
2
(a)
G
(b)
N
(c)
U
(d)
60
(e)
Rated
Current
0.3A
0.5A
0.75A
0.8A
1.0A
1.6A
2.0A
2.5A
3.0A
3.5A
4.0A
5.0A
6.0A
8.0A
10A
12A
12.5A
13A
15A
16A
20A
25A
30A
32A
40A
50A
60A
63A
277VAC
1G
Type/
Cat. No.
1GU03
1GU05
NA
1GU08
1GU1
1GU1.6
1GU2
1GU2.5
1GU3
1GU3.5
1GU4
1GU5
1GU6
1GU8
1GU10
1GU12
1GU125
1GU13
1GU15
1GU16
1GU20
1GU25
1GU30
1GU32
1GU40
1GU50
1GU60
1GU63
Approvals
UL
UL
2GN
Type/
Cat. No.
2GNU03
2GNU05
NA
2GNU08
2GNU1
2GNU1.6
2GNU2
2GNU2.5
2GNU3
2GNU3.5
2GNU4
2GNU5
2GNU6
2GNU8
2GNU10
2GNU12
2GNU125
2GNU13
2GNU15
2GNU16
2GNU20
2GNU25
2GNU30
2GNU32
2GNU40
2GNU50
2GNU60
2GNU63
277VAC
0.3-60A (RC): 10kA with UL-listed
RK5 back-up fuse or MCCB
0.3-10A (RC): 10kA; 12-60A (RC): 5kA
no branch circuit protection required
0.3-63A (RC): 10kA
10000 ON/OFF operations
40°C (104°F)
5/0.3A - 32A = 1.3kg (2.9 lb.)
40A - 63A = 1.45kg (3.2 lb.)
Top: 18-3 AWG; Bottom: 18-2 AWG
20 lb.in.
Approvals
UL
UL
(a)
= Number of Poles
(b)
= Trip Characteristic
(c)
= Blank: without neutral pole
= N:
with neutral pole
(d)
= U:
UL/CSA version
= R:
ring tongue terminals,
UL/CSA version
= Blank: European version
(e)
= Rated Current
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
UL
Approvals:
UL508 Listed
Voltage Rating
Interrupting Capacity
(UL/CSA - Ratings)
Group Short Circuit
(UL/CSA - Ratings)
Interrupting Capacity (VDE - Ratings)
Mechanical Endurance
Calibration Temperature
Standard Pack and Weight
Terminal Size Acceptability
Terminal Torque
Basic Dimensions (Elevation View)
Not European standard rating.
Please refer to page 21 for specific
0.3-60A (RC): 10kA with UL-listed
RK5 back-up fuse or MCCB
0.3-10A (RC): 10kA; 12-60A (RC): 5kA
no branch circuit protection required
0.3-63A (RC): 10kA
10000 ON/OFF operations
40°C (104°F)
10/0.3A - 32A = 1.4kg (3.1 lb.)
40A - 63A = 1.6kg (3.5 lb.)
Top: 18-3 AWG; Bottom: 18-2 AWG
20 lb.in.
applications.
DC rating (Manufacturer’s self certification):
91.5 mm
(3.60 in.)
91.5 mm
(3.60 in.)
One pole 48VDC, two pole series 125VDC
*
16
AC Motor Starting, Across-the-line approval
pending
17.5 mm (0.69 in.)
35 mm (1.38 in.)
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
Urgent! Urgent! Urgent! I have a question about UDP communication
I want to use UDP to implement communication between tasks in a multi-tasking program. This should be done on the local machine. I don't know how to do it. Can I just set the IP to the same 127.0.0.1?...
yyuan918 Embedded System
Embedded processors face side-channel attacks
Hardware vulnerabilities can affect the security of computers, medical devices, and systems. Secure enclaves and trust roots are not enough.  Computer security researchers have disclosed two major pro...
火辣西米秀 Microcontroller MCU
Teach you to understand the computer C drive system
[font=Verdana][url=http://bbs.elecfans.com/dispbbs_73_1879.html][font=Verdana][color=black]Teach you to understand the computer C drive system[/color][/font][/url][color=black][u]Addins folder This is...
zhou369506992 Embedded System
It’s time to make a decision again. I’m confused and in pain. Who can help me?
I reviewed my experiences over the past few years, and I feel a little lost. This article does not seek to moan or complain. I may be confused by the situation, and I may really be trapped. I just hop...
huixue5479 Embedded System
Screen migration issues under EVC
There is no button, and keyboard events are used to achieve the migration of the screen. How do you do it? Please give me some details, preferably with code. Thanks in advance...
guoguzh Embedded System
stc microcontroller information
If you need any information, please contact me...
guolear MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 235  1667  531  886  928  5  34  11  18  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号