BK/GBB-6-R

Description
Cartridge Fuses CERAMIC VERY FAST ACTING
CategoryCircuit protection    Circuit protection   
File Size218KB,2 Pages
ManufacturerEaton
Environmental Compliance
Download Datasheet Parametric View All

BK/GBB-6-R Overview

Cartridge Fuses CERAMIC VERY FAST ACTING

BK/GBB-6-R Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerEaton
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
Other featuresRATED BREAKING CAPACITY AT 125 VDC: 10000 A
Fusing characteristicsVERY FAST
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
Manufacturer's serial numberGBB
Installation featuresINLINE/HOLDER
method of packingBOX
physical size6.35mm x 31.75mm
Rated breaking capacity200 A
Rated current6 A
Rated voltage (AC)250 V
Rated voltage (DC)125 V
GuidelineCSA; UL
surface mountNO
Terminal shapeEND CAP
Technical Data
2013
Effective
May
2017
Supersedes
July
2009
GBB
1⁄4" x 1 1⁄4" Very-fast acting ceramic tube fuses
Agency information
UL Recognized Card: 1-30A (JFHR2, E56412)
CSA Component Accepted Card: 1-30A
(Class 1422-30 File 53787)
Ordering
Specify packaging, product, and option code
Product features
Very fast-acting
Optional axial leads available
1⁄4" x 1 1⁄4" (6.3 x 32mm) physical size
Ceramic tube, nickel-plated brass endcap
construction
100pc-carton quantity weighs 1.0 lb (0.45 kg)
UL Recognized product meets standard 248-14
Rated Current
1 - 20A
25, 30A
Electrical Characteristics
% of Amp Rating
Opening Time
100%
None
150%
2 minutes maximum
250%
1 seconds maximum
400%
-
100%
None
150%
2 minutes maximum
250%
6 seconds maximum
400%
-
Part Number
GBB-1-R
GBB-1-1/4-R
GBB-2-R
GBB-3-R
GBB-4-R
GBB-5-R
GBB-6-R
GBB-7-R
GBB-8-R
GBB-9-R
GBB-10-R
GBB-12-R
GBB-15-R
GBB-20-R
GBB-25-R
GBB-30-R
Voltage
Rating
Vac
Vdc
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
250
125
AC Interrupting
Rating (amps)*
250Vac
125Vac
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
200
200
200
200
200
Speci cations
DC Interrupting
Rating (amps)*
125Vdc
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
200
200
200
Typical DC Cold
Resistance
(Ω)**
0.17750
0.17900
0.06620
0.04475
0.03175
0.02125
0.01800
0.01550
0.01360
0.01070
0.00934
0.00620
0.00472
0.00330
0.00252
0.00206
Typical
Voltage
Drop (V)‡
0.2096
0.2497
0.1687
0.1816
0.1778
0.1217
0.1324
0.1355
0.1144
0.1218
0.0877
0.0806
0.0735
0.0728
0.0610
0.0657
* Interrupting ratings: Interrupting ratings for 1-15A at 125Vdc was measured at 10,000A, 3.5 ms maximum, with time constant. Ratings 20-30A at 125Vdc were measured at 200A, 0.5
ms maximum, with time constant. Ratings 1-15A at 125Vac were measured at 10,000A, and 70% - 80% power factor. The interrupting ratings for 1-30A at 250Vac were measured at
90% - 100% power factor.
** DC Cold Resistance (Measured at <10% of rated current)
† Typical Melting I
2
t (I
2
t was measured at listed interrupting rating and rated voltage) Interrupting ratings were measured at 70% to 80% power factor on AC.
‡ Typical Voltage drop (Voltage drop was measured at 25°C±3°C ambient temperature at rated current)

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1395  2539  2128  1055  1787  29  52  43  22  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号