https://www.phoenixcontact.com/hq/products/1401325
Sensor/Actuator cable - SAC-5P-M12MR/ 0,2-PUR/M12FR SH - 1401325
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/Actuator cable, 5-position, PUR, shielded, Plug angled M12, A-coded, on Socket angled M12, A-
coded, Cable length: 0.2 m
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4046356549479
85444290
Made to Order (non-returnable)
1 STK
50 STK
Technical data
Dimensions
Length of cable
0.2 m
General
Number of positions
Coding
Insertion/withdrawal cycles
5
A - standard
≥ 100
Cable
Cable type
Cable type (abbreviation)
Cable abbreviation
UL AWM style
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Thickness, insulation
Wire colors
Overall twist
Shielding
Optical shield covering
PUR halogen-free black
PUR
LiF9YC11Y
20549
5x 0.34 mm² (Signal line)
22
42x 0.10 mm
1.27 mm ±0.02 mm (Signal line)
≥ 0.21 mm
Brown, white, blue, black, gray
5 wires around filler to the core
Tinned copper braided shield
85 %
11/13/2016 Page 1 / 2
https://www.phoenixcontact.com/hq/products/1401325
Sensor/Actuator cable - SAC-5P-M12MR/ 0,2-PUR/M12FR SH - 1401325
Technical data
Cable
External sheath, color
External cable diameter D
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Number of bending cycles
Bending radius
Traversing path
Traversing rate
Acceleration
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage Core/Core
Special properties
Flame resistance
Halogen-free
Other resistance
Ambient temperature (operation)
black-gray RAL 7021
5.9 mm ±0.2 mm
29.5 mm
59 mm (up to +60°C)
4000000
59 mm
10 m
3 m/s
10 m/s²
48 kg/km
PUR
PP
Bare Cu litz wires
70 GΩ*km (at 20 °C)
max. 57 Ω/km (at 20 °C)
300 V (at 20 °C)
3000 V (at 20 °C)
Flexible cable conduit capable
in acc. with UL FT-2
in accordance with DIN VDE 0472 part 815
hydrolysis and microbe resistant
partly UV-resistant in accordance with DIN EN ISO 4892-2-A
-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (cable, flexible installation)
Drawings
Cable cross section
PUR halogen-free black [PUR]
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 2 / 2