SMDTC03470TB00MQ00

Description
Film Capacitors SMD-PET 0.47 F 63 VDC 7.2x6.1x5 SC2824
CategoryPassive components   
File Size172KB,7 Pages
ManufacturerWIMA
Websitehttps://www.wima.de/
Download Datasheet Parametric View All

SMDTC03470TB00MQ00 Online Shopping

Suppliers Part Number Price MOQ In stock  
SMDTC03470TB00MQ00 - - View Buy Now

SMDTC03470TB00MQ00 Overview

Film Capacitors SMD-PET 0.47 F 63 VDC 7.2x6.1x5 SC2824

SMDTC03470TB00MQ00 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerWIMA
Product CategoryFilm Capacitors
Capacitance0.47 uF
Voltage Rating DC63 VDC
Tolerance20 %
Length5 mm
Width7.2 mm
Height6.1 mm
Capacitance - nF470 nF
Capacitance - pF470000 pF
WIMA SMD-PET
Metallized Polyester (PET) SMD Film Capacitors with Box Encapsulation.
Capacitances from 0.01
mF
to 6.8
mF.
Rated Voltages from 63 VDC to 1000 VDC.
Size Codes from 1812 to 6054.
Special Features
˜
Size codes 1812, 2220, 2824,
4030, 5040 and 6054 with PET
and encapsulated
˜
Operating temperature up to 100° C
˜
Self-healing
˜
According to RoHS 2011/65/EU
D
Electrical Data
Capacitance range:
0.01
mF
to 6.8
mF
Rated voltages:
63 VDC, 100 VDC, 250 VDC, 400 VDC,
630 VDC, 1000 VDC
Capacitance tolerances:
±20%, ±10% (±5% available subject
to special enquiry)
Operating temperature range:
–55+ C to +100+ C (+125° C available
subject to special enquiry)
Climatic test category:
55/100/21 according to IEC
for size codes 1812 to 2824
55/100/56 according to IEC
for size codes 4030 to 6054
Insulation resistance
at +20+ C:
U
r
U
test
C
0.33
mF
3.75 x 10
3
1 x 10
4
63 VDC 50 V
100 VDC 100 V
250 VDC 100 V
Test voltage:
1.6 U
r
, 2 sec.
Voltage derating:
A voltage derating factor of 1.25 % per K
must be applied from +85) C for DC
voltages and from +75) C for AC
voltages
Reliability:
Operational life
300 000 hours
Failure rate
2 fit (0.5 x U
r
and 40+ C)
Typical Applications
For general DC-applications e.g.
˜
By-pass
˜
Blocking
˜
Coupling and decoupling
˜
Timing
Construction
Dielectric:
Polyethylene-terephthalate (PET) film
Capacitor electrodes:
Vacuum-deposited
Internal construction:
0.33
mF
< C
6.8
mF
1250 sec (M¸ x
mF)
3000 sec (M¸ x
mF)
Measuring time: 1 min.
Dissipation factors
at +20) C: tan
d
Plastic film
Vacuum-deposited
electrode
Metal contact layer
(schoopage)
Terminating plate
at f
1 kHz
10 kHz
100 kHz
C
0.1
mF
8 x 10
-3
15 x 10
-3
30 x 10
-3
0.1
mF
< C
1.0
mF
8 x 10
-3
15 x 10
-3
C > 1.0
mF
10 x 10
-3
Maximum pulse rise time:
for pulses equal to the rated voltage
Encapsulation:
Solvent-resistant, flame-retardant plastic
case, UL 94 V-0
Terminations:
Tinned plates.
Marking:
Box colour: Black.
Capacitance
m
F
0.01
0.033
0.1
0.33
1.0
3.3
...
...
...
...
...
...
0.022
0.068
0.22
0.68
2.2
6.8
Pulse rise time V/
m
sec
max. operation/test
100 VDC 250 VDC 400 VDC
35/350
20/200
10/100
6/60
4/40
3/30
40/400
40/400
12/120
9/90
7/70
35/350
21/210
14/140
10/100
63 VDC
30/300
20/200
10/100
8/80
3.5/35
3/30
630 VDC 1000 VDC
40/400
25/250
17/170
50/500
32/320
Dip Solder Test/Processing
Resistance to soldering heat:
Test Tb in accordance with DIN IEC
60068-2-58/DIN EN 60384-19.
Soldering bath temperature max. 260+ C.
Soldering duration max. 5 sec.
Change in capacitance
D
C/C
5 %.
Soldering process:
Re-flow soldering (see temperature/time
graphs page 13).
04.18
Packing
Available taped and reeled in blister pack.
Detailed taping information and graphs
at the end of the catalogue.
For further details and graphs please
refer to Technical Information.
17
What positions are there in the institute? From largest to smallest?
I want to set up a research institute. It is a corporate institution. I want to know what departments and positions there are. How are the positions of director, section chief, division chief, and dir...
fish001 Talking about work
Which domestic DC-DC and LDO should I choose?
Under the wave of localization, for industrial applications, which domestic DC-DC and LDO do you generally choose? What are the advantages and disadvantages?...
luckfrog Power technology
How to get accurate ADC sampling when PWM triggers ADC in motor control
In TI's official routine, ADC sampling sends out ADC conversion signal when the PWM1 time base counter counts equal to zero, triggering ADC to perform AD conversion. PWM time base count uses double-si...
swordman Microcontroller MCU
Complain about network cameras
[align=center].Nowadays, many people are at a loss as to how to buy network cameras. After all, they don't come into contact with such things in daily life, and when they really need them, they don't ...
wzq06633278902 Industrial Control Electronics
How to send specific data from PC to serial port and then control the operation of single chip?
I came up with an idea to use a temporary array temp to store the value in U0RXBUF, and then call the strcmp function for comparison. But the problem is that temp is an array of uncertain size, so cal...
zbnzbnzbnz Microcontroller MCU
How to Eliminate Competitive Risk Taking
module compare(out,a,b);input [7:0] a,b;output out;reg out;always @(a or b)begin if(ab)out=1; elseout=0;endendmoduleWhen performing gate-level simulation, glitches appear in the waveform, which is the...
超自然 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2850  904  1069  543  526  58  19  22  11  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号