EEWORLDEEWORLDEEWORLD

Part Number

Search

500X903U040BF2B

Description
Aluminum Electrolytic Capacitors - Screw Terminal 90KUF 40V -10+75%
CategoryPassive components   
File Size250KB,15 Pages
ManufacturerCornell Dubilier
Environmental Compliance
Download Datasheet Parametric View All

500X903U040BF2B Online Shopping

Suppliers Part Number Price MOQ In stock  
500X903U040BF2B - - View Buy Now

500X903U040BF2B Overview

Aluminum Electrolytic Capacitors - Screw Terminal 90KUF 40V -10+75%

500X903U040BF2B Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerCornell Dubilier
Product CategoryAluminum Electrolytic Capacitors - Screw Terminal
RoHSDetails
Capacitance90000 uF
Voltage Rating DC40 VDC
Tolerance- 10 %, + 75 %
Minimum Operating Temperature- 40 C
Maximum Operating Temperature+ 95 C
Diameter50.8 mm (2 in)
Length143 mm (5.625 in)
Lead Spacing22 mm (0.875 in)
Height0.762 mm
ProductAluminum Electrolytic Capacitors
Termination StyleScrew
Capacitance - uF90000 uF
Type 500C 95 °C Long Life, Screw Terminal, Aluminum
Long Life, High Capacitance Screw Terminal Type
Type 500C capacitors are designed for mainframe computers and
other long life UPS and power supply flter applications. They deliver
nearly as much capacitance as the Type DCMC capacitors, but with
two times the life expectancy. They are an excellent choice for high
ripple applications. The extended cathode foil of the 500C assures
cool operation with heat fow from the capacitor element to the can.
click here to see hardware and mounting options
Highlights
Specifcations
Temperature Range
Rated Voltage Range
Capacitance Range
Capacitance Tolerance
Leakage Current
Ripple Current Multipliers
- Long-life, High-Capacitance
- Better for Power-supply and UPS systems
- Thermal-Pak™ extended cathode construction
–40 °C to +95 °C
6.3 Vdc to 500 Vdc
100 µF to 2.6 F
–10% +75% ≤ 100 Vdc
–10% +50% ≥ 160 Vdc
≤3 √CV µA, 4 mA max, 5 minutes
Ambient Temperature
45 ºC
2.00
Frequency
1 3/8” & 1 3/4” Diameters
6.3 to 160 V
200 to 350 V
400 to 500 Vx
2” & 2 1/2” Diameters
6.3 to 160 V
200 to 350 V
400 to 500 V
3” & 3 1/2” Diameters
6.3 to 160 V
200 to 350 V
400 to 500 V
55 ºC
1.82
65 ºC
1.59
75 ºC
1.33
85 ºC
1.00
50 60 120 360 1
5 10 kHz
Hz Hz Hz Hz kHz kHz & up
0.91 0.93 1.00 1.06 1.08 1.10 1.10
0.76 0.81 1.00 1.24 1.36 1.43 1.44
0.76 0.81 1.00 1.24 1.37 1.44 1.45
0.93 0.95 1.00 1.04 1.06 1.06 1.07
0.78 0.83 1.00 1.20 1.29 1.34 1.35
0.77 0.82 1.00 1.22 1.33 1.39 1.40
0.95 0.97 1.00 1.03 1.04 1.04 1.04
0.84 0.88 1.00 1.12 1.17 1.20 1.20
0.79 0.84 1.00 1.18 1.26 1.31 1.32
Low Temperature Characteristics
Impedance ratio: Z
–20⁰C
∕ Z
+25⁰C
≤ 20 (6.3–10 Vdc)
≤ 8 (16–50 Vdc)
≤ 4 (63–100 Vdc)
≤ 3 (150–550 Vdc)
5000 h at full load at 85 °C
∆ Capacitance ±20%
ESR 200% of limit
DCL 100% of limit
500 h at 95 °C
Capacitance 100% of limit
ESR 100% of limit
DCL 100% of limit
10 to 55 Hz, 0.06” and 10 g max, 1.5 h each of 2 axes
RoHS Compliant
Endurance Life Test
Shelf Life Test
Vibration
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800
What is the relationship between the three less codes of OAD in CC254X?
OAD has three programming codes: BIM, IMAGE A, IMAGE B. Can someone explain: What is the relationship between these three codes and how to use them? If I compile and program according to IMAGE A, can ...
waferhit RF/Wirelessly
Shocked! One person made a company popular
I still remember the DIY work video of Mr. He shared on the forum not long ago. At the end of the video, there was an advertisement for the sponsor company. At that time, I thought this company was go...
他们逼我做卧底 RF/Wirelessly
【Arrow SoC】Use System Console to verify the hardware system
If you are using an Arrow SoC board and have burned the Linux kernel, do not insert the SD card. Otherwise, when testing the FPGA side light, the ARM will always control it, which may lead you to mist...
chenzhufly FPGA/CPLD
A strange question about the 430 interrupt.
In debug mode: If a breakpoint is set at the beginning of the interrupt program, the program can enter the interrupt and stay at the breakpoint. If no breakpoint is set, the program cannot enter the i...
movenight Microcontroller MCU
Basic knowledge of soft starter application
1. What is a soft starter? What is the difference between it and a frequency converter? A soft starter is a novel motor control device that integrates motor soft starting, soft stopping, light load en...
呱呱 Industrial Control Electronics
Automatic Test System of Shortwave Radio Station Based on Virtual Instrument Technology
Automatic Test System of Shortwave Radio Station Based on Virtual Instrument Technology Describes how to use virtual instrument technology to quickly and easily develop a shortwave radio automatic tes...
feifei Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2363  2462  853  2021  1787  48  50  18  41  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号