• Ideal for output applications of control equipments.
G
5
Q
■Ordering
Information
Terminal Shape
Market Code
Classification
Standard
SPDT (1c)
General purpose
PCB terminals
High-capacity
Home Appliance
SPST-NO (1a)
SPDT (1c)
SPST-NO (1a)
SPDT (1c)
Contact form
SPST-NO (1a)
Enclosure rating
Flux protection
Sealed
Flux protection
Sealed
Flux protection
Sealed
Flux protection
Sealed
Flux protection
Model
G5Q-1A
G5Q-1A4
G5Q-1
G5Q-14
G5Q-1A-EU
G5Q-1A4-EU
G5Q-1-EU
G5Q-14-EU
G5Q-1A-EU-HA
G5Q-1-EU-HA
Rated coil voltage
5VDC
9VDC
12VDC
24VDC
5VDC
12VDC
24VDC
12VDC
24VDC
Minimum packing unit
100 pcs/tray
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G5Q-1A DC5
Rated coil voltage
Note 2. Contact your OMRON sales representative for tube packing models.
■Ratings
●Coil
Contact form
Rated voltage
Rated current
(mA)
Coil resistance
(Ω)
Must operate
voltage
(V)
Must release
voltage
(V)
% of rated voltage
Max. voltage
(V)
Power
consumption
(mW)
5 VDC
125
40
9 VDC
405
22.2
SPST-NO (1a)
12 VDC
720
16.7
24 VDC
2880
8.3
75% max.
5% min.
5 VDC
63
80
9 VDC
202
44.4
SPDT (1c)
12 VDC
360
33.3
24 VDC
1440
16.7
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Approx. 200
190%
(at 23°C)
Approx. 400
1
G5Q
●Contacts
Load
Item
Contact Type
Contact material
Resistive load
SPST-NO (1a)
Standard
High-capacity
Standard
Single
Ag-Alloy (Cd free)
10 A at 125 VAC
3 A at 125 VAC
5 A at 250 VAC
3 A at 250 VAC
5 A at 30 VDC
10 A (NO)/3 A (NC)
277 VAC, 30 VDC
AC: 10 A (NO)/3 A (NC)
DC: 5 A (NO)/3 A (NC)
10 A at 250 VAC
3 A at 125 VAC
5 A at 250 VAC
3 A at 250 VAC
5 A at 30 VDC
10 A at 125 VAC (NO)
3 A at 125 VAC (NO)
5 A at 250 VAC (NO)
3 A at 250 VAC (NO)
5 A at 30 VDC (NO)
3 A at 125 VAC (NC)
3 A at 250 VAC (NC)
3 A at 30 VDC (NC)
10 A at 250 VAC (NO)
3 A at 125 VAC (NO)
5 A at 250 VAC (NO)
3 A at 250 VAC (NO)
5 A at 30 VDC (NO)
3 A at 125 VAC (NC)
3 A at 250 VAC (NC)
3 A at 30 VDC (NC)
SPDT (1c)
High-capacity
PCB Power Relay
Rated load
(resistive)
Rated carry current
Max. switching
voltage
Max. switching
current
■Characteristics
Item
Contact resistance *1
Operate time
Release time
Insulation resistance *2
Classification
100 mΩ max.
10 ms max.
5 ms max.
1,000 MΩ min.
4,000 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
8 kV (1.2 x 50
μs)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s
2
100 m/s
2
10,000,000 operations (18,000 operations per hour)
• NO
25,000 operations: 10 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 3 sec) <High-capacity type>
50,000 operations: 10 A at 125 VAC resistive load
(operation: ON for 1 sec, OFF for 3 sec)
200,000 operations: 3 A at 125 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
50,000 operations: 5 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 3 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 5 A at 30 VDC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
• NC
200,000 operations: 3 A at 125 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 3 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 3 A at 30 VDC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
10 mA at 5 VDC
-40°C to 105°C (with no icing or condensation)
-40°C to 85°C (with no icing or condensation) <High-capacity type>
5% to 85%
Approx. 6.5 g
Standard model
G
5
Q
Dielectric
strength
Between coil and contacts
Between contacts of the
same polarity
Impulse withstand voltage
(between coil and contacts)
Vibration
resistance
Shock
resistance
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Durability
Electrical
Failure rate (P level) (reference *3)
Ambient operating temperature
Ambient operating humidity
Weight
Note. Note. Values in the above table are the initial values at 23°C.
*1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
*2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.
*3. This value was measured at a switching frequency of 120 operations/min.
2
G5Q
■Engineering
Data
●Maximum
Switching Capacity
●Ambient
Temperature VS.
Maximum Coil Voltage
Standard
Maximum coil voltage (% of rated)
200
180
160
140
120
100
80
60
40
DC resistive load (NC)
1
1
20
100
1000
0
-40
-20
0
20 23 40
100
120
105
Ambient temperature (°C)
60
80
1,000
Z'
X
1,000
PCB Power Relay
●Shock
Malfunction
Y
1,000
Standard
Switching current (A)
100
Z
1,000
AC resistive load (NO)
10
DC resistive load (NO)
AC resistive load (NC)
NC
NO
Contact
300 Contact
300
1,000
X'
1,000
Y'
Unit: m/s
2
10
Switching voltgate (V)
High-capacity(-EU)
Switching current (A)
Maximum coil voltage (% of rated)
100
200
180
160
140
120
100
80
60
40
DC resistive load (NC)
1
1
20
100
1000
High-capacity(-EU)
Shock direction
Sample: G5Q-14 12 VDC
X
X'
Number of Relays: 5 pcs
Y
Test conditions: Shock is applied
Z
in ±X, ±Y, and ±Z directions three
Z'
times each with without
energizing the Relays to check
Y'
the number of malfunctions.
Requirement: None malfuction
100 m/s
2
AC resistive load (NO)
10
DC resistive load (NO)
AC resistive load (NC)
G
5
Q
10
0
-40
-20
0
20 23 40
Switching voltgate (V)
80
100
120
85
Ambient temperature (°C)
60
Note. The Maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
■Dimensions
G5Q-1A
G5Q-1A4
G5Q-1A-EU (-HA)
G5Q-1A4-EU
15.8MAX
(15.5)*
(Unit: mm)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
(1.18)
4-1
.
0.1
3±
20.3MAX
(20.0)*
10.3MAX
(10.0)*
(1.19)
dia
.
Terminal Arrangement/
Internal Connections
(Bottom View)
1
5
7.62±0.1
2
3
7.62±0.1
(No coil polarity)
0.4
3.4
0.4 x 0.4
0.27
MAX
10.16
7.62
1
7.62
* Average value
10.16±0.1
G5Q-1
G5Q-14
G5Q-1-EU (-HA)
G5Q-14-EU
15.8MAX
(15.5)*
20.3MAX
(20.0)*
10.3MAX
(10.0)*
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
(1.18)
5-1
.
0.1
3±
dia
.
Terminal Arrangement/
Internal Connections
(Bottom View)
(1.19)
7.62±0.1
1
5
2.54±0.1
5.08±0.1
2
4
3
0.4
3.4
0.4 x 0.4
0.27
MAX
10.16
5.08
2.54
1
7.62
* Average value
10.16±0.1
(No coil polarity)
3
G5Q
■Approved
Standards
UL Recognized:
CSA Certified:
Model
PCB Power Relay
(File No. E41515)
(File No. LR31928)
Coil ratings
Contact ratings
10 A 250 VAC N.O. only (Resistive) 40°C
Number of test
operations
6,000
100,000
6,000
Contact form
G5Q-1
G5Q-1-EU
G5Q-1A
G5Q-1A-EU
10 A 30 VDC N.O. only (Resistive) 40°C
SPST-NO (1a)
SPDT (1c)
5 to 48 VDC
4 A 120 VAC N.O. only (Resistive) 40°C
3 A 250 VAC N.C. only (Resistive) 40°C
3 A 30 VDC N.C. only (Resistive) 40°C
EN/IEC, VDE
Model
G5Q-1
G5Q-1A
(Certified/No.40009467)
Contact form
Coil ratings
Contact ratings
10 A making and 0 A breaking, 250 VAC (cosφ=1) 105°C
5 A marking and 3 A breaking, 30 VDC (0 ms) 105°C
SPST-NO (1a)
SPDT (1c)
5 A 250 VAC (cosφ=1) (N.O.) 105°C
5 to 48 VDC
10 A 250 VAC (cosφ=1) (N.O.) 65°C
5 A 30 VDC (0 ms) (N.O.) 65°C
3 A 30 VDC (0 ms) (N.C.) 65°C
4 A 250 VAC (cosφ=1) (N.O.) 85°C
Number of test
operations
10,000
75,000
10,000
100,000
G5Q-1-EU (-HA)
G5Q-1A-EU (-HA)
G
5
Q
Creepage distance
Clearance distance
Insulation material group
Type of insulation coil-contact circuit
open contact circuit
Rated Insulation voltage
Pollution degree
Rated voltage system
Over voltage category
Category of protection according to IEC 61810-1
Glow wire according to IEC 60335-1
Tracking Index of relay base
Flammability class according to UL94
Coil Insulation system
6.4 mm min.
5.5 mm min.
IIIa
Basic (Rated voltage 400 V) / Reinforced (Rated voltage 250 V)
Micro disconnection
250 V
2
250 V / 400 V (EU flux type only)
III
RT II (Flux protection) / RT III (Sealed)
<HA Models only>
GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)
PTI 250 V min. (housing parts)
V-0
F Class (UL 1446)
■Precautions
●Please
refer to “PCB Relays Common Precautions” for correct use.
•
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
•
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. J155-E1-11
0118(0207)(O)
4
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information: