F601KE102J400L

Description
Film Capacitors 1000PF 400V
CategoryPassive components   
File Size355KB,13 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

F601KE102J400L Online Shopping

Suppliers Part Number Price MOQ In stock  
F601KE102J400L - - View Buy Now

F601KE102J400L Overview

Film Capacitors 1000PF 400V

F601KE102J400L Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerKEMET
Product CategoryFilm Capacitors
Voltage Rating AC200 VAC
Tolerance5 %
Minimum Operating Temperature- 55 C
Maximum Operating Temperature+ 100 C
MMK
• Metallized polyester
• According to CECC 30401-042, IEC 60384-2, DIN 44122
L
RoHS
Compliant
B
typical applications
Bypassing, signal coupling. General
purpose for highest reliability.
construction
Metallized polyester film capacitor. Radial
leads of tinned wire are electrically welded
to the contact metal layer on the ends of
the capacitor winding. Encapsulation in
self-extinguishing material meeting the
requirements of UL 94V-0.
H
0.5
p
d
b
l
technical data
Rated voltage U
R
, VDC
Rated voltage U
R
, VAC
Capacitance, µF
Capacitance tolerance
Category temperature range
Voltage derating
Rated temperature
Climatic category
Test voltage
50
30
63
40
100
63
250
160
400
200
630
220
1000
250
p
p
7.5 ± 0.4
5.0 ± 0.4
10.0 ± 0.4
7.5 ± 0.4
15.0 ± 0.4
10.0 ± 0.4
15.0 ± 0.4
22.5 ± 0.4
22.5 ± 0.4
27.5 ± 0.4
27.5 ± 0.4
37.5 ± 0.5
37.5 ± 0.5
d
d
std l max l
std I max I
4
+1
+1
4
6
-1
+1
4
6
-1
+1
4
4
6
-1
+1
4
+1
6
-1
4
+1
6
-1
+1
4
b
b
0.001 0.001 0.001 0.001 0.001 0.001 0.001
–10.0 –82
–82
–39
–18
–6.8 –4.7
±20%, ±10% standard, ±5%.
–55 ... +100°C
Above +85°C DC and AC voltage derating is 1.25%/°C.
+85°C
IEC 60068-1, 55/100/56
DIN 40040, FME
–55 ... +100°C (+125°C)
Average relative humidity ≤ 75 %
RH = 95% for 30 days per year.
RH = 85% for further days limited by average value per
year, occasional slight condensation permitted.
1.6 x U
R
VDC for 2s
Max. 2% after a 2 year storage period at a temperature
of +10 ... +40°C and a relative humidity of 40...60%.
Operational life > 200 000 h.
Failure rate < 3 FIT, T = +40°C, U = 0.5 x U
R
.
Failure criteria according to DIN 44122.
0.6
0.5
0.6
0.6
0.8
0.6
0.8
0.8
0.8
0.8
0.8
1.0
1.0
20
20
± 0.4
± 0.4
30
20
± 0.4
± 0.4
30
± 0.4
30 ± 0.4
30
± 0.4
± 0.4
30
30
± 0.4
± 0.4
30
30 ± 0.4
30
± 0.7
30 ± 0.7
Z (Ω)
10
1.0
0.0
0.1
01
0.0
1
0.1
0.01
1
0.1
1.0
10
100 MHz
Capacitance drift
Reliability
Resonance frequencies
MMK 5
Z (Ω)
10
1.0
Maximum pulse
steepness:
Temperature coefficient
Self inductance
dU/dt according to article table. For peak to peak
voltages lower than rated voltage (U
pp
< U
R
), the
specified dU/dt can be multiplied by the factor U
R
/U
pp
.
+400 (±200) ppm/°C at 1 kHz
Approximately 6 nH/cm for the total length of capacitor
winding and the leads.
0.0
0.1
1
0.0
01
0.1
1.0
0.01
10
22
0.1
1.0
10
100 MHz
environMental test data
Damp heat test
Endurance test
Test conditions:
Test criteria:
Test conditions:
Test criteria:
T = +40°C, RH = 93%, t = 56 days.
∆ C/C ≤ ±5%,
∆ tanδ ≤ 0.005 (1kHz),
IR after test 0.5 x IR min.
T = +100°C, U = 1.25 x (0.8 x U
R
),
t = 2000 h.
∆ C/C ≤ ±5%,
∆ tanδ ≤ 0.005 (1kHz)
∆ tanδ ≤ 0.010 (100kHz)
IR after test 0.5 x IR min.
Resonance frequencies
MMK7.5 ... 37.5
Design of Series DC Stabilized Power Supply
1. Design task: Design a series voltage regulator using discrete components. 2. Design requirements: (1) Adjustable output voltage: U. =6~12V. (2) Output rated current: I =500mA. (3) Voltage regulatio...
李成楠 Power technology
29 electronic engineers stepped on the landmine! See if you are one of them?
Don’t think that programmers who are always fixing bugs are the ones who love to make mistakes. Electronic engineers are no exception! The key is that many times, engineers don’t think they are making...
btty038 RF/Wirelessly
my country's semiconductor equipment sales and output will increase significantly
Starting early and covering all categories can be said to be a summary of the development history of China's semiconductor equipment industry. However, at present, compared with the advanced level of ...
fighting Energy Infrastructure?
Developed SATA interface
share:-)...
yangz03 FPGA/CPLD
Help: I installed DSP Builder 7.2, and there is no device drop-down menu in scan jtag. What's wrong?
I installed DSP Builder 7.2, and there is no device drop-down menu in Scan JTAG. What's going on? My graduation project involves carrier tracking loop design, various filters, registers, and generator...
blackboard DSP and ARM Processors
Ask: Use VHDL to implement the continuous addition and subtraction function of the calculator
I am working on my final project now. I have implemented single addition and subtraction operations, but cannot implement continuous addition. Please give me a good idea! There is a small problem that...
zisepaopao FPGA/CPLD

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2770  2107  2346  1523  2381  56  43  48  31  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号