EEWORLDEEWORLDEEWORLD

Part Number

Search

F601BD274M100K

Description
Film Capacitors
CategoryPassive components   
File Size355KB,13 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Download Datasheet Parametric View All

F601BD274M100K Online Shopping

Suppliers Part Number Price MOQ In stock  
F601BD274M100K - - View Buy Now

F601BD274M100K Overview

Film Capacitors

F601BD274M100K Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerKEMET
Product CategoryFilm Capacitors
MMK
• Metallized polyester
• According to CECC 30401-042, IEC 60384-2, DIN 44122
L
RoHS
Compliant
B
typical applications
Bypassing, signal coupling. General
purpose for highest reliability.
construction
Metallized polyester film capacitor. Radial
leads of tinned wire are electrically welded
to the contact metal layer on the ends of
the capacitor winding. Encapsulation in
self-extinguishing material meeting the
requirements of UL 94V-0.
H
0.5
p
d
b
l
technical data
Rated voltage U
R
, VDC
Rated voltage U
R
, VAC
Capacitance, µF
Capacitance tolerance
Category temperature range
Voltage derating
Rated temperature
Climatic category
Test voltage
50
30
63
40
100
63
250
160
400
200
630
220
1000
250
p
p
7.5 ± 0.4
5.0 ± 0.4
10.0 ± 0.4
7.5 ± 0.4
15.0 ± 0.4
10.0 ± 0.4
15.0 ± 0.4
22.5 ± 0.4
22.5 ± 0.4
27.5 ± 0.4
27.5 ± 0.4
37.5 ± 0.5
37.5 ± 0.5
d
d
std l max l
std I max I
4
+1
+1
4
6
-1
+1
4
6
-1
+1
4
4
6
-1
+1
4
+1
6
-1
4
+1
6
-1
+1
4
b
b
0.001 0.001 0.001 0.001 0.001 0.001 0.001
–10.0 –82
–82
–39
–18
–6.8 –4.7
±20%, ±10% standard, ±5%.
–55 ... +100°C
Above +85°C DC and AC voltage derating is 1.25%/°C.
+85°C
IEC 60068-1, 55/100/56
DIN 40040, FME
–55 ... +100°C (+125°C)
Average relative humidity ≤ 75 %
RH = 95% for 30 days per year.
RH = 85% for further days limited by average value per
year, occasional slight condensation permitted.
1.6 x U
R
VDC for 2s
Max. 2% after a 2 year storage period at a temperature
of +10 ... +40°C and a relative humidity of 40...60%.
Operational life > 200 000 h.
Failure rate < 3 FIT, T = +40°C, U = 0.5 x U
R
.
Failure criteria according to DIN 44122.
0.6
0.5
0.6
0.6
0.8
0.6
0.8
0.8
0.8
0.8
0.8
1.0
1.0
20
20
± 0.4
± 0.4
30
20
± 0.4
± 0.4
30
± 0.4
30 ± 0.4
30
± 0.4
± 0.4
30
30
± 0.4
± 0.4
30
30 ± 0.4
30
± 0.7
30 ± 0.7
Z (Ω)
10
1.0
0.0
0.1
01
0.0
1
0.1
0.01
1
0.1
1.0
10
100 MHz
Capacitance drift
Reliability
Resonance frequencies
MMK 5
Z (Ω)
10
1.0
Maximum pulse
steepness:
Temperature coefficient
Self inductance
dU/dt according to article table. For peak to peak
voltages lower than rated voltage (U
pp
< U
R
), the
specified dU/dt can be multiplied by the factor U
R
/U
pp
.
+400 (±200) ppm/°C at 1 kHz
Approximately 6 nH/cm for the total length of capacitor
winding and the leads.
0.0
0.1
1
0.0
01
0.1
1.0
0.01
10
22
0.1
1.0
10
100 MHz
environMental test data
Damp heat test
Endurance test
Test conditions:
Test criteria:
Test conditions:
Test criteria:
T = +40°C, RH = 93%, t = 56 days.
∆ C/C ≤ ±5%,
∆ tanδ ≤ 0.005 (1kHz),
IR after test 0.5 x IR min.
T = +100°C, U = 1.25 x (0.8 x U
R
),
t = 2000 h.
∆ C/C ≤ ±5%,
∆ tanδ ≤ 0.005 (1kHz)
∆ tanδ ≤ 0.010 (100kHz)
IR after test 0.5 x IR min.
Resonance frequencies
MMK7.5 ... 37.5
vca822 self-excitation is serious
VCA822 has serious self-excitation. Only when the signal is above 300mvpp and the frequency is several MHz can the self-excitation signal be suppressed. TI masters, please give me a solution....
sw3926 Analogue and Mixed Signal
IAR uses printf in the standard library function
In IAR, printf() will output to the Terminal I/O window by default. To use Terminal I/O, in Debug mode, click "View-Terminal I/O". However, we can also customize the printf() function to output to UAR...
fish001 Microcontroller MCU
WM5.0 PPC cannot connect directly to SQL Server 2005 on the network. What's going on?
Help is urgent! No RDA seems to be required for sql2005 configuration, now conn.open() connection reports login failure! Tried various connection strings Standard Security: "Data Source=Aron1;Initial ...
yj3333 Embedded System
Can an expert help me compare the embedded operating systems wince, uc/os2, and linux?
I am learning embedded systems and have looked at several embedded operating systems. I would like to know their differences and connections, as well as their main applications. Could an expert please...
ersuo4s Linux and Android
Using High-Power SourceMeter to Build a Multi-Source Measurement Unit (SMU) System (Part 9): System Examples
Testing packaged devices using test fixturesKeithley 8010 High Power Device Test Fixture and2651Aas well as2657AThe 8010 high-power system digital source meter completes the power semiconductor device...
Jack_ma Test/Measurement
Newbie asks questions about smart home
I am working on a smart home project with my teacher. What do you think? Do you have any suggestions? It would be even better if there is technical support. Thank you in advance!! We are initially stu...
lzj000008 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 959  2035  400  812  1966  20  41  9  17  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号