EEWORLDEEWORLDEEWORLD

Part Number

Search

DI-8B45-07

Description
Frequency Input Modules
File Size294KB,2 Pages
ManufacturerETC
Download Datasheet Compare View All

DI-8B45-07 Overview

Frequency Input Modules

DI-8B45 Frequency Input Modules
FEATURES
• Accepts Frequency Input Signals 0 to
100kHz
• TTL or Zero-Crossing Signal Inputs
• High Level Voltage Outputs
• 1500Vrms Transformer Isolation
• ANSI/IEEE C37.90.1 Transient Pro-
tection
• Input Protected up to 240VAC Con-
tinuous
• 100dB CMR
• 70dB NMR at 60Hz
• ±0.10% Accuracy
• ±0.05% Linearity
• Low Drift with Ambient Temperature
• UL, CSA, FM and CE Certifications
Pending
• Mix and Match Module Types
SPECIFICATIONS
Input Range
Input Threshold
Typical at T
A
= +25ºC and +5V Power
DI-8B45
0Hz to 100kHz
Zero Crossing
200mVp-p
350Vp-p TTL, 170Vp-p Zero Crossing
4µs
0.8V max
2.4V min
±50mV
1.5V
200kΩ
200kΩ
200kΩ
240Vrms max
ANSI/IEEE C37.90.1
+5V at 8mA max
1500Vrms max
ANSI/IEEE C37.90.1
100dB
±0.10% Span
±0.05% Span
±25ppm/ºC
±100ppm/ºC
<10mVp-p at Input >2% Span
300ms (-01); 175ms (-02); 50ms (-03);
30ms (-04); 30ms (-05); 15ms (-06);
15ms (-07); 2ms (-08)
0 to +5V
Continuous Short to Ground
ANSI/IEEE C37.90.1
+5VDC ±5%
110mA
±50ppm/%
1.11" × 1.65" × 0.40"
(28.1mm × 41.9mm × 10.2mm)
DESCRIPTION
DI-8B modules are an optimal solution
for monitoring real-world process signals
and providing high level signals to a data
acquisition system. Each DI-8B45 module
isolates and conditions a frequency input
signal and provides an analog voltage
output.
The frequency input signal can be either
a TTL level or zero crossing with as little
as ±100mV amplitude. Input circuitry for
each signal type has built-in hysteresis to
prevent spurious noise from corrupting the
module output. TTL signals are applied to
the + and - terminals while zero crossing
signals are applied to the +EXC and - ter-
minals. Reference the block diagram (p 2).
A 5V excitation is available for use with
magnetic pick-up or contact closure type
sensors. The excitation is available on the -
EXC terminal with return on the - terminal.
A special input circuit on the DI-8B45
modules provides protection against ac-
cidental connection of power-line voltages
up to 240VAC. Clamp circuits on the I/O
and power terminals protect against harm-
ful transients.
Isolation is provided by optical coupling
to suppress transmission of common mode
spikes or surges. The module is powered
from +5VDC, ±5%.
The modules are designed for installation
in Class I, Division 2 hazardous locations
and have a high level of immunity to envi-
ronmental noise.
Minimum Input
Maximum Input
Minimum Pulse Width
TTL Input Low
TTL Input High
Input Hysteresis
Zero Crossing
TTL
Input Resistance
Normal
Power Off
Overload
Input Protection
Continuous¹
Transient
Excitation
CMV, Input to Output
Continuous
Transient
CMR (50Hz or 60Hz)
Accuracy²
Nonlinearity
Stability
Offset
Gain
Noise
Output Ripple
Response Time, 90% Span
Output Range
Output Protection
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
Mechanical Dimensions
Environmental
Transient
Operating Temperature
-40ºC to +85ºC
Storage Temperature
-40ºC to +85ºC
Relative Humidity
0 to 95% Noncondensing
¹240VAC between + and -/+EXC/-EXC terminals. 120VAC between - and +EXC/-
EXC terminals and between +EXC and -EXC terminals.
²Includes nonlinearity, hysteresis, and repeatability.
DATAQ Instruments, Inc. • 241 Springside Drive • Akron, Ohio 44333 • Tel: 330-668-1444 • Email: support@dataq.com • www.dataq.com

DI-8B45-07 Related Products

DI-8B45-07 DI-8B45 DI-8B45-01 DI-8B45-02 DI-8B45-03 DI-8B45-08 DI-8B45-05 DI-8B45-06 DI-8B45-04
Description Frequency Input Modules Frequency Input Modules Frequency Input Modules Frequency Input Modules Frequency Input Modules Frequency Input Modules Frequency Input Modules Frequency Input Modules Frequency Input Modules
WINCE serial port problem
On the arm9 platform, the application uses the serial port receiving thread to read data, and the main thread is the interface operation; the serial port data reception is normal at the beginning, but...
dqhhqd12 Embedded System
Problems encountered at work
Put it on the forum and everyone can give you some advice!...
eeleader Talking about work
Has anyone successfully applied for CC3100MOD or CC3200MOD?
Has anyone successfully applied for CC3100MOD or CC3200MOD?...
蓝雨夜 Wireless Connectivity
FY-SOPC series development board (ALTERA) CY1C6-A
[color=#000000][size=2][font=仿宋_GB2312][size=3][font=宋体]FY-SOPC series development board is aimed at multi-level users of FPGA design, and can be used as a quick-start learning platform and secondary ...
dz51fkbw Talking
Pyroelectric human body induction switch
The pyroelectric human body induction switch circuituses a pyroelectric infrared probe and amplifies the weak signal received by the probe, and then drives the relay to make a pyroelectric human body ...
rain Embedded System
Safety technology prevention standards
No. Standard Name Standard No. 1 General technical conditions for intrusion detectors GB10408.1-2000 2 Intrusion detectors - Ultrasonic Doppler detectors for indoor use GB10408.2-2000 3 Intrusion dete...
电烙铁6号 Robotics Development

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1864  434  1556  910  1188  38  9  32  19  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号