Angle Bracket, Angle Bracket Tapped, Without Angle Bracket
38330, 38336
p. 2-3
38540
p. 16-17
Shallow Bracket
38330
38542
Deep Bracket
38330, 38336
38540
p. 4-5
p. 18-19
p. 6-7
p. 20-21
Cable Mount Plugs and Sockets
Cable Clamp End
38331, 38336
38541
p. 8-9
p. 22-23
Cable Clamp Top, Cable Clamp Top with Keeper, Cable Clamp Top with Latch
38330, 38331, 38336
p. 10-11
p. 24-25
38541
Flared Hole End
38330, 38336
38540
Flared Hole Top
38330, 38331, 38336
38540
p. 12-13
p. 26-27
p. 14-15
p. 28-29
FEATURES AND SPECIFICATIONS
Features and Benefits
n
Sizes 2 to 33 circuits
n
Robust blade contacts resist damage from
improper mating
n
Large surface area of dual wipe female
contact produces maximum current
capacity
n
No de-rating required. All circuits rated for
full current load
n
Extra long pre-grounding contact engages
before any other contacts for greater safety.
Electrical
Voltage: 250V
Maximum Current:
10 Amp
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
Mechanical
Operating Temperature:
150
o
C
38330, 38336
Angled Bracket (AB)
Angle Bracket Tapped (ABT)
Less Angle Bracket (LAB)
Physical
Base Insulator: High-grade phenolic, black
Plug Contact: Brass
Plug Contact Plating: Tin
Socket Contact: Phosphor bronze
Socket Contact Plating: Tin
Pre-grounding Contact: Heavy-duty plated brass
SUGGESTED PANEL MOUNTING DIMENSIONS
CONTACT TAILS
Molex offers a wide selection of contact tails. Consult factory for
availablility and part numbers of other styles
Fig. D
Diameter
.156”
(3,96)
Reference Information
UL :
CSA:
File E34763
File 22156
.66”
(16,8)
38330-XX02
Diameter
.156”
(3,96)
.020”
(0,51)
Fig. E
.031”
(0,80)
Diameter
.156”
(3,96)
P Solder Eye (Standard)
.07” x .10”
(1,78 x 2,54)
.30”
(7,62)
.38”
(9,65)
P
7
Printed Circuit and
Wire Wrap, Short
.25”
(6,35)
.045” square
(1,14)
.97”
(24,6)
.078”
(1,98)
.44”
(11,1)
Diameter
.672”
(17,1)
38330-XX03-15
S
1
Quick Connect
.22”
(5,59)
Diameter
.156”
(3,96)
.06”
(1,59)
.44”
(11,1)
.110” x .020
(2,79 x 0,51)
P
1
Quick Connect
.39”
(9,91)
.110” x .020
(2,79 x 0,51)
Fig. F
Fig. G
Diameter
.156”
(3,96)
S Solder Eye (Standard)
.22”
(5,59)
1.015”
(25,8)
.07” x .10”
(1,78 x 2,54)
.25”
(6,35)
S
6
Printed Circuit
.10”
(2,54)
.03” x .04”
(0,76 x 1,02)
1.38”
(34,9)
38330-XX18-33
.06”
(1,59)
.032”
(0,81)
Diameter
.156”
(3,96)
1.375”
(34,9)
P
4
Wire Wrap, Long
.75” .63”
(19,1) (16,0)
.045” square
(1,14)
Diameter
.156”
(3,96)
Contact Orientation
The polarization arrangement numbers shown below are for sockets, as viewed from the wiring side. Plug numbering is the opposite. A heavy-duty polarizing/ground contact is in position 14 for Nos. 3324, 3327,
3330 and in position 17 for No. 3333. * Indicates location of pre-grounding contact. † Pregrounding contact is standard.
38330-XX02
38330-XX03
38330-XX04
38330-XX06
38336-8XXX
38330-XX08
38330-XX10
38330-XX12
38330-XX15 to 38330-XX21
38330-XX24 to 38330-XX30
38330-XX33
ORDERING INFORMATION AND DIMENSIONS
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
38330, 38336
Part #
in
3302*
3303
3304
3306
3306-8
3308
3310
3312
3315
3318
3321
3324
3327
3330
3333
0.66
1.00
0.75
1.00
1.00
1.25
1.56
1.25
1.63
1.94
2.25
2.56
2.88
3.19
3.50
T
mm
16,7
25,4
19,1
25,4
25,4
31,8
39,7
31,8
41,3
49,2
57,2
65,1
73,0
81,0
88,9
U
in
--
.44
.69
.69
.69
.69
.69
.94
1.00
1.00
1.00
1.00
1.00
1.00
1.00
V
mm
--
11,1
17,5
17,5
17,5
17,5
17,5
23,8
25,4
25,4
25,4
25,4
25,4
25,4
25,4
Part #
mm
32,1
27,0
33,3
33,3
33,3
33,3
33,3
39,7
42,9
42,9
42,9
42,9
42,9
42,9
42,9
3302*
3303
3304
3306
3306-8
3308
3310
3312
3315
3318
3321
3324
3327
3330
3333
Fig. #
in
D
E
F
E
E
F
F
F
F
G
G
G
G
G
G
.969
.750
1.000
1.000
1.000
1.000
1.000
1.250
1.375
1.250
.938
1.250
1.562
1.875
2.188
A
mm
24,6
19,1
25,4
25,4
25,4
25,4
25,4
31,8
34,9
31,8
23,8
31,8
39,7
47,6
55,6
B
in
--
1.016
.781
1.031
1.031
1.281
1.578
1.266
1.640
1.953
2.265
2.578
2.890
3.203
3.515
C
mm
--
25,8
19,8
26,2
26,2
32,5
40,1
32,2
41,7
49,6
57,5
65,5
73,4
81,4
89,3
in
1.27
1.06
1.31
1.31
1.31
1.31
1.31
1.56
1.69
1.69
1.69
1.69
1.69
1.69
1.69
in
--
.453
.719
.719
.719
.719
.719
.953
1.016
--
--
--
--
--
--
mm
--
11,5
18,3
18,3
18,3
18,3
18,3
24,2
25,8
--
--
--
--
--
--
PLUGS
Angle Bracket (-AB)
Order #
38330-0102
38330-0103
38330-0104
38330-0106
38336-8001
38330-0108
38330-0110
38330-0112
38330-0115
38330-0118
38330-0121
38330-0124
38330-0127
38330-0130
38330-0133
Engineering #
P-3302-AB
P-3303-AB
P-3304-AB
P-3306-AB
P-3306-8-AB
P-3308-AB
P-3310-AB
P-3312-AB
P-3315-AB
P-3318-AB
P-3321-AB
P-3324-AB
P-3327-AB
P-3330-AB
P-3333-AB
Angle Bracket Tapped (-ABT)
Order #
38330-1502
38330-1503
38330-1504
38330-1506
38336-8015
38330-1508
38330-1510
38330-1512
38330-1515
38330-1518
38330-1521
38330-1524
38330-1527
38330-1530
38330-1533
Engineering #
P-3302-ABT
P-3303-ABT
P-3304-ABT
P-3306-ABT
P-3306-8-ABT
P-3308-ABT
P-3310-ABT
P-3312-ABT
P-3315-ABT
P-3318-ABT
P-3321-ABT
P-3324-ABT
P-3327-ABT
P-3330-ABT
P-3333-ABT
Less Angle Bracket (-LAB)
Order #
38330-2202
38330-2203
38330-2204
38330-2206
38336-8022
38330-2208
38330-2210
38330-2212
38330-2215
38330-2218
38330-2221
38330-2224
38330-2227
38330-2230
38330-2233
Engineering #
P-3302-LAB
P-3303-LAB
P-3304-LAB
P-3306-LAB
P-3306-8-LAB
P-3308-LAB
P-3310-LAB
P-3312-LAB
P-3315-LAB
P-3318-LAB
P-3321-LAB
P-3324-LAB
P-3327-LAB
P-3330-LAB
P-3333-LAB
SOCKETS
Angle Bracket (-AB)
Order #
38330-0502
38330-0503
38330-0504
38330-0506
38336-8005
38330-0508
38330-0510
38330-0512
38330-0515
38330-0518
38330-0521
38330-0524
38330-0527
38330-0530
38330-0533
Engineering #
S-3302-AB
S-3303-AB
S-3304-AB
S-3306-AB
S-3306-8-AB
S-3308-AB
S-3310-AB
S-3312-AB
S-3315-AB
S-3318-AB
S-3321-AB
S-3324-AB
S-3327-AB
S-3330-AB
S-3333-AB
Angle Bracket Tapped (-ABT)
Order #
38330-1902
38330-1903
38330-1904
38330-1906
38336-8019
38330-1908
38330-1910
38330-1912
38330-1915
38330-1918
38330-1921
38330-1924
38330-1927
38330-1930
38330-1933
Engineering #
S-3302-ABT
S-3303-ABT
S-3304-ABT
S-3306-ABT
S-3306-8-ABT
S-3308-ABT
S-3310-ABT
S-3312-ABT
S-3315-ABT
S-3318-ABT
S-3321-ABT
S-3324-ABT
S-3327-ABT
S-3330-ABT
S-3333-ABT
Less Angle Bracket (-LAB)
Order #
38330-2602
38330-2603
38330-2604
38330-2606
38336-8026
38330-2608
38330-2610
38330-2612
38330-2615
38330-2618
38330-2621
38330-2624
38330-2627
38330-2630
38330-2633
Engineering #
S-3302-LAB
S-3303-LAB
S-3304-LAB
S-3306-LAB
S-3306-8-LAB
S-3308-LAB
S-3310-LAB
S-3312-LAB
S-3315-LAB
S-3318-LAB
S-3321-LAB
S-3324-LAB
S-3327-LAB
S-3330-LAB
S-3333-LAB
FEATURES AND SPECIFICATIONS
Features and Benefits
n
Sizes 15 to 33 circuits
n
Robust blade contacts resist damage
fromimproper mating
n
Large surface area of dual wipe female
contact produces maximum current
capacity
n
No de-rating required. All circuits rated
for full current load
n
Extra long pre-grounding contact
engages before any other contacts for
greater safety.
Electrical
Voltage: 250V
Maximum Current: 10 Amp
Beau
TM
Power Connectors
Panel Mount Plugs and Sockets
Mechanical
Operating Temperature:
150
o
C
38330
Shallow Bracket (SB)
Physical
Base Insulator:High-grade phenolic, black
Plug Contact: Brass
Plug Contact Plating: Tin
Socket Contact: Phosphor bronze
Socket Contact Plating: Tin
Pre-grounding Contact: Heavy-duty plated brass
SUGGESTED PANEL MOUNTING DIMENSIONS
CONTACT TAILS
Molex offers a wide selection of contact tails. Consult factory for
availablility and part numbers of other styles
Reference Information
UL :
CSA:
File E34763
File 22156
.032”
(0,81)
Fig. K
1.08”
(27.4)
P Solder Eye (Standard)
.07” x .10”
(1,78 x 2,54)
.30”
(7,62)
P
7
Printed Circuit and
Wire Wrap, Short
.25”
(6,35)
.38”
(9,65)
.045” square
(1,14)
1.38”
(34.9)
.44”
(11,1)
Diameter
.187”
(4,75)
S
1
Quick Connect
.22”
(5,59)
.110” x .020
(2,79 x 0,51)
P
1
Quick Connect
.39”
(9,91)
.110” x .020
(2,79 x 0,51)
S Solder Eye (Standard)
.22”
(5,59)
Diameter
.190”
(4.83)
.07” x .10”
(1,78 x 2,54)
.25”
(6,35)
S
6
Printed Circuit
.10”
(2,54)
.03” x .04”
(0,76 x 1,02)
P
4
Wire Wrap, Long
.75” .63”
(19,1) (16,0)
.045” square
(1,14)
Contact Orientation
The polarization arrangement numbers shown below are for sockets, as viewed from the wiring side. Plug numbering is the opposite. A heavy-duty polarizing/ground contact is in position 14 for Nos. 3324, 3327,
Just use the keypad to input any number from 0000 to 9999, and then separate them with ., and then save them. The maximum number of numbers that can be saved is about 50, and the LED is used for displ...
After the project code is compiled, the following information is printed:
Info: Clock "CLK48M" has Internalfmax of 67.47 MHz between source register "GLUE_LGC:glue|MCLK" and destination register "img_...
I spent about a week getting familiar with the LM3S8962 EVALUATION BOARD on the forum. This board has some unique features, such as simple peripheral architecture, configurable GPIO driver capability,...
I would like to ask experts to recommend a few triple SPDT analog switches with smaller Ron and ΔR. I am using ADG1433, but since 1433 is affected by the power-on sequence, I need to replace it. Pleas...
Excuse me, if I use the cc2430 chip for development, does the antenna part need high-frequency design? Is there any ready-made antenna that does not require high-frequency design?...
Most of the houses we live in now are elevator buildings, mainly because it is more convenient to go up and down the stairs! It can also make life more comfortable. It even helps to increase the ad...[Details]
To understand why car engines need gearboxes, we must first understand the characteristics of different types of engines. An engine refers to a machine that can convert a form of energy into kineti...[Details]
Logic analyzers are widely used tools in digital design verification and debugging. They can verify the proper functioning of digital circuits and help users identify and troubleshoot faults. They ...[Details]
White light LEDs are voltage-sensitive devices. In actual operation, their upper limit is 20mA. However, the current often increases due to various reasons during use. If no protective measures are...[Details]
The Automotive Testing and Quality Assurance Expo (ATE 2025) will open on August 27th. At the expo, Rohde & Schwarz (R&S) will showcase six automotive testing solutions, themed "Intelligently Drivi...[Details]
On August 22, according to the Ministry of Industry and Information Technology's official website, my country's first mandatory national standard for the control of hazardous substances in electric...[Details]
introduction
According to the China Fire Statistics Yearbook, electrical fires accounted for more than 30% of fire accidents in the past decade, and the trend is increasing year by year. They ...[Details]
Tires are a very important component for cars. They are related to the driving experience of the vehicle. We are almost inseparable from cars in our daily lives. For tires, according to the role of...[Details]
Coal mines typically contain gas and coal dust. When gas and coal dust reach a certain concentration, they can cause explosions. Electrical equipment generates arcs during normal operation or durin...[Details]
Bosch has released a new SoC series to support L2+ advanced driver assistance functions. The chip integrates high resolution and long-range detection capabilities, and has built-in support for neur...[Details]
There are many motors that can use thyristor speed control, and they can be used in almost all industries. Various types of motors, such as fans, pumps, AC motors, DC motors, torque motors, single-...[Details]
Smartphones can be incredibly unintelligent. For example, consider an office full of people, each absorbed in their work. Suddenly, the silence is broken by a burst of loud pop music. A colleague's...[Details]
AI distributed rendering architecture improves mobile phone rendering capabilities, and game performance tests can check frame generation indicators in real time
Shanghai, China, Aug...[Details]
According to Reuters, citing people familiar with the matter, British semiconductor design company Arm Holdings (NASDAQ:ARM) has hired Rami Sinno, head of Amazon's (NASDAQ:AMZN) artificial intellig...[Details]
Driven by business opportunities such as access to new markets and government initiatives like the Belt and Road Initiative, global expansion has become a significant trend for Chinese companies. C...[Details]