EEWORLDEEWORLDEEWORLD

Part Number

Search

3120-F321-H7M1-W01F-16A

Description
Circuit Breakers Thermal-magnetic circuit breaker, 16A, 240VAC, 50VDC, Black Rocker, Non-Illuminated, VDE, UL, CSA, CCC, CQC
CategoryCircuit protection   
File Size324KB,6 Pages
ManufacturerE-T-A Circuit Breakers
Environmental Compliance
Download Datasheet Parametric Compare View All

3120-F321-H7M1-W01F-16A Online Shopping

Suppliers Part Number Price MOQ In stock  
3120-F321-H7M1-W01F-16A - - View Buy Now

3120-F321-H7M1-W01F-16A Overview

Circuit Breakers Thermal-magnetic circuit breaker, 16A, 240VAC, 50VDC, Black Rocker, Non-Illuminated, VDE, UL, CSA, CCC, CQC

3120-F321-H7M1-W01F-16A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A Circuit Breakers
Product CategoryCircuit Breakers
RoHSDetails
ProductCircuit Breakers
TypeThermal-Magnetic Circuit Breaker
Current Rating16 A
Voltage Rating AC240 VAC
Voltage Rating DC50 VDC
Number of Poles2 Pole
Actuator TypeRocker
Minimum Operating Temperature- 30 C
Maximum Operating Temperature+ 60 C
IlluminatedNot Illuminated
Height25 mm
Length65 mm
Termination StyleBlade
Voltage Rating50 VDC, 240 VAC
Width41 mm
Mounting StyleSnap In
Thermal-Magnetic Circuit Breaker 3120-...-M1-...
Description
Two pole rocker switch/thermal-magnetic circuit breaker with trip-free
mechanism (S-type TM CBE to EN 60934). The addition of a magnetic
tripping module to the type 3120 range described in catalogue section
Thermal Overcurrent Circuit Breakers extends the choices available
(thermal-magnetic protection in pole 1, thermal or no protection in
pole 2). All are offered with rocker switch or push button control - two
buttons for ON/OFF or one button press-to-reset only, in designs to
suit one of three different panel cut-out sizes. Illumination is optional.
Approved to CBE standard EN 60934 (IEC 60934).
Meets the requirements regarding fire resistance of EN 60335-1: 2007-02
Safety of household and similar electrical appliances.
1
3120-...-M...
Technical data
For further details please
Voltage rating
Current ratings
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A)
see chapter: Technical Information
AC 240 V (50/60 Hz); DC 50 V
0.1...16 A
0.1...16 A 50,000 operations at 1 x I
N
, ind.
-30...+60 °C (-22...+140 °F)
rated impulse
pollution
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
test voltage
AC 3,000 V
AC 1,500 V
> 100 MΩ (DC 500 V)
AC 0.1...2 A 100 x I
N
AC 2.5...16 A 250 A
DC 0.1...16 A 10 x I
N
Typical applications
Motors, machine tools, office equipment, appliances.
Standard current ratings and typical internal resistance values
Current ratings (A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
3.5
4
5
6
7
8
10
12
14
15
16
Internal resistance per pole (Ω)
thermal-magnetic
165
42.5
20.2
9.7
7.17
4.9
2.65
1.49
1.25
0.74
0.49
0.20
0.14
0.114
0.092
0.06
0.043
0.030
0.029
0.021
< 0.02
< 0.02
< 0.02
< 0.02
thermal
94
24
12
5.40
4.30
3
1.50
0.9
0.7
0.45
0.29
0.0785
0.0595
0.0565
0.0435
0.0325
0.0215
0.0215
0.02
0.02
< 0.02
< 0.02
< 0.02
< 0.02
Dielectric strength
(IEC 60664 and 60664A)
operating area
current path/current path
Insulation resistance
Interrupting capacity I
cn
Interrupting capacity
(UL 1077)
I
N
0.1...10 A
0.1...16 A
Degree of protection
(IEC 60529/DIN 40050)
Vibration
U
N
AC 250 V
DC 125 V
I
nc
2,000 A
1,000 A
Shock
Corrosion
Humidity
Mass
operating area IP40
(with water splash protection IP54)
terminal area IP00
8 g (57-500 Hz) ± 0.61 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 53 g (2-pole)
approx. 50 g (1-pole)
Illumination voltage / Power consumption
Operating voltage
230 V
Power consumption
Y
2.2 mA
R
0.9 mA
G
0.9 mA
1806
www.e-t-a.de
1

3120-F321-H7M1-W01F-16A Related Products

3120-F321-H7M1-W01F-16A 3120-F321-P7M1-W01A-2.5A
Description Circuit Breakers Thermal-magnetic circuit breaker, 16A, 240VAC, 50VDC, Black Rocker, Non-Illuminated, VDE, UL, CSA, CCC, CQC Circuit Breakers
Product Attribute Attribute Value Attribute Value
Manufacturer E-T-A Circuit Breakers E-T-A Circuit Breakers
Product Category Circuit Breakers Circuit Breakers
Product Circuit Breakers Circuit Breakers
Type Thermal-Magnetic Circuit Breaker Thermal Overcurrent Circuit Breaker
Current Rating 16 A 2.5 A
Voltage Rating AC 240 VAC 240 VAC
Voltage Rating DC 50 VDC 50 VDC
Number of Poles 2 Pole 2 Pole
Actuator Type Rocker Rocker
Minimum Operating Temperature - 30 C - 30 C
Maximum Operating Temperature + 60 C + 60 C
Illuminated Not Illuminated Not Illuminated
Height 25 mm 21 mm
Length 65 mm 41 mm
Termination Style Blade Blade
Voltage Rating 50 VDC, 240 VAC 50 VDC, 240 VAC
Width 41 mm 33 mm
Mounting Style Snap In Snap In
RIGOL DS1000Z series oscilloscope, starting at 3980 yuan!
[font=微软雅黑][size=6]For more details, please click: >>[/size][/font][url=http://www.rigol.com/recommend/ds1000z.php?returnurl=bbs.eeworld.com.cn][size=6][color=Red][b]DS1000Z Series Digital Oscilloscop...
EEWORLD社区 Test/Measurement
Attenuation problem of many Zigbee sub-nodes
Recently, I have set up a star topology structure, with one ZIGBEE master node and 6 ZIGBEE sub-node receiving ends. The network is often disconnected. After restarting, it can be reconnected to the I...
LJ_Blackhorse RF/Wirelessly
OMAP-L138 ARM+DSP dual-core development courseware and HD video
[size=4]Watch link: digoboy.com/video/20.html[/size]...
llr12345 ARM Technology
Unicode preservation issues
Everyone, when Chinese characters are saved in Unicode to txt, they appear as garbled characters on a PC. So is it possible to make the numbers look normal in the browser in wince, but appear as garbl...
qddianzi Embedded System
Switching power converter working mode--COT fixed on-time mode
[i=s] This post was last edited by Yue Yixue on 2016-10-20 11:49[/i] [p=null, 0, left][color=rgb(62, 62, 62)][b]Foreword[/b][/color][/p][p=null, 2, left][color=rgb(62, 62, 62)]The working principles o...
月亦雪 Integrated technical exchanges
Research Projects
I'm new to MCU and EDA, but the institute requires me to do a research project on them, so I'm very confused and don't know what to do. I hope you can give me some advice and provide some projects, pr...
baiyun555 Robotics Development

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2195  2047  2805  503  2363  45  42  57  11  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号