EEWORLDEEWORLDEEWORLD

Part Number

Search

4230-T120-K0CU-40A

Description
Circuit Breakers MCB, UL489, 2P, DM, 240VAC/60VDC, C, 40A
CategoryCircuit protection   
File Size1MB,12 Pages
ManufacturerE-T-A Circuit Breakers
Environmental Compliance
Download Datasheet Parametric View All

4230-T120-K0CU-40A Online Shopping

Suppliers Part Number Price MOQ In stock  
4230-T120-K0CU-40A - - View Buy Now

4230-T120-K0CU-40A Overview

Circuit Breakers MCB, UL489, 2P, DM, 240VAC/60VDC, C, 40A

4230-T120-K0CU-40A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A Circuit Breakers
Product CategoryCircuit Breakers
RoHSDetails
TypeMiniature
Current Rating40 A
Voltage Rating AC480 VAC
Voltage Rating DC60 VDC
Number of Poles2 Pole
Actuator TypeToggle
Minimum Operating Temperature- 35 C
Maximum Operating Temperature+ 70 C
IlluminatedNot Illuminated
Termination StyleScrew
Voltage Rating60 VDC
Mounting StyleDIN Rail
Factory Pack Quantity1
Thermal-magnetic Miniature Circuit Breaker 4230-T...
Description
Single pole and multipole thermal-magnetic miniature circuit breakers
(MCBs) in accordance with EN 60947-2, UL 1077 and UL 489 for
DIN rail mounting, with toggle actuation, visual status indication and
high rupture capacity. A positively trip-free snap action mechanism
ensures reliable switching behaviour. A range of trip characteristics
and add-on modules allow a great variety of applications.
Typical applications
Protection of cables, motors, generators and transformers, thyristors
and silicon rectifiers. Protection of computers and their peripheral
equipment, industrial process control systems, telecommunications
equipment, power supplies.
UL 489 version
4230-T...
1
IEC/EN60947-2 & UL1077 version
Technical Data
Voltage rating and current rating range
to IEC/EN 60947-2
1-pole: AC 240 V; 1 A…63 A;
2, 3, 4-pole: AC 415 V, 1 A…63 A;
1-pole: DC 80 V, 1 A...63 A
2-pole: (2 poles connected in series)
DC 125 V, 1...63 A
1-pole: AC 277 V; 1 A…63 A;
2, 3, 4-pole: AC 480Y/277 V, 1 A…63 A;
1-pole: DC 60 V; 1 A...63 A;
2-pole (2 poles connected in series):
DC 125 V; 1 A...63 A;
1-pole: AC 120 V; 1A…63 A;
2, 3-pole: AC 240 V, 1 A…63 A;
1-pole: AC 277 V; 1 A…32 A;
2, 3-pole: AC 480Y/277 V; 1 A…32 A;
1-pole: DC 60 V; 1 A…63 A;
2-pole (2 poles connected in series);
DC 125 V; 1 A…63 A;
20,000 cycles
6,000 cycles
Technical Data
Rupture capacity
to IEC/EN 60947-2 (Ics)
to IEC/EN 60947-2
(Icu)
to UL 489
to UL1077
Number of
poles
1-pole
1-pole
2-, 3-,
4-pole
1-pole
2-pole in
series
Un
AC 240 V
AC 277 V
AC 480 V
DC 60 V
DC 125 V
In
AC 7,500 A / DC 10,000 A
AC/DC 10,000 A
AC/DC 10,000 A
TC
1
1
1
1
1
OL
1
0
1
0
0
SC
7.5 kA, U1
5 kA, U1
5 kA, U1
7.5 kA, U1
7.5 kA, U1
to UL 1077
to UL 489
1...63 A
1...63 A
1...63 A
1...63 A
1...63 A
Typical life
Mechanically
Electrically
Insulation coordination
Degree of protection
Vibration (sinusoidal)
test to IEC 60068-2-6,
test Fc
Shock, test to
IEC 60068-2-27, test Ea
Corrosion, test to IEC
60068-2-11, test Ka
Humidity, test to IEC
60068-2-78, test Cab
Terminals
6 kV/3 (reinforced insulation
at operating area)
IP20
± 0.38 mm (10–57 Hz), 5 g
(57–500 Hz)
10 frequency cycles per axis
30 g (11 ms)
96 hrs in 5% salt mist
48 hours at 95% RH,
temperature +40°C
screw terminals
Vertical connection possible
by means of busbars
2 Nm max.
≤35 mm²
-35°C...+ 70°C
rail mounting
approx. 116 g per pole (EN 60947-2/
UL 1077) approx. 131 g per pole
(UL 489)
Approvals
Approval
authority
TÜV
Standard
IEC/EN
60947-2
Rated voltage
AC 240/415 V
DC 80 V
DC 125 V
AC 480Y/277 V
DC 60 V
DC 125 V
AC 240 V
AC 480Y/277 V
DC 60 V
DC 125 V
Current ratings
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...32 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
UL
UL 1077 /
CSA-C22.2
No. 235
UL 489 /
CSA-C22.2
No. 5
UL
Tightening torque
Cable cross section
Ambient temperature:
Mounting
Mass
1638
www.e-t-a.de
1
EEWORLD University ---- Chopper Circuit (1) - Overview and Principle of Buck Chopper Circuit
Chopper Circuit (1) - Overview and Principle of Buck Chopper Circuit : https://training.eeworld.com.cn/course/2271...
hi5 Analogue and Mixed Signal
SolidWorks with AD9 to design special-shaped PCB board steps
[align=left][color=rgb(51, 51, 51)]Author: caterwang[/color][/align][align=left][color=rgb(51, 51, 51)]When designing PCB, not every PCB board is a regular square or round shape. There may be various ...
木犯001号 PCB Design
Paradox between power control accuracy and time delay accuracy of zero-crossing switch
[i=s]This post was last edited by shipeng on 2020-7-22 11:04[/i]I have been using PID temperature control for almost 4 years, and there is a problem that has been bothering me until now. I used to thi...
shipeng MCU
Locke's Law
Locke's Law means: When a goal is both future-oriented and challenging, it is most effective. You can set a high overall goal for yourself, but you must set a more important step to implement the goal...
白丁 Talking
Button Priority Application
#includereg52.h void debouncer(void);void delay10ms(int);void alter(int);void left(int);void right(int);void pili(int);void flash(int);void debouncer(void){int i;for(i=0;i2400;i++);} void delay10ms(in...
guoyuanqiang MCU
Relax on the weekend
[url=http://www.miaopai.com/show/4l4Lo55sAxJi6RM1MmhQcg__.htm]This is a video link[/url]...
白丁 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1156  2279  2221  731  1302  24  46  45  15  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号