EEWORLDEEWORLDEEWORLD

Part Number

Search

4230-T120-K0BE-35A

Description
Circuit Breakers 1077, 2P, DM, 480VAC/60VDC, B, 35A
CategoryCircuit protection   
File Size1MB,12 Pages
ManufacturerE-T-A Circuit Breakers
Environmental Compliance
Download Datasheet Parametric View All

4230-T120-K0BE-35A Online Shopping

Suppliers Part Number Price MOQ In stock  
4230-T120-K0BE-35A - - View Buy Now

4230-T120-K0BE-35A Overview

Circuit Breakers 1077, 2P, DM, 480VAC/60VDC, B, 35A

4230-T120-K0BE-35A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A Circuit Breakers
Product CategoryCircuit Breakers
RoHSDetails
Factory Pack Quantity1
Thermal-magnetic Miniature Circuit Breaker 4230-T...
Description
Single pole and multipole thermal-magnetic miniature circuit breakers
(MCBs) in accordance with EN 60947-2, UL 1077 and UL 489 for
DIN rail mounting, with toggle actuation, visual status indication and
high rupture capacity. A positively trip-free snap action mechanism
ensures reliable switching behaviour. A range of trip characteristics
and add-on modules allow a great variety of applications.
Typical applications
Protection of cables, motors, generators and transformers, thyristors
and silicon rectifiers. Protection of computers and their peripheral
equipment, industrial process control systems, telecommunications
equipment, power supplies.
UL 489 version
4230-T...
1
IEC/EN60947-2 & UL1077 version
Technical Data
Voltage rating and current rating range
to IEC/EN 60947-2
1-pole: AC 240 V; 1 A…63 A;
2, 3, 4-pole: AC 415 V, 1 A…63 A;
1-pole: DC 80 V, 1 A...63 A
2-pole: (2 poles connected in series)
DC 125 V, 1...63 A
1-pole: AC 277 V; 1 A…63 A;
2, 3, 4-pole: AC 480Y/277 V, 1 A…63 A;
1-pole: DC 60 V; 1 A...63 A;
2-pole (2 poles connected in series):
DC 125 V; 1 A...63 A;
1-pole: AC 120 V; 1A…63 A;
2, 3-pole: AC 240 V, 1 A…63 A;
1-pole: AC 277 V; 1 A…32 A;
2, 3-pole: AC 480Y/277 V; 1 A…32 A;
1-pole: DC 60 V; 1 A…63 A;
2-pole (2 poles connected in series);
DC 125 V; 1 A…63 A;
20,000 cycles
6,000 cycles
Technical Data
Rupture capacity
to IEC/EN 60947-2 (Ics)
to IEC/EN 60947-2
(Icu)
to UL 489
to UL1077
Number of
poles
1-pole
1-pole
2-, 3-,
4-pole
1-pole
2-pole in
series
Un
AC 240 V
AC 277 V
AC 480 V
DC 60 V
DC 125 V
In
AC 7,500 A / DC 10,000 A
AC/DC 10,000 A
AC/DC 10,000 A
TC
1
1
1
1
1
OL
1
0
1
0
0
SC
7.5 kA, U1
5 kA, U1
5 kA, U1
7.5 kA, U1
7.5 kA, U1
to UL 1077
to UL 489
1...63 A
1...63 A
1...63 A
1...63 A
1...63 A
Typical life
Mechanically
Electrically
Insulation coordination
Degree of protection
Vibration (sinusoidal)
test to IEC 60068-2-6,
test Fc
Shock, test to
IEC 60068-2-27, test Ea
Corrosion, test to IEC
60068-2-11, test Ka
Humidity, test to IEC
60068-2-78, test Cab
Terminals
6 kV/3 (reinforced insulation
at operating area)
IP20
± 0.38 mm (10–57 Hz), 5 g
(57–500 Hz)
10 frequency cycles per axis
30 g (11 ms)
96 hrs in 5% salt mist
48 hours at 95% RH,
temperature +40°C
screw terminals
Vertical connection possible
by means of busbars
2 Nm max.
≤35 mm²
-35°C...+ 70°C
rail mounting
approx. 116 g per pole (EN 60947-2/
UL 1077) approx. 131 g per pole
(UL 489)
Approvals
Approval
authority
TÜV
Standard
IEC/EN
60947-2
Rated voltage
AC 240/415 V
DC 80 V
DC 125 V
AC 480Y/277 V
DC 60 V
DC 125 V
AC 240 V
AC 480Y/277 V
DC 60 V
DC 125 V
Current ratings
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...32 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
UL
UL 1077 /
CSA-C22.2
No. 235
UL 489 /
CSA-C22.2
No. 5
UL
Tightening torque
Cable cross section
Ambient temperature:
Mounting
Mass
1638
www.e-t-a.de
1
Reading "Time as a Friend" (V): Is interest really that important?
Original text: Students often tell me that they are not interested in their current majors, and what they are really interested in is a certain major. —— As we often see, these people are unhappy. Bec...
向农 Talking about work
Commonly used inductors and transformers testing experience
1. Testing of color-coded inductors Set the multimeter to R×1, connect the red and black test leads to any lead of the color-coded inductor, and the pointer should swing to the right. According to the...
逍遥 Test/Measurement
The difference between RS232, RS422 and RS485
1. RS-232-CRS-232-C is a serial physical interface standard developed by the Electronic Industry Association (EIA) of the United States. RS is the abbreviation of "Recommended Standard", 232 is the id...
totopper Industrial Control Electronics
Problems with reading and writing 93C46 with msp430g2553
I use LANUCHPAD to read and write 93C46, but it is unsuccessful. The program is as follows, please give me some advice, thank you! #include "msp430g2553.h" unsigned char MST_Data,SLV_Data; int main( v...
chenbingjy Microcontroller MCU
Raspberry Pi Pico Windows Development Environment - Compile and build projects under the command line
This is what I did beforeRaspberry Pi Pico Windows Development Environment - Compile and build projects under the command lineBuilding from the command lineConfigure SDK pathOpen a Developer Command P...
gao_hex Creative Market
My problem!
I want to ask, brothers! What is the main purpose of electronic engineers learning ARM? Do they need to learn Linux or WinCE? And do embedded software engineers also need to understand ARM? They are m...
lecat Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1374  227  1944  1  2415  28  5  40  1  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号