Part Number

Search

8345-C24A-U3T2-DB1B2B-100A

Description
Circuit Breakers
CategoryCircuit protection   
File Size700KB,10 Pages
ManufacturerE-T-A Circuit Breakers
Download Datasheet Parametric View All

8345-C24A-U3T2-DB1B2B-100A Online Shopping

Suppliers Part Number Price MOQ In stock  
8345-C24A-U3T2-DB1B2B-100A - - View Buy Now

8345-C24A-U3T2-DB1B2B-100A Overview

Circuit Breakers

8345-C24A-U3T2-DB1B2B-100A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A Circuit Breakers
Product CategoryCircuit Breakers
ProductHydraulic Magnetic Circuit Breakers
Current Rating100 A
Number of Poles4 Pole
Actuator TypeLever
Minimum Operating Temperature- 40 C
Maximum Operating Temperature+ 85 C
IlluminatedNot Illuminated
Length63.5 mm
Termination StyleThreaded Stud
Width48 mm
Mounting StyleFlange
Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-...
Description
Single or multipole hydraulic-magnetic circuit breakers with trip-free-
mechanism and toggle actuation. A choice of switching characteristics
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Auxiliary contacts optional. Low
temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934) S-type HM CBE.
Typical applications
In the business fields Communication and Transport: power supplies,
switchgear, instrumentation and process control engineering.
1-pole
Standard current ratings and typical internal resistance values
Current
rating (A)
0,05
0,1
1
2
3
5
10
15
20
25
30
40
50
60
80
100
125
Trip curves and internal resistance (Ω) per pole
F1
---
---
0,578
0,144
0,0644
0,0250
0,00901
0,00597
0,00468
0,00410
0,00385
0,00371
0,00358
---
---
---
---
---
---
0,347
0,0959
0,0477
0,0192
0,00714
0,00483
0,00410
0,00385
0,00371
0,00371
0,00358
---
---
---
---
F2
K1, M1, T1
531
129
1,10
0,295
0,121
0,0437
0,0147
0,00794
0,00597
0,00456
0,00458
0,00373
0,00335
0,00333
0,00325
0,00316
0,00314
K2, M2, T2
542
127
1,08
0,291
0,118
0,0449
0,0133
0,00794
0,00597
0,00456
0,00458
0,00373
0,00335
0,00333
0,00325
0,00316
0,00314
8345
1
2-pole
Technical data
Voltage rating
3 AC 415 V; AC 277/480 V;
AC 120/240 V; AC 240 V; DC 80 V
(higher DC voltages to special order)
0.02...125 A single and multipole
higher ratings upon request
AC 240 V 6 A
DC 28 V 3 A
DC 65 V 1 A
DC 80 V 0.5 A
10,000 operations at 1 x I
N
-40...+85 °C (-40...+185 °F)
2.5 kV/2
reinforced insulation in operating area
test
test
test
test
test
voltage
voltage
voltage
voltage
voltage
AC
AC
AC
AC
AC
3,000
1,500
1,500
3,000
1,500
V
V
V
V
V
Current rating range
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664)
Dielectric strength
operating area
Line to Load
pole to pole
(2- and 3-pole)
main to auxiliary circuit
switching to trip circuit
(version -X)
Insulation resistance
Degree of protection
(IEC 60529)
Vibration
mounting attitude
toggle down:
other mounting attitudes:
with curves F1, F2:
> 100 MΩ (DC 500 V)
operating area IP40
terminal area IP00
10 g (57-2000 Hz) ± 0,76 mm (10-57 Hz)
at 0.9 x I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all mounting attitudes
(57-2000 Hz) ± 0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
,
100 g (11 ms) at 0.8 x I
N
,
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 90 - 120 g per pole
depending on version
Interrupting capacity
to EN 60934, CCC, UL 489, UL 1077
IEC 60934 / CCC (3-pole) – test series E:
voltage
DC 80 V
AC 240/415 V
AC 240 V
voltage
DC 80 V
AC 120 V
AC 120/240 V
AC 240 V
voltage
DC 80 V
AC 277/480 V
number of
poles
1+2
1–4
1
number of
poles
1+2
1
1 (2)
1
UL 1077:
number of
poles
1+2
1–4
I
N
max. (A)
0.02...125
0.02...70
I
cn
(A)
10 000
5 000
I
N
max. (A)
0.02...125
0.016...80
0.016...20
I
N
max. (A)
0.5...125
0.5...80
0.5...80
0.5...20
I
cn
(A)
10 000
6 x I
N
5 000
I
cn
(A)
10 000
5 000
5 000
5 000
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
UL 489 – test sequence Z:
1801
www.e-t-a.de
1
Please give me some advice on how to learn embedded development
I have just started learning embedded software development, please give me some advice...
genghui Embedded System
Interface design between MSP430 and NAND_FLASH
MSP430 and NAND_FLASH interface design...
灞波儿奔 Microcontroller MCU
Fujitsu FM3 Application Notes and Sample Code
Application Notes and Sample Code SoftwareOSNo. Product Serial Title Description Application Notes Sanple CodeMN706-00001-1v0-E 32bit Microcontroller FM3 Family Application Note FM3 Family uT-Kernel S...
littleshrimp DIY/Open Source Hardware
Automatically generate DSP code and test methods in the new version of MATLAB and CCS5.x
In the past, I have been introducing some traditional DSP program development methods to forum members, including firmware-based DSP development methods. Today, I will introduce the model-based DSP co...
平湖秋月 Microcontroller MCU
[Show off] My CC2650STK has arrived, and I'll post some DevPack information
I won't say anything, just the picturesI bought the DevPack, I never thought the connector to connect with stk is so mini, luckily I bought it. Otherwise I don't know how to debug.The same black immer...
人民币的幻想 Wireless Connectivity
Does anyone have a production process flow chart for an electronics processing plant?
Does anyone have a production process flow chart for an electronics processing plant? Could you please send me a copy? hgh0513@126.com xie xie...
hgh0513 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 566  579  1400  89  1061  12  29  2  22  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号