Specifically designed for electro-surgical catheter applications, the compact
and cost effective PL-900 Series offers more features, contacts, and termination
options than the competition.
Pulse-Lok®
auto-latch / mating confirmation
Packaging (intuitive, compact, configurable)
mechanism confirms continuity in critical surgical
applications
14 standard color combinations
Proprietary keying protects your single-use from
being copied, or mated with the wrong connector
Custom configurations including passive and active
devices for coding or limiting catheter usage
Performance (for harsh environments)
Water proof (IP-67 rated)
Sterilizable
Chemical resistant housing
Up to 5,000 mating cycles (with std.Contacts)
Factory terminated, overmolded cable
assemblies for enhanced flex and stain relief
SPECIFICATIONS
Electrical (see below)
Mating Life: 5,000 cycles min.
Contact Resistance: < 10 milliohms*
Material
Connector Housing: Thermoplastic
Flex Reliefs: Thermoplastic Rubber
Contacts/Sockets: Brass / BeCu,
Gold Plate per MIL-G-45204
Reusable Socket = 30-45µ” Gold over 50-
200µ” Nickel strike
Disposable Pin = 10-30µ” Gold over 50-200µ”
Nickel strike
Mechanical
Mating Cycles: 5K cycles max
Retention Force:
Mated Connectors: 50 lbs. Minimum
Cable to Connector: 50 lbs. Typical
Backshell to Connector: 50 lbs. Minimum
Environmental
Operating Temp:
-20C
to +85C**
Moisture Resistance: to IP-67 (encapsulated)
Sterilizable: gamma, EtO & Autoclave
Chem. Resistance: common OR cleaning solvents
Shelf Life: 3 years (min) Disposable Connectors
* post conditioning
**Dependent on overmold material
TABLE A:
Number of
Poles
52
41
35
28
24
24
17
15
11
9
STANDARD CONTACT CONFIGURATIONS & SPECFICATIONS
Up to 52 Contact
Positions
Contact Size
Pin
φ
(mm)
0.5
0.5
0.5
0.5
0.5
0.7
0.5
0.7
0.5
0.7
Max Wire
Gauge
26
22
26
26
26
22
26
22
26
22
Operating
Operating Current
Voltage Max
Max (A)
300 V RMS
300 V RMS
300 V RMS
300 V RMS
300 V RMS
300 V RMS
300 V RMS
300 V RMS
300 V RMS
300 V RMS
2.0
2.0
2.0
2.0
2.0
5.0
2.0
5.0
2.0
5.0
Contact
Resistance
(ohms)
<10m
<10m
<10m
<10m
<10m
<10m
<10m
<10m
<10m
<10m
Custom contact inserts are available. Consult factory.
Disposable Receptacle Assembly
.90φ
Rear Panel-Mount
Receptacle Assembly
0.460 typ.
STANDARD HOUSING OPTIONS
.90φ
In-Line Plug Assembly
2.37
Shown with optional backshell (See Table C)
1.00φ
2.90
Showm with Overmolded Strain Relief
Disposable Receptacle
1.02
In-Line Plug Kit (For overmolding)
1.05
Select this component from Table B
Panel Thickness Range = 0.063 to 0.250
Select this component from Table B
2.00
Select this component from Table B
Connector housings and backshells are illustrated in light gray with gray couplers. Standard color is black on black. *All dimensions shown in inches except where indicated
For additional information about this, or any other Amphenol Alden product, please contact
an Amphenol Alden specialist today.
Phone: 508-427-7000
Fax: 508-583-0164
www.amphenolalden.com
1
PL-900RG-N SERIES
Number of
Poles
52
41
35
28
24 (26AWG)
24 (22AWG)
17
15
11
9
Plastic
Shell Auto-Coupling Connectors
52 pole
capacity disposable receptacle and support interconnects
TABLE B:
Disposable Receptacle
Solder Cup
341406
341392
341378
341364
341350
341336
341322
341308
341294
341280
STANDARD PART NUMBERS
Rear Panel-Mount
Receptacle
Solder Cup
342512
342484
342456
342428
342541
342372
342344
342316
342288
342260
In-Line Plug
Solder Cup
341252
341224
341196
341168
341140
341112
341084
341056
341028
341000
PCB
342946
342932
342918
342904
342890
342876
342862
342848
342834
342820
PCB
342519
342491
342463
342435
342407
342379
342351
342323
342295
342267
Note: Part numbers cover black housings in Key 1 configuration. For other color and housing options utilize the Amphenol Alden connector configurator located at
www.amphenolalden.com/configurator
Options Include:
Indicator Color Options
Mating Key Options
Panel-Mount Thickness Options
Black (std.), Gray, White, Blue, Red, Green, Yellow
2 Standard Keys, Proprietary Keys Available
.125 (std.), .063, .187,.250
CONTACT TERMINATION OPTIONS
Termination Styles
Pin Length & Application
Pin Length & Applications
Panel 1
Flex Circuits Benefits
Facilitates the automated internal
application of passive and active
electronic components
Facilitates the introduction of
automated mass termination
techniques. These termination
methods are extremely cost
effective when terminating 52 pole
connectors
0.040
Intended for termination to flex circuit
Intended for mounting on rigid PC Board
Panel 2
PCB (Panel-Mount Receptacles only)
Features & Benefits
Available in most pole counts
PCB stand-offs ensure proper
Convenient packaging high
Request Sales Drawing for PCB
mounting template
positioning
temperature contect cures may
be soldered to PCB and snapped
into panel-mounted receptacle
housing later
from 9 to 52 Poles
Panel-Mount, Cut-Out Template
Features & Benefits
Tiered solder cups
provide easy access to
center positions. Canted
cups facilitate quick and
easy wire positioning.
Standard on 9-52 pole
configurations
.880φ
1.05
φ
mounting
Flange Footprint
.775
Applies to Rear Panel-Mount
Receptacles
Receptacles:
AI-PL900RGN-ILR01 (3Pole, 12AWG)
AI-PL900RGN-ILR02 (7Pole, 16AWG)
AI-PL900RGN-ILR03 (10-14Pole, 22AWG)
AI-PL900RGN-RPM01 (3Pole, 12AWG)
AI-PL900RGN-RPM02 (7Pole, 16AWG)
AI-PL900RGN-RPM03 (10-14Pole, 22AWG)
Plugs:
ASSEMBLY INSTRUCTIONS
AI-PL900RGN-P01 (3Pole, 12AWG)
AI-PL900RGN-P02 (7Pole, 16AWG)
AI-PL900RGN-P03 (10-14Pole, 22AWG)
For additional information about this, or any other Amphenol Alden product, please contact
an Amphenol Alden specialist today.
Phone: 508-427-7000
Fax: 508-583-0164
www.amphenolalden.com
2
PL-900RG-N SERIES
Backshell
Plastic
Shell Auto-Coupling Connectors
52 pole
capacity disposable receptacle and support interconnects
TABLE C:
(Wire exit i.d.)
A
Dimension A
0.140
0.166
0.180
0.210
0.260
Part Number
107307-01
107307-08
107307-15
107307-22
107307-29
ACCESSORIES
Disposable Receptacle Backshell:
In applications where the disposable receptacle is attached directly to
a cable or catheter this one piece backshell is available to protect
light gauge wire terminations and provide an anchor point for the
catheter jacket. These backshells snap into place and may be
encapsulated
Standard color is black. Gray is optional.
Protective Connective Caps (IP-67 Seal Rating)
Panel-Mount Receptacle Dust Cover
(Nylon Tether locks into panel washer)
Plug Soaking Cap
(Wire Tether with cable loop)
In-Line Receptacle Dust Cover
(Wire Tether with cable loop)
P/N
110401-01
Panel-Mount Receptacle Dust Cover:
The PL-900 Series receptacle dust
cover protects the receptacles contact
system from dust, moisture, and
mechanical stress when the connector
pair is disengaged. When secured the
dust cover will provide an IP-67
environmental seal. The cover is
equipped with a tether for security.
P/N
111179-01
P/N
111026-01
Plug Soaking Cap:
The PL-900 Series Plug Soaking Cap is
designed to protect the plug’s contact
system when a cable assembly is being
cleaned or not in use. The soaking cap
locks onto the plug providing an IP-67 seal
that is ideal for soaking lin liquid
disinfectants. The soaking cap can be
permanently attached to a a cable assembly
by means of a light weight tether.
Receptacle Dust Cover
(Without Wire Tether)
Plug Soaking Cap
(Without Wire Tether)
P/N
107522-01
P/N
107521-01
Note: Black (std.) Gray (opt.)
For additional information about this, or any other Amphenol Alden product, please contact
[b][size=10.5pt][b][color=#800080]LED[/color][/b]Term Notes[/size][/b]Radiant flux The energy emitted from a light source per unit time is called radiant flux Φ, and its unit is watt (W). Luminous flu...
[color=#000][font=宋体, Georgia, verdana, serif][size=12px]Learning to use a single-chip microcomputer is to understand the hardware structure of the single-chip microcomputer and the application of int...
I want to learn the key functions and display them on the digital tube. The display function is feasible, but why does it always display 8? #include
#include
#define uchar unsigned char #define uint u...
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
ISP devices, such as field programmable devices (FPGAs and CPLDs), do not require a programmer. Using programming kits provided by the device manufacturer, they employ a top-down modular design app...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
Electric motors and internal combustion engines of the same power have similar torque levels. High power requires high torque, and torque determines a vehicle's acceleration speed, commonly known a...[Details]
New energy pure electric vehicles generally accelerate faster than comparable fuel-powered vehicles, both from a standing start and while accelerating. Many believe this is simply due to the motor'...[Details]
In mobile technology, sensors are the primary input for measured signals and form a component of a sensor system. They include sensitive and transducer elements connected to carriers and circuits. ...[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
Laird Thermal Systems has introduced the HiTemp ET series Peltier cooler modules, which can operate at high temperatures and provide on-site cooling for sensitive electronic devices.
Dig...[Details]
1. Multi-channel DAC technology bottleneck
Currently,
the development of multi-channel DAC technology focuses on two core challenges.
First, industrial applications urgently ...[Details]
In daily life, power transformers have different functions and uses due to different usage scenarios. The most common ones can be divided into: control transformers, isolation transformers, rectifi...[Details]
Linear motor modules have become the "sweet spot" in various fields due to their advantages such as long stroke, fast speed, high precision, smooth operation and long life. Different models of line...[Details]
With the advancement of science and technology and the promotion of green, energy-saving, and circular development, the demand for precise control and accurate measurement is increasing. In the pow...[Details]
The composition of the water heater
The water heater itself is divided into the following parts:
1. Water tank.
This is where the water heater is filled with water and where the wate...[Details]
The mobile computing market is rapidly evolving, and manufacturers are fiercely competing for market share. A key area of competition is battery life, which encompasses two key aspects: how long th...[Details]
Lithium-ion batteries are a key component of electric vehicles. Their high energy density enables them to store a large amount of energy in a relatively compact and lightweight package, which is cr...[Details]