Circuit Breakers 489, 3P, DM, 480VAC/60VDC, D, 4A
CategoryCircuit protection   
File Size1MB,12 Pages
ManufacturerE-T-A Circuit Breakers
Environmental Compliance
Download Datasheet Parametric Compare View All

4230-T130-K0DU-4A Online Shopping

Suppliers Part Number Price MOQ In stock  
4230-T130-K0DU-4A - - View Buy Now

4230-T130-K0DU-4A Overview

Circuit Breakers 489, 3P, DM, 480VAC/60VDC, D, 4A

4230-T130-K0DU-4A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A Circuit Breakers
Product CategoryCircuit Breakers
RoHSDetails
Factory Pack Quantity1
Thermal-magnetic Miniature Circuit Breaker 4230-T...
Description
Single pole and multipole thermal-magnetic miniature circuit breakers
(MCBs) in accordance with EN 60947-2, UL 1077 and UL 489 for
DIN rail mounting, with toggle actuation, visual status indication and
high rupture capacity. A positively trip-free snap action mechanism
ensures reliable switching behaviour. A range of trip characteristics
and add-on modules allow a great variety of applications.
Typical applications
Protection of cables, motors, generators and transformers, thyristors
and silicon rectifiers. Protection of computers and their peripheral
equipment, industrial process control systems, telecommunications
equipment, power supplies.
UL 489 version
4230-T...
1
IEC/EN60947-2 & UL1077 version
Technical Data
Voltage rating and current rating range
to IEC/EN 60947-2
1-pole: AC 240 V; 1 A…63 A;
2, 3, 4-pole: AC 415 V, 1 A…63 A;
1-pole: DC 80 V, 1 A...63 A
2-pole: (2 poles connected in series)
DC 125 V, 1...63 A
1-pole: AC 277 V; 1 A…63 A;
2, 3, 4-pole: AC 480Y/277 V, 1 A…63 A;
1-pole: DC 60 V; 1 A...63 A;
2-pole (2 poles connected in series):
DC 125 V; 1 A...63 A;
1-pole: AC 120 V; 1A…63 A;
2, 3-pole: AC 240 V, 1 A…63 A;
1-pole: AC 277 V; 1 A…32 A;
2, 3-pole: AC 480Y/277 V; 1 A…32 A;
1-pole: DC 60 V; 1 A…63 A;
2-pole (2 poles connected in series);
DC 125 V; 1 A…63 A;
20,000 cycles
6,000 cycles
Technical Data
Rupture capacity
to IEC/EN 60947-2 (Ics)
to IEC/EN 60947-2
(Icu)
to UL 489
to UL1077
Number of
poles
1-pole
1-pole
2-, 3-,
4-pole
1-pole
2-pole in
series
Un
AC 240 V
AC 277 V
AC 480 V
DC 60 V
DC 125 V
In
AC 7,500 A / DC 10,000 A
AC/DC 10,000 A
AC/DC 10,000 A
TC
1
1
1
1
1
OL
1
0
1
0
0
SC
7.5 kA, U1
5 kA, U1
5 kA, U1
7.5 kA, U1
7.5 kA, U1
to UL 1077
to UL 489
1...63 A
1...63 A
1...63 A
1...63 A
1...63 A
Typical life
Mechanically
Electrically
Insulation coordination
Degree of protection
Vibration (sinusoidal)
test to IEC 60068-2-6,
test Fc
Shock, test to
IEC 60068-2-27, test Ea
Corrosion, test to IEC
60068-2-11, test Ka
Humidity, test to IEC
60068-2-78, test Cab
Terminals
6 kV/3 (reinforced insulation
at operating area)
IP20
± 0.38 mm (10–57 Hz), 5 g
(57–500 Hz)
10 frequency cycles per axis
30 g (11 ms)
96 hrs in 5% salt mist
48 hours at 95% RH,
temperature +40°C
screw terminals
Vertical connection possible
by means of busbars
2 Nm max.
≤35 mm²
-35°C...+ 70°C
rail mounting
approx. 116 g per pole (EN 60947-2/
UL 1077) approx. 131 g per pole
(UL 489)
Approvals
Approval
authority
TÜV
Standard
IEC/EN
60947-2
Rated voltage
AC 240/415 V
DC 80 V
DC 125 V
AC 480Y/277 V
DC 60 V
DC 125 V
AC 240 V
AC 480Y/277 V
DC 60 V
DC 125 V
Current ratings
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...32 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
UL
UL 1077 /
CSA-C22.2
No. 235
UL 489 /
CSA-C22.2
No. 5
UL
Tightening torque
Cable cross section
Ambient temperature:
Mounting
Mass
1638
www.e-t-a.de
1

4230-T130-K0DU-4A Related Products

4230-T130-K0DU-4A 4230-T130-K0DE-63A 4230-T120-K0DE-25A 4230-T130-K0BE-1.6A 4230-T110-K0DE-63A 4230-T120-K0DE-63A 4230-T110-K0CE-10A 4230-T130-K0CU-3A 4230-T110-K0DU-20A
Description Circuit Breakers 489, 3P, DM, 480VAC/60VDC, D, 4A Circuit Breakers 1077, 3P, DM, 480VAC/60VDC, D, 63A Circuit Breakers 1077, 2P, DM, 480VAC/60VDC, D, 25A Circuit Breakers 1077, 3P, DM, 480VAC/60VDC, B, 1.6A Circuit Breakers 1077, 1P, DM, 277VAC/60VDC, D, 63A Circuit Breakers 1077, 2P, DM, 480VAC/60VDC, D, 63A Circuit Breakers 1077, 1P, DM, 277VAC/60VDC, C, 10A Circuit Breakers 489, 3P, DM, 480VAC/60VDC, C, 3A Circuit Breakers 489, 1P, DM, 277VAC/60VDC, D, 20A
Product Attribute Attribute Value Attribute Value Attribute Value Attribute Value Attribute Value Attribute Value Attribute Value Attribute Value Attribute Value
Manufacturer E-T-A Circuit Breakers E-T-A Circuit Breakers E-T-A Circuit Breakers E-T-A Circuit Breakers E-T-A Circuit Breakers E-T-A Circuit Breakers E-T-A Circuit Breakers E-T-A Circuit Breakers E-T-A Circuit Breakers
Product Category Circuit Breakers Circuit Breakers Circuit Breakers Circuit Breakers Circuit Breakers Circuit Breakers Circuit Breakers Circuit Breakers Circuit Breakers
RoHS Details Details Details Details Details Details Details Details Details
Factory Pack Quantity 1 1 1 1 1 1 1 1 1

Recommended Resources

About the issue of sending and receiving MMS
Does anyone have any recommendations for Wavecom's GPRS module?...
albertzhou Embedded System
Has anyone studied pmon? Where to start looking at its source code?
As the title says, pmon is a mips structured bios....
maihy1985 Embedded System
About buying development boards in TI Mall
I bought a board on TI's official website last month, but the status has not changed. It has been more than 10 days, and I still haven't received the board. I remember it said it would arrive in 7 to ...
gameboy22 TI Technology Forum
Programming failure of new UPSD3254A device
I encountered this problem before when programming with the 8.22 version of express. When programming the new batch of upsd3254a with RLINK, it showed: Device ID is wrong! Later, I listened to the adv...
cailingli521 stm32/stm8
QQ group discussion -> forum discussion
Careful friends may find that some discussions come from our QQ cooperation group. I received a big surprise this morning, and I was so happy: Blue Sky says: “I found some issues discussed in the grou...
soso Talking
RFC2833 Negotiation process of dynamic payload class items of DTMF.
There are three ways to transmit DTMF: a. Transmit through communication protocols, such as H.323, MGCP, SIP, etc. b. Follow RFC2833 and use RTP packet header for transmission c. Transmit through RTP ...
lygtian Embedded System

Popular Articles

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2422  1325  784  765  2291  49  27  16  47  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号