EEWORLDEEWORLDEEWORLD

Part Number

Search

100-4P3-T1-B11-VS3-Q-E-HDW15

Description
Toggle Switch, 4PDT, Latched, 5A, 28VDC, Solder Terminal, Through Hole-straight
CategoryMechanical and electronic products    switch   
File Size2MB,10 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Environmental Compliance
Download Datasheet Parametric View All

100-4P3-T1-B11-VS3-Q-E-HDW15 Overview

Toggle Switch, 4PDT, Latched, 5A, 28VDC, Solder Terminal, Through Hole-straight

100-4P3-T1-B11-VS3-Q-E-HDW15 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Other featuresPANEL MOUNTABLE
Contact (AC) maximum rated R load5A@120VAC
Maximum contact current (AC)5 A
Maximum contact current (DC)5 A
Contact (DC) maximum rated R load5A@28VDC
Maximum contact voltage (AC)120 V
Maximum contact voltage (DC)28 V
Electrical life40000 Cycle(s)
JESD-609 codee4
Manufacturer's serial number100
Installation featuresTHROUGH HOLE-STRAIGHT
Maximum operating temperature85 °C
Minimum operating temperature-30 °C
sealEPOXY TERMINAL SEALED
surface mountNO
Switch actionLATCHED
switch function4PDT
Switch typeTOGGLE SWITCH
Terminal surfaceSilver (Ag)
Termination typeSOLDER
Base Number Matches1
SERIES 100 SWITCHES
TACT
SWITCHES
TOGGLE SWITCHES - MINIATURE
SPECIFICATIONS
NAVIGATION
SWITCHES
Contact Rating:
Life Expectancy:
Contact Resistance:
Insulation Resistance:
See contact material options
40,000 make-and-break cycles at full load
100 mΩ max. typical initial @ 2-4 VDC
100 mA for both silver and gold plated contacts
1,000 MΩ min.
1,000 V RMS @ sea level
PUSHBUTTON
SWITCHES
Dielectric Strength:
Operating Temperature: -30° C to 85° C
TOGGLE
SWITCHES
MATERIALS
Case:
Toggle Handle:
Switch Support:
Diallyl Phthalate (DAP)
Brass, chrome plated
Brass or steel, tin plated
Brass, nickel plated
Stainless steel
Silver or gold plated copper alloy
ROCKER
SWITCHES
FEATURES & BENEFITS
Up to 4 poles available
Variety of switching functions
Miniature
Multiple actuator & bushing options
APPLICATIONS/MARKETS
Telecommunications
Instrumentation
Networking
Medical equipment
Bushing:
Housing:
Contacts / Terminals:
SLIDE
SWITCHES
HOW TO ORDER
SERIES
MODEL NO.
ACTUATOR
BUSHING
TERMINATION
CONTACT
MATERIAL
SEAL
HARDWARE
SNAP-ACTION
SWITCHES
100
SP1
SP2*
SP3
SP4*
SP5*
DP1
DP2*
DP3
DP4*
DP5*
DP6
DP7*
DP8*
3P1
3P2*
3P3
3P4*
3P5*
4P1
4P2*
4P3
4P4*
4P5*
4P6
4P7*
4P8*
T1
T2
T3
T4
T5
T6
T7
T8
T9
K1
K2
Optional
E
B1
B2
B3
B4
B5
B6
B8
B9
B11
B12
B13
B15
B16
B25**
B26**
M1
M2
M3
M5
M6
M61
M7
M71
VS2
VS3
VS5*
M64*
VS21*
VS31*
Q = Silver
R = Gold
E = Epoxy
Sealed at
Base of
Terminal
H = Hardware
KEYLOCK
SWITCHES
DIP
SWITCHES
Toggle Cap
(T1 Only):
T100-1 = White
T100-2 = Black
DETECTOR
SWITCHES
ROTARY
SWITCHES
Example Ordering Number
100_ SP1_ T4_ B2_ M1_ R_ E
CAP
OPTIONS
Notes: * Not available with the K1 and K2
actuator options.
** Available only with the K1 and K2
actuator options.
Specifications subject to change without notice.
112
Phone: 800-867-2717
Fax: 763-531-8235
CE adds records to the database
I picked up a piece of code from a book, which is used to assign values to a new database record, but there is an error: bool CDataBaseTestDlg::AddNewStudent(REC_STUDENT stu) { CEOID ceOid; CEPROPVAL ...
ghmgs Embedded System
How to call another wince .exe from a wince program? ——Very difficult question!
Help: How to call another wince .exe from a wince program? --Urgent! Urgent!...
wanglq2005 Embedded System
Use CCS to connect to a running C2000 chip
1. IntroductionWhen the product is in the prototype testing stage, or when the product is put on the market, the program may occasionally run away or run abnormally. In many cases, such occasional fai...
fish001 Microcontroller MCU
XDS110-ET Onboard Emulator for MSP432
The MSP432 launchpad board has a switch S101 to control the selection of the onboard emulator XDS110-ET or the external emulator. The board has a J103 interface for debugging the homemade MSP432 board...
平湖秋月 Microcontroller MCU
Is the current from the inverter to the motor self-generated?
Because the inverter drives the motor, the motor output shaft heats up, and the temperature of the output shaft is much higher than the temperature of the shell. I asked the seniors on the forum, and ...
eeleader Industrial Control Electronics
Excellent courseware for "51 MCU Easy to Get Started - Based on STC15W4K Series"
[i=s]This post was last edited by Wuliangshoujing on 2016-2-20 16:12[/i] [size=3]"Easy to get started with 51 MCU - based on STC15W4K series" textbook supporting courseware. [/size][size=3][color=#ff0...
无量寿经 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 806  524  348  293  1258  17  11  8  6  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号