EEWORLDEEWORLDEEWORLD

Part Number

Search

CN202J31S115DQ8

Description
Double Pole Power Rocker Switches
File Size157KB,4 Pages
ManufacturerITT
Websitehttp://www.ittcannon.com/
Download Datasheet View All

CN202J31S115DQ8 Overview

Double Pole Power Rocker Switches

CN202J31S115DQ8 Preview

C&K CN Series
Double Pole Power Rocker Switches
Features/Benefits
Typical Applications
Illuminated versions available
Appliances
Multiple actuator and
Office equipment
termination styles
Computers and peripherals
Specifications
CONTACT RATING:
UL/CSA: 16 AMPS @ 125 VAC, 1/8 HP;
10 AMPS @ 250 VAC, 1/3 HP.
ELECTRICAL LIFE: 10,000 make and break cycles at full load.
INSULATION RESISTANCE: 108
min.
DIELECTRIC STRENGTH: 1,500 VRMS @ sea level.
Materials
HOUSING AND ACTUATOR: 6/6 nylon (UL94V-2), black, matte finish.
ILLUMINATED ACTUATOR: Polycarbonate, matte finish.
CENTER CONTACTS: Silver plated, copper alloy.
END CONTACTS: Silver plated AgSu02ln03.
ALL TERMINALS: Silver plated, copper alloy.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages 24 thru 26. For additional options not shown in catalog, consult Customer Service Center.
Switch Function
CN201
DPDT On-None-On
CN202
DPST On-None-Off
CN22
*
DPST On-None-Off
Actuator
J1
Rocker
J3
Illuminated rocker
J6
Rocker
J8
Illuminated rocker
Actuator Color
2
(STD). Black
1
White
3
Red
R
Red, illuminated
A
Amber, illuminated
G
Green, illuminated
Mounting Style/Color
S2
(STD.) Snap-in, black
S4
(STD.) Snap-in, black
S1
Snap-in, white
S3
Snap-in, white
Termination
15
(STD.) .187” quick connect
05
.250” quick connect
07
Solder lug
Actuator Marking
(NONE)
(STD.) No marking
D
ON-OFF
H
”O l” - international ON-OFF
P
”O -” international ON-OFF
Contact Rating
Q
(STD.) Silver (UL/CSA)
QA
Silver (UL/CSA with HP rating)
Lamp Rating
(NONE)
(STD.) No lamp
7
125 VAC neon
8
250 VAC neon
* CN22 - for switches with both marking and illumination
Dimensions are shown: Inch (mm)
Dimensions subject to change
24
www.ittcannon.com
C&K CN Series
Double Pole Power Rocker Switches
SWITCH FUNCTION
SWITCH FUNCTION
CONNECTED TERMINALS
NO.
POLES
MODEL NO.
C&K marking on opposite side
C&K marking on opposite side
SCHEMATIC
CN201
DP
ON
NONE
ON
2-3
N/A
2-1
OR
CN202
ON
NONE
OFF
For Illuminated
Version
CN22 *
ON
NONE
OFF
* CN22 - for switches with both marking and illumination
1b
2b
3b
ACTUATOR
J1
J3
ROCKER
ILLUMINATED ROCKER
J6
J8
ROCKER
ILLUMINATED ROCKER
NOTE:
J1 & J3 actuators available with Q contact rating only.
J3 actuator available with CN202 switch function only.
NOTE:
J6 & J8 actuators available with QA contact rating only.
J6 actuator available with CN201 & CN202 switch functions,
J8 actuator available with CN202 switch function only.
Dimensions are shown: Inch (mm)
Dimensions subject to change
25
www.ittcannon.com
C&K CN Series
Double Pole Power Rocker Switches
ACTUATOR COLOR
OPTION
CODE
ACTUATOR
COLOR
(STD.) BLACK
WHITE
RED
RED, ILLUMINATED
AMBER, ILLUMINATED
GREEN, ILLUMINATED
2
1
3
R
A
G
MOUNTING STYLE/COLOR
S2
S1
(STD.) SNAP-IN, BLACK
SNAP-IN, WHITE
S4
S3
(STD.) SNAP-IN, BLACK
SNAP-IN, WHITE
1b
2b
3b
1b
2b
3b
NOTE:
Available with 15 termination and Q contact rating only.
NOTE:
Available with 05 termination and QA contact rating only.
PANEL MOUNTING
PANEL THICKNESS
0.030-0.049 (0,75-1,25)
0.049-0.079 (1,25-2,0)
0.079-0.118 (2,0-3,0)
“X”
1.190-.004 (30,2-0,1)
1.197-.004 (30,4-0,1)
1.213-.004 (30,8-0,1)
“Y”
0.874+.004 (22,2+0,1)
0.874+.004 (22,2+0,1)
0.874+.004 (22,2+0,1)
TERMINATION
15
(STD.) .187” QUICK CONNECT
05
.250” QUICK CONNECT
1b
2b
3b
.102 DIA.
(ø2,6)
.413
(10,5)
.425
(1,8)
NOTE:
Available with S1 & S1 mounting style and Q contact rating only.
NOTE:
Available with S3 & S4 mounting styles and QA contact rating,
CN201 & CN202 switch functions only.
.250
(6,35)
Dimensions are shown: Inch (mm)
Dimensions subject to change
26
www.ittcannon.com
C&K CN Series
Double Pole Power Rocker Switches
TERMINATION
07
SOLDER LUG
.709
(18,0)
1.126
(28,6)
.031
(0,8)
.429
(10,9)
1.071
(27,2)
.250
(6,35)
.425
(1,8)
ACTUATOR MARKING
NONE
(STD.) NO MARKING
D
ON-OFF
H
Ol
P
O-
NOTE:
Orientation of actuator marking and terminals.
CONTACT MATERIAL
OPTION
CODE
CONTACT AND TERMINAL MATERIAL
SILVER
RATINGS
16 AMPS @ 125 VAC; 10 AMPS @ 250 VAC (UL/CSA)
16 AMPS @ 125 VAC, 1/8 HP @ 125 VAC;
10 AMPS @ 250 VAC, 1/3 HP @ 250 VAC (UL/CSA)
Q
(STD.)
QA*
* Not available with CN203, CN205 & CN207 switch functions.
LAMP RATING
(NONE)
NO LAMP
7
125 VAC 33kΩ NEON
8
250 VAC 150kΩ NEON
NOTE:
Lamp rating for J3 & J8 actuator options.
Dimensions are shown: Inch (mm)
Dimensions subject to change
27
www.ittcannon.com
1b
2b
3b
EEWORLD University Hall----Communication Electronic Circuits
Communication Electronic Circuits : https://training.eeworld.com.cn/course/5031This course mainly studies the working principle and composition of each unit of the transmitting and receiving equipment...
JFET Analog electronics
【Meet friends by disassembling】Teardown of TI's Bluetooth speaker
[i=s]This post was last edited by qwqwqw2088 on 2018-7-9 09:50[/i] [b][color=#5E7384]This content was originally created by EEWORLD forum netizen [size=3]qwqwqw2088[/size]. If you need to reprint or u...
qwqwqw2088 Making friends through disassembly
Notice of community adjustments during the National Day holiday from 13:00 on September 30 to 10:00 on October 8
Netizens:Hello! Thank you for your continued support! I wish you all a happy National Day!From 13:00 on September 30 to 10:00 on October 8, the community will make the following adjustments:1. Forum p...
okhxyyo Suggestions & Announcements
Can the MCV14A be programmed in C?
Just like the title says, I see my colleagues at work using MCV14A and they all write programs in assembly language, which means they don't know how to use assembly language....
hljjxzhla Microchip MCU
8259a related issues
I would like to ask if icw1-4 and ocw1-2 are written after the operating system initializes 8259a (of course, the corresponding modification depends on whether there is cascading). What should I do if...
franklin Embedded System
ADS4122IRGZT, have you tried it?
ADS4122IRGZT, have you tuned it? Do you have PCB layout experience? I don't know if this high-speed layout is possible in a single layer. Can an expert help me with a 65M 12-bit...
jsxykj1 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 85  2701  2469  844  2130  2  55  50  17  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号