Circuit Breakers 1077, 2p, DIN, 80VDC Med Delay, N/O Aux, 0.1A
CategoryCircuit protection   
File Size402KB,6 Pages
ManufacturerE-T-A Circuit Breakers
Environmental Compliance
Download Datasheet Parametric View All

8340-T120-K1M1-ALH126-0.1A Overview

Circuit Breakers 1077, 2p, DIN, 80VDC Med Delay, N/O Aux, 0.1A

8340-T120-K1M1-ALH126-0.1A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A Circuit Breakers
Product CategoryCircuit Breakers
RoHSDetails
Factory Pack Quantity1
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Description
Single, two and three pole magnetic and hydraulic-magnetic circuit
breakers with trip-free mechanism and toggle actuation. A choice of
fast magnetic only or hydraulically delayed switching characteristics
(S-type MO or HM CBE to EN 60934) ensures suitability for a wide
range of applications. Featuring a combi-foot design for symmetric rail
mounting. Low temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Power supplies, control equipment, communication systems, EDP
systems.
Standard current ratings and typical internal resistance values
Current
rating (A)
0,02
0,05
0,1
0,25
0,5
0,75
1
2
2,5
3
5
6
8
10
12
15
16
20
25
30
40
50
Internal resistance values (Ω) per pole
F1
1 493
276
58
8,2
2,3
0,98
0,58
0,145
0,096
0,065
0,025
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
953
152
37
6,0
1,47
0,63
0,35
0,096
0,061
0,048
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
F2
K1, M1, T1
2 669
452
100
15,5
3,9
1,65
0,95
0,26
0,15
0,10
0,042
0,029
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
K2, M2, T2
2 457
376
94
14,7
3,2
1,56
0,90
0,20
0,15
0,10
0,040
0,028
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
single pole
8340-T...
1
three pole
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415V; AC 240V (50/60Hz); DC 80V
(higher DC voltages to special order)
Current rating range
0.02...50 A DC
0.02...30 A AC
Auxiliary circuit
1 A, AC 240 V/DC 65 V; 0.5 A DC 80 V
Typical life
3 AC 415 V AC 240 V:
0.02...30 A 6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
WDC 80 V: 0.02...25 A 6,000 operations at 1 x I
N
, inductive
0.02...30 A 10,000 operations at 1 x I
N
, resistive
40 + 50 A 6,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A)
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit test voltage AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
I
N
0.02...20 A
25...30 A
(UL 1077)
AC:
1-pole AC 250 V/3,500A AC 250 V/3,500A
2-pole
3-pole
DC:
1-pole
2-pole
AC 250 V/3,500A
3AC 250V/3,500A
0.02...50 A
0.02...30 A
AC 250 V/5,000A
3AC250V/5,000A
DC 80 V/3,500 A
DC 80 V/3500 A
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
with curves F1, F2:
operating area IP40
terminal area IP20
10 g at 0.9 I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ± 0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
100 g (11 ms) at 0.8 x I
N
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 98 g per pole
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
1708
www.e-t-a.de
1
Who has the technical documentation for the 2011 National Race C smart car?
[i=s]This post was last edited by paulhyde on 2014-9-15 03:29[/i] Who has the relevant technical documents, program codes, modules, circuits, etc. for the 2011 National Race C smart car? If you have a...
melon_1 Electronics Design Contest
Request: DSP that supports USB2.0
Is there any dsp chip that supports usb2.0, preferably from TI (5509A only supports usb1.1, alas)...
sb576763418 Embedded System
How to Introduce White Noise in Circuit Simulation Software
I want to introduce white noise into the circuit and then check the simulation results. How do I add white noise? I tried TINA, a circuit simulation software, but it didn't work. I tried to generate w...
wstt Analog electronics
2 comparator circuits?
I thought the input and output of the circuit diagrams a and b should both be (A), but the actual answer is a corresponds to A and b corresponds to B. Don't understand?...
KG5 Analog electronics
Requesting a new version of RemoteDesktop for Windows CE 4.2
I have a PDA, Symbol PPT 8846 (8800 series) Windows CE 4.2. The built-in RemoteDesktop cannot go full screen, nor can it bring the sound to the PDA. I have installed some versions of RemoteDesktop, su...
zhaolequan Embedded System
Does anyone use Arca? Hope to exchange ideas
I recently came across the Ark Arca processor. I want to ask if any of you have experience with it? Hope we can communicate more!...
qigan Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2068  1851  2214  1393  392  42  38  45  29  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号