EEWORLDEEWORLDEEWORLD

Part Number

Search

8340-G221-K3F5-A4H0-30A

Description
Circuit Breakers
CategoryCircuit protection   
File Size317KB,6 Pages
ManufacturerE-T-A Circuit Breakers
Download Datasheet Parametric View All

8340-G221-K3F5-A4H0-30A Online Shopping

Suppliers Part Number Price MOQ In stock  
8340-G221-K3F5-A4H0-30A - - View Buy Now

8340-G221-K3F5-A4H0-30A Overview

Circuit Breakers

8340-G221-K3F5-A4H0-30A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A Circuit Breakers
Product CategoryCircuit Breakers
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Description
Single and two pole magnetic circuit breakers with trip-free
mechanism and push/pull on/off manual actuation. A choice of fast
magnetic only or hydraulically delayed switching characteristics (S-
type MO or HM CBE to EN 60934) ensures suitability for a wide range
of applications. Convenient threadneck panel or plug-in mounting,
and with a white push button indicator band showing clearly the
tripped/off position. Available with auxiliary contacts (1 x N/O, 1 x
N/C) for status signalling.
Approved to CBE standard EN 60934 (IEC 60934).
Typical application
Control equipment, communications systems, power semiconductors.
Standard current ratings and typical internal resistance values
Current rating (A)
Internal resistance (Ω) per pole
-F4/-F5
0.02
0.05
0.08
0.1
0.15
0.2
0.3
0.5
0.75
1
1.25
1.5
1.75
2
2.5
3
4
5
6
8
10
12
15
16
20
25
30
40
50
* 50 % ON duty / 60 min.
583
94
35.6
22.9
9.89
5.02
2.44
0.789
0.392
0.246
0.145
0.10
0.083
0.059
0.048
0.028
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02*
< 0.02*
-E1/H1/R1
2 896
531
202
129
57.3
30.5
13.9
4.50
2.19
1.10
0.695
0.487
0.355
0.295
0.174
0.121
0.0729
0.0437
0.0329
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
-E2/H2/R2
2 660
542
199
127
55.7
30.5
13.7
4.42
1.82
1.08
0.686
0.472
0.337
0.291
0.168
0.118
0.0687
0.0449
0.0323
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
1-pole
8340-G2...
1
2-pole
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V
(higher DC voltages to special order)
Current ratings
0.02...50 A DC
0.02...30 A AC
Auxiliary circuit
1 A, AC 240 V/DC 65 V
0.5 A, DC 80 V
Typical life
3 AC 415 V, AC 240 V:
0.02...30 A
6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
DC 80 V: 0.02...25 A
6,000 operations at 1 x I
N
, inductive
0.02...30 A
10,000 operations at 1 x I
N
, resistive
40 + 50 A
5,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit test voltage AC 1,500 V
switching to trip circuit test voltage AC 1,500 V
(version -X)
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
(UL 1077)
AC:
DC:
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with button down:
1-pole
2-pole
1-pole
2-pole
I
N
0.02...20 A
AC 250 V/3,500A
AC 250 V/3,500A
0.02...50 A
0.02...30 A
25...30 A
AC 250 V/3,500A
AC 250 V/5,000A
DC 80 V/3,500 A
DC 80 V/3500 A
operating area IP40
terminal area IP00
10 g (57-2000 Hz), ± 0.76 mm (10-57 Hz)
at 0.9 x I
N
other mounting planes: 10 g (57-2000 Hz) at I
N
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock
100 g (11 ms) at 1 x I
N
, directions 1,2,3,4,5
100 g (11 ms) at 0.8 x I
N
, direction 6
to IEC 60068-2-27, test Ea
Corrosion
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass
approx. 70 g per pole
1712
www.e-t-a.de
1
Use IAR to compile the program and connect it to the development board for program simulation
I encountered difficulties in the process of using IAR to develop MSP430 LaunchPad. Now I am in the primary learning stage. I don’t know how to use IAR to compile the program and connect it to the dev...
zhao_金辉 Microcontroller MCU
How can VC# smart device application use smart device ocx developed in vc2005? Expert advice
How can VC# smart device application use smart device ocx developed in vc2005? Expert advice...
llgg9527 Embedded System
How to draw rounded corner differential lines in AD?
It seems that the differential line can only be run at right angles and 45 degrees? Please guide...
sharbioue PCB Design
High-capacity power bank that can charge your phone 70 times
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:57[/i]   On the 8th, Japan's System-talks company launched a lithium-ion mobile power bank with a capacity of up to 75000mAh. It is exp...
sharley Mobile and portable
How do drivers make an application run?
How does a driver make an application run? I have seen a PDA where pressing a button would pop up a shutdown application interface. In general, it should be how the driver sends a message to the upper...
feeler Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 333  2511  2815  497  1947  7  51  57  10  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号