Technical Data Sheet
Cable assembly
RPC-3.50 PLUG – RTK 162 Cable – RPC-3.50 JACK
LU7-055-XXX
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
All dimensions are in mm; tolerances: ± 3mm for A
≤
300 mm; ± 1% for A > 300 mm
Available variants
Type
LU7-055-XXX
max. Insertion loss at 26.5 GHz
≤
0.00203 dB/mm * A mm + 0.40 dB
Weight (g) / pce
0.2456 g/mm * A mm + 190 g
XXX – length in mm = A
- Standard lengths are 600, 800 and 1000mm. The smallest possible length is 400mm. -
Assembly parts
Connector left
Connector right
Cable
Armour
RPC-3.50 plug
03S123-2U7S3
RPC-3.50 jack
03K123-2U7S3
RTK 162
Metal tubing with fixed bending rate and protection braid
Electrical data
Impedance
Frequency
Return loss
Insertion loss
Phase deviation:
After 90° bending
Straight after 3x90° bending
Amplitude stability
Return loss stability
Shielding Effectiveness
50
Ω
DC to 26.5 GHz
≥
26 dB, DC to 4 GHz
≥
20 dB, 4 GHz to 26.5 GHz
see table available variants
≤
1.0°, DC to 4 GHz
≤
3.0°, 4 GHz to 26.5 GHz
≤
0.5°, DC to 4 GHz
≤
1.5°, 4 GHz to 26.5 GHz
≤
0.03 dB, DC to 4 GHz
≤
0.05 dB, 4 GHz to 26.5 GHz
≥
48 dB, DC to 4 GHz
≥
40 dB, 4 GHz to 26.5 GHz
≥
100 dB up to 1 GHz
Individual testing and documentation:
Measurement plot with all 4 S-Parameters (S11; S22; S21; S12) is included with the cable assembly and on the
backside the care and handling instruction is printed.
RF_35/09.14/6.2
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
1/2
Technical Data Sheet
Cable assembly
RPC-3.50 PLUG – RTK 162 Cable – RPC-3.50 JACK
LU7-055-XXX
Mechanical data
Minimum bend radius:
60 mm
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Environmental data
Temperature range
RoHS
-40°C to +85°C
compliant
Packing
Standard
1 pce in box
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Martin Moder
Date
29.09.14
Approved
Herbert Babinger
Date
07.10.14
Rev.
f00
Engineering change number
14-s342
Name
Maik Knoll
Date
07.10.14
RF_35/09.14/6.2
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
2/2