BKAF3A234MAB40001F00

Description
FEMALE; MALE, MULTIWAY RACK AND PANEL CONN, CRIMP, PLUG; RECEPTACLE
Categorysemiconductor    Other integrated circuit (IC)   
File Size674KB,19 Pages
ManufacturerITT
Websitehttp://www.ittcannon.com/
Download Datasheet View All

BKAF3A234MAB40001F00 Overview

FEMALE; MALE, MULTIWAY RACK AND PANEL CONN, CRIMP, PLUG; RECEPTACLE

ARINC 600
Low insertion force contacts.
Both environmental and non- environmental
versions.
Polarizing posts that are removable from the
mating face.
Field replaceable inserts for size 22 and
power contacts.
Up to 800 size 22 contacts in one connector.
Crimp, coax, power, printed circuit and wire
wrappable post style contacts.
Uses standard DPX crimp, insertion/extraction
tooling.
Waveguide connections available.
BKAD/E/F
BKAD/E
Rear Release/Rear Removable
Size 12, 16, 20, 22 Crimp Contacts
BKAF
Front Release/Front Removable
Size 22 Solder Tail and Wrap Post Contacts
BKAD/E connectors represent a major milestones in
presenting a new rack and panel connector for
support of the air transportation market.
Several important design concerns have been ad-
dressed and solved in this new series. High mating
forces of pluggable modules in a rack have been
reduced by approximately two-thirds.
The low insertion force contacts are also inter-
changeable with the contacts used in the DPX
series and permit retrofit of existing equipment.
This new connector is totally intermateable and
intermountable with ARINC 600 connectors now in
the field.
The BKAF permits the user to easily replace a
contact in case of problems, rather than disas-
semble the entire connector--it is available with
size 22 contacts in wrap post or solder-tail ver-
sions. The system maintains the advantages of low
insertion force technology incorporated in all ARINC
600 connectors.
Pos-Aline Connector Construction Feature
In the ARINC 600 connector series, Size 22 con-
tacts are the only size that utilize this design
feature. The hooded socket extends from its in-
sulator while the pin contacts are shrouded by its
front insulator.
All other contacts used in this series employ stan-
dard contact design.
The result is that the complement of contacts for
the plug connectors will consist of pin contacts for
size 22 and socket contacts for all others. The
receptacle contacts will be just the reverse, socket
contact for size 22 and pin contacts for the
balance.
Material Specifications
BKAD
Material
Shell & Waveguide
Finish
Insulator
Material
Material
Contacts
Finish
Termination
Grommets/Seals
O-Ring
Material
Material
Aluminum alloy
Alodine
1200
Thermoset
Copper alloy
Gold over Nickel
Crimp
N/A
N/A
BKAE
Aluminum alloy
Alodine
1200
Thermoset
Copper alloy
Gold over Nickel
Crimp
Silicone-based Elastomer
Silicone-based Elastomer
BKAF
Aluminum alloy
Alodine
1200
Thermoset
Copper alloy
Gold over Nickel
P.C./Wrap Post
N/A
N/A
Specifications
QQ A-591/A380
MIL-C-5541
N/A
QQ-C-533
MIL-G-45204
N/A
N/A
N/A
Dimensions are shown in inches (millimeters).
Dimensions subject to change.
www.ittcannon.com
2
How to implement the anti-theft function and short message remote control shutdown function
When the system is just started, it automatically reads the SIM card information and compares it with the previous information. If there is a mismatch, the user is prompted to enter a password. If the...
red526 Embedded System
LED lights cannot be completely turned off
I am using a board with an ar9344 chip, which has 6 LED lights. Using the same method in Uboot, 5 lights can be turned off, but one light just becomes dim and cannot be turned off. What causes this ph...
Donnie.Song ARM Technology
May I ask how to connect the AD port to the 51 microcontroller?
This is a program I bought from Taobao, but I can't understand it myself, so please take up some of your time. The three pictures are the main program, and the other one is the schematic diagram....
electricor 51mcu
Questions about PWM waveform
The waveform has a dead zone. How to calculate the duty cycle of the output PWM waveform?I defined the dead zone in the program. The duty cycle without the dead zone is 34%, and the period is 50 micro...
somanyww Analogue and Mixed Signal
Please advise on the information exchange method between the driver and the MFC program
I know that the communication between MFC program and driver is carried out through DeviceIoControl function, but if the driver wants to return some information to MFC program, how to achieve it? Plea...
yucaic Embedded System
I want to transplant an interface to the board, similar to the mobile phone interface, what GUI should I use?
I want to make the LCD display a screen similar to a PDA interface after the board is powered on, and I can select items by pressing buttons. How can I do this? Can uC/Gui do this?...
flyingaway stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 465  86  2803  553  68  10  2  57  12  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号