54114251.151

Description
Mains Power Connector, 4A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The power connector   
File Size689KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

54114251.151 Overview

Mains Power Connector, 4A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT

54114251.151 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings4A, 250VAC
Manufacturer's serial number54
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Power Entry Modules with Line Filter
Felcom 54
www.schurter.com/pg06
Standard- or Medical-Filter
IEC Appliance Inlet C14 Modular Assembling Options
5411.XX5X.XXX
Appliance inlet
Fuseholder
Line filter
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
C14
70° C
F
70° C
- Panel Mount:
Snap-in version from front side
- 2 - 5 Functions:
Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fuse-
holder for fuse-links 5 x 20 mm 1- or 2-pole, Line filter in standard and
medical version
- Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
Description
Characteristics
- Modular component selection
- Individual components soldered on a printed circuit board
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Technical data of filter-components see blockfilter type 5500
- Fully insulated from the rear
- Qualified for use in equipment according IEC/EN 60950
Approvals
Other versions on request
References
Weblinks
- VDE Certificate Number: 101307
- UL File Number: E72928
- Line switch with other rocker marking
Alternative: version without line filter Felcom 64
pdf, General Product Information, Approvals, RoHS, CHINA-RoHS,
Mating Connectors, e-Store, SCHURTER-Stock-Check, Distributor-
Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.5
/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
F acc. to IEC/EN 60320-2-2,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
Standard Version, IEC 60939, IEC
60601-1, UL 1283, UL 544, EN 133
200, CSA C22.2 no. 8
Technical details
> 1'400'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
EMC Products

gprs module uses ppp protocol to negotiate return data analysis?
The following is the hexadecimal data returned after entering the AT+CGDATA=="PPP",1 command: 7E FF 7D 23 3F 7D 21 21 7D 23 7D 20 7D 39 7D 22 7D 26 7D 20 7D 2A 7D 20 7D 20 7D 27 7D 22 7D 28 7D 22 7D 2...
torresgerrard Embedded System
【Date with Spring】A short trip to Nanjing
Date with spring, date with beautiful women, party with brothers. All the way to Nanjing, there were car accidents and traffic jams on the highway.It was really tiring to travel around, but I was stil...
fengxin Talking
Participating in the HELPER2416 Development Board Student Aid Program - Summary of the First Week
It has been a week since I got the board. I have gained a lot this week:pleased:. Now I will make a summary: First of all, I have never been exposed to ARM before, so I started from scratch. When I go...
数码小叶 Embedded System
Ask ucos a small question? !
When I read many examples in books, they will add this sentence in the program of creating a new task: #if OS_CRITICAL_METHOD ==3 OS_CPU_SR cpu_sr #endif. It literally means if the interrupt method is...
h295472204 Real-time operating system RTOS
UCOS II program problem, #define __IO_REG32_BIT(NAME, ADDRESS,
#define __IO_REG32_BIT(NAME, ADDRESS, ATTRIBUTE, BIT_STRUCT)\ volatile __no_init ATTRIBUTE union \ { \ unsigned long NAME; \ BIT_STRUCT NAME ## _bit; \ } @ ADDRESS I don’t understand the program above...
racwin0 Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1973  149  2407  1355  319  40  3  49  28  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号