Mains Power Connector, 8A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The power connector   
File Size689KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

54238153.153 Overview

Mains Power Connector, 8A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT

54238153.153 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings8A, 250VAC
Manufacturer's serial number54
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Power Entry Modules with Line Filter
Felcom 54
www.schurter.com/pg06
Standard- or Medical-Filter
IEC Appliance Inlet C14 Modular Assembling Options
5411.XX5X.XXX
Appliance inlet
Fuseholder
Line filter
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
C14
70° C
F
70° C
- Panel Mount:
Snap-in version from front side
- 2 - 5 Functions:
Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fuse-
holder for fuse-links 5 x 20 mm 1- or 2-pole, Line filter in standard and
medical version
- Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
Description
Characteristics
- Modular component selection
- Individual components soldered on a printed circuit board
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Technical data of filter-components see blockfilter type 5500
- Fully insulated from the rear
- Qualified for use in equipment according IEC/EN 60950
Approvals
Other versions on request
References
Weblinks
- VDE Certificate Number: 101307
- UL File Number: E72928
- Line switch with other rocker marking
Alternative: version without line filter Felcom 64
pdf, General Product Information, Approvals, RoHS, CHINA-RoHS,
Mating Connectors, e-Store, SCHURTER-Stock-Check, Distributor-
Stock-Check, Accessories
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.5
/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
F acc. to IEC/EN 60320-2-2,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical details
Standard Version, IEC 60939, IEC
60601-1, UL 1283, UL 544, EN 133
200, CSA C22.2 no. 8
Technical details
> 1'400'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
EMC Products

Finally got one
I tried to click on it and found that I could still participate in the lottery if I didn’t win that time, so I tried it and won. I was so lucky. :loveliness::)...
shihuntaotie Talking
Share: Lightning strike experiment configuration, differential mode and common mode interference path analysis and design principles
Lightning strikes are a common physical phenomenon and the main source of voltage stress for power adapters. Improper protection can cause power damage or restart, thus affecting the normal operation ...
qwqwqw2088 Analogue and Mixed Signal
How to connect msp430g2553 with DAC0832
I'm working on a signal generator for g2553 recently, but after using DAC0832, I still can't get a waveform. The display module and the key module have been solved, but the most important waveform has...
苍之芒 Microcontroller MCU
Is there anyone here who does ce in Jiaxing, Zhejiang? I have a project and I want to find a friend to do it
The program running on the ce system is mainly used for communication with the communication background. The data packet format is available and the background has been developed. Now we need to devel...
myq412 Embedded System
The latest 2009 National Undergraduate Electronic Design Competition Topic Forecast Summary
[i=s]This post was last edited by paulhyde on 2014-9-15 09:44[/i] [align=center][align=center][b][size=3][font=宋体][color=blue]2009[/color][color=blue]National Undergraduate Electronic Design Competiti...
flomingo Electronics Design Contest
About 7SEG-MPX2-CC digital tube
Dear experts: When one side of the 7SEG-MPX2-CC displays a code, does the other side automatically display the opposite code? Is there any example to explain and analyze it? Thank you!...
jingdongbo Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 285  2437  2901  1944  2243  6  50  59  40  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号