MIL Series Connector, 41 Contact(s), Stainless Steel, Female, Crimp Terminal, Plug,
CategoryThe connector   
File Size242KB,6 Pages
ManufacturerSOURIAU
Environmental Compliance  
Download Datasheet Parametric View All

D38999/26KG41SDL Overview

MIL Series Connector, 41 Contact(s), Stainless Steel, Female, Crimp Terminal, Plug,

D38999/26KG41SDL Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSOURIAU
Reach Compliance Codecompliant
Is SamacsysN
Other featuresSTANDARD: MIL-DTL-38999, POLARIZED, RFI SHIELDED, COMPATIBLE CONTACT: M39029/56351
Back shell typeSOLID
Body/casing typePLUG
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Contact materialNOT SPECIFIED
Coupling typeTHREADED
DIN complianceNO
empty shellYES
Environmental characteristicsFLUID RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell materialSTAINLESS STEEL
Housing sizeG
Termination typeCRIMP
Total number of contacts41
Base Number Matches1

D38999/26KG41SDL Preview

8D - D38999 Stainless steel
MIL-DTL-38999 Serie
III
MIL-DTL-38999 Series
III
Stainless steel
33
8D - D38999 Stainless steel
Connector part numbers
Basic Series
Shell style:
0:
Square flange receptacle
1:
In line receptacle
7:
Jam nut receptacle
5:
Plug with RFI shielding.
Type:
-:
Connectors with standard crimp contacts.
L:
Receptacle with long spill (male and female size #22D, #20).
C:
Receptacle with short spill (male and female #22D, #20, #16).
S:
Receptacle with specific spill (male et female #22D)
W:
Receptacle with male contacts #22D for wire wrap (3 wraps)
T:
Receptacle with male contacts #20 for wire wrap (2 wraps)
Shell size:
09 - 11 - 13 - 15 - 17 - 19 - 21 - 23 - 25
Plating:
K:
Passivated
S:
Nickel
8D
0
-
11
K
35
P
N
**
Contact layout:
See page 8 to 11
Contact type:
P:
Pin
A:
Connector supplied less pin contact or with specific contacts (Connector marking: A+ orientation)
S:
Socket
B:
Connector supplied less socket contact or with specific contacts (Connector marking: B+ orientation)
Orientation:
N, A, B, C, D & E (See page 58)
Spécification:
046:
Tinned straight spills
251:
Connector provided with power contacts (layouts with contacts #8)
022:
Fuel tank
L:
For P or S contact type only, connectors delivered without contacts, connectors marking P or S plus orientation.
MIL-DTL 38999 part numbers*
Basic Series
Shell style:
20:
Square flange receptacle
24:
Jam nut receptacle
26:
Plug with RFI shielding.
Plating:
K:
Passivated
S:
Nickel
Shell size:
A - B - C - D - E - F - G - H - J
Contact layout:
See page 11 for layout according to MIL-DTL-38999
Contact type:
P:
Pin.
S:
Socket.
A:
Connector supplied less pin contact or with specific contacts (connector marking: A + orientation).
B:
Connector supplied less socket contact or with specific contacts (connector marking: B + orientation).
D38999 20
K
B
35
P
N
L
Orientation:
N, A, B, C, D & E (see page 58)
L:
For P or S contact type only, connector delevired without contacts, connector marking P or S (without L)
* Note:
To place an order of MIL connectors delivered without MIL removable crimp contacts and keep P or S plus orientation marking,
it must be specify clearly on the order (by adding a suffix L at the end of the P / N or specified in comment).
34
8D - D38999 Stainless steel
Dimensions
Receptacle type 0
Shell
size
09 (A)
11 (B)
13 (C)
15 (D)
17 (E)
19 (F)
21 (G)
23 (H)
25 (J)
A
Max.
20.90
20.90
20.90
20.90
20.90
20.90
20.10
20.10
20.10
B
Max.
10.60
10.60
10.60
10.60
10.60
10.60
11.40
11.40
11.40
C
Max.
2.50
2.50
2.50
2.50
2.50
2.50
3.20
3.20
3.20
D
thread
M12 x 1-6g
M15 x 1-6g
M18 x 1-6g
M22 x 1-6g
M25 x 1-6g
M28 x 1-6g
M31 x 1-6g
M34 x 1-6g
M37 x 1-6g
E
± 0,30
23.80
26.20
28.60
31.00
33.30
36.50
39.70
42.90
46.00
F
18.26
20.62
23.01
24.61
26.97
29.36
31.75
34.93
38.10
G
15.09
18.26
20.62
23.01
24.61
26.97
29.36
31.75
34.93
H
± 0,20
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.91
3.91
J
± 0,20
5.49
4.93
4.93
4.93
4.93
4.93
4.93
6.15
6.15
Dimensions in millimeters)
Receptacle type 7
Shell
size
09 (A)
11 (B)
13 (C)
15 (D)
17 (E)
19 (F)
21 (G)
23 (H)
25 (J)
A + 0.10
- 0.15
16.53
19.07
23.82
26.97
30.15
33.32
36.50
39.67
42.85
B
Max.
9.90
9.90
9.90
9.90
9.90
9.90
9.90
9.90
9.90
C
Max.
3.20
3.20
3.20
3.20
3.20
3.20
3.20
3.20
3.20
D
Max.
30.50
35.20
38.40
41.60
44.80
49.50
52.70
55.90
59.00
E
Max.
23.00
26.00
31.00
34.00
37.00
41.00
46.00
47.00
52.00
F
± 0.4
27.00
31.80
34.90
38.10
41.30
46.00
49.20
52.40
55.60
G
thread
M12 x 1-6g
M15 x 1-6g
M18 x 1-6g
M22 x 1-6g
M25 x 1-6g
M28 x 1-6g
M31 x 1-6g
M34 x 1-6g
M37 x 1-6g
Dimensions in millimeters
35
8D - D38999 Stainless steel
In line receptacle type 1
Shell
size
09 (A)
11 (B)
13 (C)
15 (D)
17 (E)
19 (F)
21 (G)
23 (H)
25 (J)
D
thread
M12 x 1-6g
M15 x 1-6g
M18 x 1-6g
M22 x 1-6g
M25 x 1-6g
M28 x 1-6g
M31 x 1-6g
M34 x 1-6g
M37 x 1-6g
ØF
15.90
19.05
22.25
25.40
30.15
31.75
34.75
37.10
41.30
Plug type 5
Shell
size
09 (A)
11 (B)
13 (C)
15 (D)
17 (E)
19 (F)
21 (G)
23 (H)
25 (J)
A
Max.
31.00
31.00
31.00
31.00
31.00
31.00
31.00
31.00
31.00
B
thread
M12 x 1-6g
M15 x 1-6g
M18 x 1-6g
M22 x 1-6g
M25 x 1-6g
M28 x 1-6g
M31 x 1-6g
M34 x 1-6g
M37 x 1-6g
C
Max.
21.80
25.00
29.40
32.50
35.70
38.50
41.70
44.90
48.00
Maximum coupling torque on panel for jam nut receptacle (type 7)
Shell
Coupling
torque
(N.m)
09
(A)
6
11
(B)
8
13
(C)
10
15
(D)
13
17
(E)
20
19
(F)
23
21
(G)
25
23
(H)
26
25
(J)
28
Mated connectors dimensions
Type 0 with plug
Type 7 with plug
Shell
size
09 (A)
11 (B)
13 (C)
15 (D)
17 (E)
19 (F)
21 (G)
23 (H)
25 (J)
A
Max.
37.00
37.00
37.00
37.00
37.00
37.00
36.00
36.00
36.00
B
Max.
52.30
52.30
52.30
52.30
52.30
52.30
51.30
51.30
51.30
C
Max.
38.30
38.30
38.50
38.50
38.50
38.50
38.50
38.50
38.50
D
Max.
53.60
53.60
53.80
53.80
53.80
53.80
53.80
53.80
53.80
Dimensions in millimeters
36
8D - D38999 Stainless steel
Receptacle with straight spill contacts
Shell size
Contact size
A
# 22D
# 22D
# 20
# 16
# 22D
# 22D
# 22D
# 22D
# 22D
# 22D
# 22D
# 22D
# 20
# 20
# 20
# 20
# 16
# 16
# 16
# 16
# 22D
# 22D
# 22D
# 20
# 16
# 22D
# 22D
# 22D
# 22D
# 22D
# 22D
# 22D
# 22D
# 20
# 20
# 20
# 20
# 16
# 16
# 16
# 16
Contact type
M&F
M&F
M&F
M&F
M
M
F
F
M
M
F
F
M
M
F
F
M
M
F
F
M&F
M&F
M&F
M&F
M&F
M
M
F
F
M
M
F
F
M
M
F
F
M
M
F
F
Spill type
L&C
S
C
C
L&C
L&C
L&C
L&C
S
S
S
S
C
C
C
C
C
C
C
C
L
C
S
C
C
L&C
L&C
L&C
L&C
S
S
S
S
C
C
C
C
C
C
C
C
L:
Long spill
09
(A)
11
(B)
13
(C)
15
(D)
17
(E)
0,70
0.50
0.70
1.15
19
(F)
21
(G)
23
(H)
25
(J)
L2
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
10.52
11.46
10.19
11.46
10.69
11.63
10.36
11.63
10.69
11.63
10.69
11.63
10.69
11.63
10.69
11.63
8.50
4.00
5.10
5.10
5.10
9.48
10.58
9.15
10.58
9.65
10.75
9.15
10.75
9.65
10.75
9.65
10.75
9.65
10.75
9.65
10.75
C :
Short spill
S:
Specific spill
10.34
11.28
10.01
11.28
10.51
11.45
10.18
11.45
10.51
11.45
10.51
11.45
10.51
11.45
10.51
11.45
L3
L4
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max.
9.59
10.69
9.26
10.69
9.76
10.86
9.26
10.86
9.76
10.86
9.76
10.86
9.76
10.86
9.76
10.86
M :
Male contact
Dimensions in millimeters
F:
Female contact
37
Network practice: Don't ignore DNS settings when establishing a domain controller
The domain controller is the core of the company's network management. Its failure often leads to the failure of the login of all users' computers in the network. However, when setting up the domain c...
xiaoxin RF/Wirelessly
About the system power supply reverse connection protection circuit
The simplest way to prevent reverse connection is to add a diode at the power supply to prevent reverse connection, but what type of diode should be selected? Should we choose a diode with a very stab...
ckx提问 Analog electronics
Weekly highlights: 2017.09.04~2017.09.10
[size=4]Good morning~ We meet again~ It's time for our wonderful review~ Come and see what good things there are in the past week~ [b][color=#ff0000]Recommended wonderful posts:[/color][/b] [url=home....
okhxyyo Energy Infrastructure?
How do you estimate the number of vias on the capacitors in the power supply section of a PCB? Do you need to drill a lot of vias if the capacitors don't carry a lot of current?
I usually calculate based on two 10*20 vias passing 1A current. But I don't understand why capacitors need to have so many holes in them to handle large currents? How to estimate the number of ground ...
普拉卡图 PCB Design
Will Renesas products be used?
We will use Renesas chips in 2013, but we have never used them before. I am worried that they will be the designated chips again this year. . ....
我塑我心 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1137  222  830  1971  2492  23  5  17  40  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号