SIT1602BI-21-30N-62.500000E Overview

-40 TO 85C, 3225, 20PPM, 3.0V, 6

SiT1602B
Low Power, Standard Frequency Oscillator
Features
Applications
52 standard frequencies between 3.57 MHz and 77.76 MHz
100% pin-to-pin drop-in replacement to quartz-based XO
Excellent total frequency stability as low as ±20 ppm
Operating temperature from -40°C to 85°C. For 125°C and/or
-55°C options, refer to
SiT1618, SiT8918, SiT8920
Low power consumption of 3.5 mA typical at 1.8V
Standby mode for longer battery life
Fast startup time of 5 ms
LVCMOS/HCMOS compatible output
Industry-standard packages: 2.0 x 1.6, 2.5 x 2.0, 3.2 x 2.5,
5.0 x 3.2, 7.0 x 5.0 mm x mm
Instant samples with
Time Machine II
and
Field Programmable
Oscillators
Ideal for DSC, DVC, DVR, IP CAM, Tablets, e-Books,
SSD, GPON, EPON, etc
Ideal for high-speed serial protocols such as: USB,
SATA, SAS, Firewire, 100M / 1G / 10G Ethernet, etc.
RoHS and REACH compliant, Pb-free, Halogen-free and
Antimony-free
For AEC-Q100 oscillators, refer to
SiT8924
and
SiT8925
Electrical Characteristics
All Min and Max limits are specified over temperature and rated operating voltage with 15 pF output load unless otherwise
stated. Typical values are at 25°C and nominal supply voltage.
Table 1. Electrical Characteristics
Parameters
Output Frequency Range
Symbol
f
Min.
Typ.
Max.
Unit
Condition
Refer to
Table 13
for the exact list of supported frequencies
Frequency Range
52 standard frequencies between
MHz
3.57 MHz and 77.76 MHz
-20
-25
-50
-20
-40
1.62
2.25
2.52
2.7
2.97
2.25
45
90%
Frequency Stability
F_stab
Frequency Stability and Aging
+20
ppm
Inclusive of initial tolerance at 25°C, 1st year aging at 25°C,
and variations over operating temperature, rated power
+25
ppm
supply voltage and load.
+50
ppm
Operating Temperature Range
+70
°C
Extended Commercial
+85
°C
Industrial
Supply Voltage and Current Consumption
1.8
1.98
V
Contact
SiTime
for 1.5V support
2.5
2.75
V
2.8
3.08
V
3.0
3.3
V
3.3
3.63
V
3.63
V
3.8
4.5
mA
No load condition, f = 20 MHz, Vdd = 2.8V to 3.3V
3.7
4.2
mA
No load condition, f = 20 MHz, Vdd = 2.5V
3.5
4.1
mA
No load condition, f = 20 MHz, Vdd = 1.8V
4.2
mA
Vdd = 2.5V to 3.3V, OE = GND, Output in high-Z state
4.0
mA
Vdd = 1.8 V. OE = GND, Output in high-Z state
2.6
4.3
ST = GND, Vdd = 2.8V to 3.3V, Output is weakly pulled down
̅ ̅̅
A
1.4
2.5
ST = GND, Vdd = 2.5V, Output is weakly pulled down
̅ ̅̅
A
0.6
1.3
ST = GND, Vdd = 1.8V, Output is weakly pulled down
̅ ̅̅
A
LVCMOS Output Characteristics
1
1.3
55
2
2.5
2
%
ns
ns
ns
Vdd
All Vdds. See Duty Cycle definition in
Figure 3
and
Footnote 6
Vdd = 2.5V, 2.8V, 3.0V or 3.3V, 20% - 80%
Vdd =1.8V, 20% - 80%
Vdd = 2.25V - 3.63V, 20% - 80%
IOH = -4 mA (Vdd = 3.0V or 3.3V)
IOH = -3 mA (Vdd = 2.8V and Vdd = 2.5V)
IOH = -2 mA (Vdd = 1.8V)
IOL = 4 mA (Vdd = 3.0V or 3.3V)
IOL = 3 mA (Vdd = 2.8V and Vdd = 2.5V)
IOL = 2 mA (Vdd = 1.8V)
Operating Temperature Range
T_use
Supply Voltage
Vdd
Current Consumption
Idd
OE Disable Current
Standby Current
I_OD
I_std
Duty Cycle
Rise/Fall Time
DC
Tr, Tf
Output High Voltage
VOH
Output Low Voltage
VOL
10%
Vdd
Rev 1.04
January 30, 2018
www.sitime.com
PB5.0 error when exporting SDK
An error occurred when exporting SDK from PB5.0. Please help me. When exporting SDK from PB5.0, the following error occurred. Can an expert give me a pulse and see where the problem lies? I have just ...
zuigui111 Embedded System
Zigbee protocol stack learning serial port transparent transmission experiment (SerialApp) process analysis
The first function: networking of the coordinator, terminal devices and routing devices discovering the network and joining the network //Step 1: Z-Stack starts with the main() function. The main() fu...
wateras1 RF/Wirelessly
EEWORLD University ---- Power supply design tips 1: Choose the correct operating frequency for your power supply
Power Design Tip 1: Choose the right operating frequency for your power supply : https://training.eeworld.com.cn/course/504...
dongcuipin Power technology
STM32 FSMC connected to LCD routine: How does MCU determine the register address of the external LCD controller?
Keil4's built-in demo: STM32F103VE uses FSMC to drive LCD AM-240320L8TNQW00H (ILI9320), MCU's A0 is connected to LCD's RS, and in lcd.c there is: typedef struct { __IO uint16_t LCD_REG; __IO uint16_t ...
illino stm32/stm8
The emulator can be connected, but when burning the flash, an error message like this will be generated
**** Begin Sector Clear Operation **** OK: Flash Algorithm loaded into DSP memory OK: Write sector value 0x000f to symbol PRG_options OK: Set Breakpoint at PRG_stop OK: Running flash algorithm OK: DSP...
liuchenbaidu Microcontroller MCU
Problems with conversion of different line widths in AD
I have set different line widths. When I automatically route, the GND line is 20mil and the signal line is 10mil according to my rules. But when I manually connect the GND port, there is no change and...
44444444444444 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1220  122  2888  1443  2106  25  3  59  30  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号