EEWORLDEEWORLDEEWORLD

Part Number

Search

K3HB-PNB 24VAC/VDC

Description
COUNTER LCD 5 CHAR 24V PANEL MT
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size2MB,16 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance
Download Datasheet Parametric Compare View All

K3HB-PNB 24VAC/VDC Overview

COUNTER LCD 5 CHAR 24V PANEL MT

K3HB-PNB 24VAC/VDC Parametric

Parameter NameAttribute value
typeprocess timer
Operating modesuperior
counting rate50kHz
Time format-
Number of characters per line5,5
display typeLCD - dual color characters, backlit
Display characters - height0.560"(14.20mm),0.192"(4.90mm)
input typeNo voltage, voltage
Output typeOption cards available
Voltage - Power24VAC/DC
resetexternal
Panel opening sizeRectangular - 92.00mm x 45.00mm
Installation typePanel mounting
Terminal typescrew terminal
Intrusion protectionIP66 - dust and water resistant
Operating temperature-10°C ~ 55°C
weight0.662 lbs (300.28g)
Timer Interval Indicator
K3HB-P
CSM_K3HB-P_DS_E_15_2
Digital Time Interval Meter for Measuring
Passing Speed, Time, or Cycle between Two
Points.
• Visual confirmation of judgement results through display colors that
switch between red and green.
*1
• Measures Wide Range of Pulse Interval Times
Measures, calculates, and displays pulse intervals between two points. Wide
range for pulse interval measurements, from 10 ms to 3,200 s, max.
• Six Measurement Operations, Including Passing Speed, Time, and
Cycle Measurement between Two Points
One Digital Time Interval Meter has six measurement functions, to support a
variety of pulse interval measurement applications. Select the best function
for your application from the following: Passing speed, cycle, time difference,
time band, measuring length, and interval.
• DeviceNet models added to the series.
*2
*1
Visual confirmation of judgement results is not supported on models that do not have an
output or models that do not support DeviceNet.
You can change the display color by setting it, but you cannot switch it based on the judgement results.
*2
DeviceNet models have a depth of 97 mm.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Refer to
Safety Precautions for All Digital Panel
Meters.
Model Number Structure
Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units
K3HB-P
@
1
5
1. Input Sensor Code
NB: NPN input/voltage pulse input
PB: PNP input
5. Supply Voltage
100-240 VAC: 100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC
Base Units with Optional Boards
K3HB-P@-@@@
1
2 3 4
5
2. Sensor Power Supply/Output Type Code
None: None
CPA: Relay output (PASS: SPDT) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 1.)
L1A:
Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
L2A:
Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
A:
Sensor power supply (12 VDC ±10%, 80 mA)
FLK1A: Communications (RS-232C) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
FLK3A: Communications (RS-485) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
Note: 1.
CPA can be combined with relay outputs only.
2.
Only one of the following can be used by each Digital Indicator: RS-232C/RS-
485 communications, a linear output, or DeviceNet communications.
3. Relay/Transistor Output Type Code
None: None
C1:
Relay contact (H/L: SPDT each)
C2:
Relay contact (HH/H/LL/L: SPST-NO each)
T1:
Transistor (NPN open collector: HH/H/PASS/L/LL)
T2:
Transistor (PNP open collector: HH/H/PASS/L/LL)
BCD∗: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)
DRT: DeviceNet (See note 2.)
A Special BCD Output Cable (sold separately) is required.
4. Event Input Type Code
None: None
1:
5 inputs (HOLD/RESET), NPN open collector
2:
8 inputs (HOLD/RESET/BANK1/BANK2/BANK4), NPN open collector
3:
5 inputs (HOLD/RESET), PNP open collector
4:
8 inputs (HOLD/RESET/BANK1/BANK2/BANK4), PNP open collector
Optional Board
Sensor Power Supply/Output Boards
K33-@
2
Relay/Transistor Output Boards
K34-@
3
Event Input Boards
K35-@
4
Note:
The following combinations are not possible.
• Communications (FLK@A) + DeviceNet (DRT)
• Communications (FLK@A) + BCD output (BCD)
• Linear current/voltage (L@A) + DeviceNet (DRT)
1

K3HB-PNB 24VAC/VDC Related Products

K3HB-PNB 24VAC/VDC K3HB-PPB 100-240VAC K3HB-PPB 24VAC/VDC
Description COUNTER LCD 5 CHAR 24V PANEL MT COUNTER LCD 5 CHAR 100-240V PNL COUNTER LCD 5 CHAR 24V PANEL MT
type process timer process timer process timer
Operating mode superior superior superior
counting rate 50kHz 50kHz 50kHz
Number of characters per line 5,5 5,5 5,5
display type LCD - dual color characters, backlit LCD - dual color characters, backlit LCD - dual color characters, backlit
Display characters - height 0.560"(14.20mm),0.192"(4.90mm) 0.560"(14.20mm),0.192"(4.90mm) 0.560"(14.20mm),0.192"(4.90mm)
input type No voltage, voltage No voltage No voltage
Output type Option cards available Option cards available Option cards available
Voltage - Power 24VAC/DC 100 ~ 240VAC 24VAC/DC
reset external external external
Panel opening size Rectangular - 92.00mm x 45.00mm Rectangular - 92.00mm x 45.00mm Rectangular - 92.00mm x 45.00mm
Installation type Panel mounting Panel mounting Panel mounting
Terminal type screw terminal screw terminal screw terminal
Intrusion protection IP66 - dust and water resistant IP66 - dust and water resistant IP66 - dust and water resistant
Operating temperature -10°C ~ 55°C -10°C ~ 55°C -10°C ~ 55°C
weight 0.662 lbs (300.28g) 0.662 lbs (300.28g) 0.662 lbs (300.28g)
MSP430G2553 embedded with UCOS2 operating system
Can MSP430G2553 be directly implanted with this operating system? Do I need to expand the memory space? Can anyone with experience tell me the points to note when implanting 430 or give me some good s...
278023330 Microcontroller MCU
Standing wave protection circuit
The transistors in most solid-state amplifiers will fail to work in a mismatched state, and the dissipation is relatively large. In the worst case, the tube will be burned out when the mismatch is ser...
啊小罗 RF/Wirelessly
Why does my infrared receiver always output high level regardless of whether there is infrared light or not?
Why when I use the integrated infrared receiver, the level is always high regardless of whether there is infrared light or not? Why is that?...
Sherlock_Z Analog electronics
matlab
[i=s] This post was last edited by paulhyde on 2014-9-15 02:58 [/i] matlab...
799879197 Electronics Design Contest
How to protect the CAN bus from lightning?
In a broad sense, lightning protection includes two concepts, one is lightning protection and the other is surge protection. Lightning strike is the phenomenon of instantaneous release of electric cha...
qwqwqw2088 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1494  390  2779  2884  1427  31  8  56  59  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号