EEWORLDEEWORLDEEWORLD

Part Number

Search
 PDF

TEQ 160-7215WIR

Description
DC/DC CONVERTER 24V 180W
CategoryPower/power management   
File Size387KB,4 Pages
ManufacturerTraco Power
Websitehttps://www.tracopower.com/
Environmental Compliance
Download Datasheet Parametric Compare View All

TEQ 160-7215WIR Overview

DC/DC CONVERTER 24V 180W

TEQ 160-7215WIR Parametric

Parameter NameAttribute value
typeclosed
Voltage - Input (minimum)43V
Voltage - input (maximum)160V
Number of outputs1
Voltage - Output 124V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)7.5A
Power (W)180W
Voltage - Isolation2.25kV
applicationHazardous Locations, ITE (Commercial), Railway
efficiency89%
Operating temperature-40°C ~ 105°C
Installation typeBase installation
size/dimensions4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm)
ApprovalCB,cULus,cURus

TEQ 160-7215WIR Related Products

TEQ 160-7215WIR TEQ 160-7212WIR TEQ 160-7216WIR TEQ 160-7218WIR TEQ 160-4812WIR TEQ 160-4815WIR TEQ 160-4816WIR TEQ 160-4818WIR
Description DC/DC CONVERTER 24V 180W DC/DC CONVERTER 12V 180W DC/DC CONVERTER 28V 182W DC/DC CONVERTER 48V 182W DC/DC CONVERTER 12V 156W DC/DC CONVERTER 24V 156W DC/DC CONVERTER 28V 154W DC/DC CONVERTER 48V 154W
type closed closed closed closed closed closed closed closed
Voltage - Input (minimum) 43V 43V 43V 43V 19V 19V 19V 19V
Voltage - input (maximum) 160V 160V 160V 160V 75V 75V 75V 75V
Number of outputs 1 1 1 1 1 1 1 1
Voltage - Output 1 24V 12V 28V 48V 12V 24V 28V 48V
Current - Output (maximum) 7.5A 15A 6.5A 3.8A 13A 6.5A 5.5A 3.2A
Power (W) 180W 180W 182W 182W 156W 156W 154W 154W
Voltage - Isolation 2.25kV 2.25kV 2.25kV 2.25kV 2.25kV 2.25kV 2.25kV 2.25kV
application Hazardous Locations, ITE (Commercial), Railway Hazardous Locations, ITE (Commercial), Railway Hazardous Locations, ITE (Commercial), Railway Hazardous Locations, ITE (Commercial), Railway Hazardous Locations, ITE (Commercial), Railway Hazardous Locations, ITE (Commercial), Railway Hazardous Locations, ITE (Commercial), Railway Hazardous Locations, ITE (Commercial), Railway
efficiency 89% 89% 89% 89% 90% 90% 90% 90%
Operating temperature -40°C ~ 105°C -40°C ~ 105°C -40°C ~ 105°C -40°C ~ 105°C -40°C ~ 105°C -40°C ~ 105°C -40°C ~ 105°C -40°C ~ 105°C
Installation type Base installation Base installation Base installation Base installation Base installation Base installation Base installation Base installation
size/dimensions 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm) 4.06" long x 3.50" wide x 3.45" high (103.1mm x 88.9mm x 87.6mm)
Approval CB,cULus,cURus CB,cULus,cURus CB,cULus,cURus CB,cULus,cURus CB,cULus,cURus CB,cULus,cURus CB,cULus,cURus CB,cULus,cURus
Design of luminous signboard circuit
Please advise how to proceed...
柯小西 PCB Design
LM3S MCU_JTAG port unlocking notes
[i=s]This post was last edited by paulhyde on 2014-9-15 03:36[/i]...
逆风飞翔 Electronics Design Contest
Getting Started
[align=left][font=宋体]The hardware was introduced earlier. This article introduces the initial steps. [/font][/align][align=left][font=宋体]First, based on the needs of this project, only the core board ...
cz0842 MEMS sensors
How to debug serial port program on a computer without serial port connection?
I heard some people say that opening two serial port debugging software is enough, but it doesn't work? Do I need to connect a serial port device?...
honguan Embedded System
Local pointer variables conflict with global variables
The sprintf function is called in a sub-function, and the pointer variable *s is defined to access the formatted ASCII code of an integer variable:char *s;sprintf(s,"%-6u",a);but after I simulated it,...
zllka Microcontroller MCU
Is there anyone who is familiar with WIN XPe development? Please help me develop it.
We have developed a CNC system for equipment, which uses an industrial computer + DSP structure. The original design of the host computer was done in C++ under WIN XP. Now we hope to change it to an e...
帐单 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1050  2518  828  55  2772  22  51  17  2  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号