EEWORLDEEWORLDEEWORLD

Part Number

Search

4230-T130-K0BE-5A

Description
CIR BRK THERM-M 5A 480VAC/125VDC
CategoryCircuit protection   
File Size1MB,12 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Download Datasheet Parametric View All

4230-T130-K0BE-5A Online Shopping

Suppliers Part Number Price MOQ In stock  
4230-T130-K0BE-5A - - View Buy Now

4230-T130-K0BE-5A Overview

CIR BRK THERM-M 5A 480VAC/125VDC

4230-T130-K0BE-5A Parametric

Parameter NameAttribute value
Circuit breaker typeThermomagnetic
Rated current5A
Rated voltage - AC480V
Rated voltage - DC125V
Number of poles3
Actuator typepress slice
illuminationnone
Lighting voltage (nominal)-
Installation typeDIN rail
Thermal-magnetic Miniature Circuit Breaker 4230-T...
Description
Single pole and multipole thermal-magnetic miniature circuit breakers
(MCBs) in accordance with EN 60947-2, UL 1077 and UL 489 for
DIN rail mounting, with toggle actuation, visual status indication and
high rupture capacity. A positively trip-free snap action mechanism
ensures reliable switching behaviour. A range of trip characteristics
and add-on modules allow a great variety of applications.
Typical applications
Protection of cables, motors, generators and transformers, thyristors
and silicon rectifiers. Protection of computers and their peripheral
equipment, industrial process control systems, telecommunications
equipment, power supplies.
UL 489 version
4230-T...
1
IEC/EN60947-2 & UL1077 version
Technical Data
Voltage rating and current rating range
to IEC/EN 60947-2
1-pole: AC 240 V; 1 A…63 A;
2, 3, 4-pole: AC 415 V, 1 A…63 A;
1-pole: DC 80 V, 1 A...63 A
2-pole: (2 poles connected in series)
DC 125 V, 1...63 A
1-pole: AC 277 V; 1 A…63 A;
2, 3, 4-pole: AC 480Y/277 V, 1 A…63 A;
1-pole: DC 60 V; 1 A...63 A;
2-pole (2 poles connected in series):
DC 125 V; 1 A...63 A;
1-pole: AC 120 V; 1A…63 A;
2, 3-pole: AC 240 V, 1 A…63 A;
1-pole: AC 277 V; 1 A…32 A;
2, 3-pole: AC 480Y/277 V; 1 A…32 A;
1-pole: DC 60 V; 1 A…63 A;
2-pole (2 poles connected in series);
DC 125 V; 1 A…63 A;
20,000 cycles
6,000 cycles
Technical Data
Rupture capacity
to IEC/EN 60947-2 (Ics)
to IEC/EN 60947-2
(Icu)
to UL 489
to UL1077
Number of
poles
1-pole
1-pole
2-, 3-,
4-pole
1-pole
2-pole in
series
Un
AC 240 V
AC 277 V
AC 480 V
DC 60 V
DC 125 V
In
AC 7,500 A / DC 10,000 A
AC/DC 10,000 A
AC/DC 10,000 A
TC
1
1
1
1
1
OL
1
0
1
0
0
SC
7.5 kA, U1
5 kA, U1
5 kA, U1
7.5 kA, U1
7.5 kA, U1
to UL 1077
to UL 489
1...63 A
1...63 A
1...63 A
1...63 A
1...63 A
Typical life
Mechanically
Electrically
Insulation coordination
Degree of protection
Vibration (sinusoidal)
test to IEC 60068-2-6,
test Fc
Shock, test to
IEC 60068-2-27, test Ea
Corrosion, test to IEC
60068-2-11, test Ka
Humidity, test to IEC
60068-2-78, test Cab
Terminals
6 kV/3 (reinforced insulation
at operating area)
IP20
± 0.38 mm (10–57 Hz), 5 g
(57–500 Hz)
10 frequency cycles per axis
30 g (11 ms)
96 hrs in 5% salt mist
48 hours at 95% RH,
temperature +40°C
screw terminals
Vertical connection possible
by means of busbars
2 Nm max.
≤35 mm²
-35°C...+ 70°C
rail mounting
approx. 116 g per pole (EN 60947-2/
UL 1077) approx. 131 g per pole
(UL 489)
Approvals
Approval
authority
TÜV
Standard
IEC/EN
60947-2
Rated voltage
AC 240/415 V
DC 80 V
DC 125 V
AC 480Y/277 V
DC 60 V
DC 125 V
AC 240 V
AC 480Y/277 V
DC 60 V
DC 125 V
Current ratings
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...32 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
UL
UL 1077 /
CSA-C22.2
No. 235
UL 489 /
CSA-C22.2
No. 5
UL
Tightening torque
Cable cross section
Ambient temperature:
Mounting
Mass
1638
www.e-t-a.de
1
The simplest sensor circuit diagram
The simplest sensor circuit needs to be plugged into the serial port of the PC to use, using the powerful functions of the computer for various applications. Its interface circuits have their own stre...
fish001 Analogue and Mixed Signal
LM3S6911 serial port 1 can enter interrupt, but serial port 2 cannot? Is there something else to set for serial port 2? ?
I am experimenting with LM3S6911 serial port 1 and serial port 2. Serial port 1 can enter the interrupt, but serial port 2 cannot. I changed all USART1 in the program to USART2, enabled the correspond...
caoqing Microcontroller MCU
Simulation software selection
Dear experts, I want to use software to simulate the discrete device Mosfet circuit. I don't know if there is any software that can correspond to the actual device when selecting the device, or whethe...
solitary Discrete Device
EMI Control in Real-World Printed Circuit Board Design (First Six Chapters)
If you want to learn, you can read the first half....
hexinzhou PCB Design
μC/OS-II Reference Manual
μC/OS-II Reference Manual (English version)...
sssls2008 Embedded System
Drive circuit
Use DSP to generate PWM waveform (two complementary waveforms), use a boost circuit to drive KD301. As a result, the voltage of the waveform is completely pulled down as soon as it is connected. KD301...
doc Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1603  859  353  218  453  33  18  8  5  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号