EEWORLDEEWORLDEEWORLD

Part Number

Search

8340-F110-P1T1-A0H0-20A

Description
CIR BRKR MAG 20A 240VAC 80VDC
CategoryCircuit protection   
File Size455KB,6 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Environmental Compliance
Download Datasheet Parametric View All

8340-F110-P1T1-A0H0-20A Online Shopping

Suppliers Part Number Price MOQ In stock  
8340-F110-P1T1-A0H0-20A - - View Buy Now

8340-F110-P1T1-A0H0-20A Overview

CIR BRKR MAG 20A 240VAC 80VDC

8340-F110-P1T1-A0H0-20A Parametric

Parameter NameAttribute value
Circuit breaker typeMagnetic
Rated current20A
Rated voltage - AC240V
Rated voltage - DC80V
Number of poles1
Actuator typepress slice
illumination-
Lighting voltage (nominal)-
Installation typePanel mounting
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description
Single and multipole magnetic circuit breakers with trip-free
mechanism and toggle actuation. A choice of fast magnetic only or
hydraulically delayed switching characteristics (S-type MO or HM
CBE to EN 60934) ensures suitability for a wide range of applications.
Industry standard dimensions and panel mounting. Options include
auxiliary changeover contacts. Low temperature sensitivity at rated
load.
Approved to CBE standard EN 60934 (IEC 60934).
Typical application
Control equipment, communications systems, transportation, power
supplies.
1-pole
8340-F...
1
2-pole
Standard current ratings and typical internal resistance values
Current
rating (A)
0,02
0,05
0,1
0,25
0,5
0,75
1
2
2,5
3
5
6
8
10
12
15
16
20
25
30
40
50
Internal resistance values (Ω) per pole
F1
1 493
276
58
8,2
2,3
0,98
0,58
0,145
0,096
0,065
0,025
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
953
152
37
6,0
1,47
0,63
0,35
0,096
0,061
0,048
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
F2
K1, M1, T1
2 669
452
100
15,5
3,9
1,65
0,95
0,26
0,15
0,10
0,042
0,029
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
K2, M2, T2
2 457
376
94
14,7
3,2
1,56
0,90
0,20
0,15
0,10
0,040
0,028
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V
(higher DC ratings to special order)
Current ratings
0.02...50 A DC
0.02...30 A AC
Auxiliary circuit
6 A, AC 240 V;
3 A, DC 28 V
1 A, DC 65 V;
0.5 A, DC 80 V
Typical life
3 AC 415 V, AC 240 V:
0.02...30 A
6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
DC 80 V: 0.02...25 A
6,000 operations at 1 x I
N
, inductive
0.02...30 A
10,000 operations at 1 x I
N
, resistive
40 + 50 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit
test voltage AC 3,000 V
switching to trip circuit
test voltage AC 1,500 V
(version -X)
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
(UL 1077)
AC:
1-pole
2-pole
3-pole
1-pole
2-pole
I
N
0.02...20 A
25...30 A
AC 250 V/3,500A AC 250 V/3,500A
AC 250 V/3,500A AC 250 V/5,000A
3AC 250V/3,500A 3AC250V/5,000A
0.02...50 A
0.02...30 A
DC 80 V/3,500 A
DC 80 V/3500 A
DC:
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
Shock
Corrosion
Humidity
Mass
1747
www.e-t-a.de
operating area IP40
terminal area IP00
10 g (57-2000Hz) ± 0.76 mm (10-57 Hz)
at 0.9 x IN
10 g (57-2000 Hz) at 1 x IN.
100 g (11 ms) at 1 x IN, directions 1,2,3,4,5
100 g (11 ms) at 0.8 x IN, direction 6.
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 65 g per pole
1
[ZigBee Information] ZigBee Learning Guide
This software is based on Microchip's MpZBee1.0 source code, with a lot of prompt information, which is convenient for users to observe and learn the details of the software operation process, data fo...
Hugo801122 RF/Wirelessly
After ADC is started, DMA or converted values cannot be used
I want to use AD to start, and after the conversion is completed, DMA will transfer the converted value directly to the array without entering an interrupt, and the debugging has not been successful! ...
ZhengLang Microcontroller MCU
Can sensorless drive completely replace sensory drive?
When selecting BLDC driver chips, I see that many new ones are sensorless. Can this type of sensorless type completely replace sensor-based chips? What are the advantages and disadvantages of each typ...
littleshrimp Motor Drive Control(Motor Control)
Motor drive development communication 3: Software component description
Continue from the previous post: https://bbs.eeworld.com.cn/thread-1155646-1-1.htmlDescription of the software part:In addition to writing and debugging their own software, software engineers are also...
安驱技术_孙大卫 Motor Drive Control(Motor Control)
Looking for accommodation using mps-430 2553
1~5V sine wave signal acquisition and display, 1602 display, maximum and minimum values, average value, 128 points required, 50Hz sine signal, help, ADC, I don't know how to use it...
kokoko110 Microcontroller MCU
Is there any expert or kind person who can contribute an IFS2003
Can any expert or kind person contribute a copy of IFS2003? Thank you very much!...
ssky Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2349  1120  1941  1295  1270  48  23  40  27  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号