50W Single Output DC-DC Converter
■
‧
SD-50
series
Ultra Compact Modbus Gateways
Models MESP211D, MESP211T
‧
‧
‧
‧
www.advantech-bb.com
‧
‧
‧
‧
PRODUCT FEATURES
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
SD-50A-5
5V
10A
0 ~ 10A
50W
4.5 ~ 5.5VDC
±0.5%
SD-50B-5
•
SD-50C-5
•
•
•
•
Modbus TCP Ethernet, Modbus ASCII & RTU RS-232/422/485
Modbus
SD-50B-12 SD-50C-12 SD-50A-24 SD-50B-24
SD-50A-12
Flexibility – Serial & Ethernet, Masters & Slaves
View Messaging Status in Real Time
24V
12V
Ultra
4.2A
Compact IP30 Metal Enclosure
2.1A
International Power Supply (included
0 ~ 2.1A
0 ~ 4.2A
50.4W
120mVp-p
11 ~ 16VDC
±1.0%
±0.3%
50.4W
150mVp-p
23 ~ 30VDC
±1.0%
±0.2%
SD-50C-24
RIPPLE & NOISE (max.)
Note.2
100mVp-p
VOLTAGE TOLERANCE
Note.3
±2.0%
™
Models MESP211D and MESP211T, Vlinx series Modbus Gateways, connect
LOAD REGULATION
±0.5%
±0.3%
±0.2%
ORDERING INFORMATION
Modbus devices to Ethernet networks and let you monitor
------ at full load
SERIAL
SETUP, RISE, HOLD UP TIME
2.5s, 50ms,
and control Modbus
MODEL NUMBER PROTOCOL
PORT
devices from anywhere on the Ethernet LAN or WAN.
18VDC
Supporting
B:19 ~
16
up to
36VDC
VOLTAGE RANGE
A:9.2 ~
C:36 ~ 72VDC
MESP211D
RS-232/422/485 DB9 Male
masters and 32 slaves, these gateways feature an auto-detecting 10/100
76%
EFFICIENCY (Typ.)
70%
73%
72%
75%
78%
74%
INPUT
MESP211T
RS-232/422/485 Removable
Ethernet copper RJ-45 port and a serial port that supports RS-232/422/485
Terminal Block
7A/12V
3A/24V
1.5A/48V
7A/12V
3A/24V
1.5A/48V
7A/12V
DC CURRENT
communications via a DB9 male or a terminal
105 ~ 150% rated output power
block connection.
ETHERNET
PORT
1
80%
1
3A/24V
ETHERNET
CONNECTOR
RJ45
83%
RJ45
1.5A/48V
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
is built for use in industrial environments with a heavy-duty metal
The product
5.75 ~ 6.75V/10% load
16.8 ~ 20V/10% load
31.5 ~ 37.5V/10% load
ACCESSORIES
OVER VOLTAGE
enclosure that is panel (standard) or DIN rail mountable (with optional adapters).
Protection type : Hiccup mode, recovers automatically after fault condition
Supply, 12 VDC 6 Watt, 5MM Plug, International AC Input,
SMI6-12-V-P5 -
Included Power
is removed
The product can be supplied with a DC power source ranging from 10 to 30
-10 ~ +60℃ (Refer to "Derating Curve")
International AC Blades
WORKING TEMP.
VDC and features a barrel connector. A power supply is included.
DRAD35
- Optional DIN rail adapter clip (pair)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
Ease of Use
TEMP. COEFFICIENT
±0.03%/℃
(0 ~ 50℃)
Configuration, upgrades and monitoring of the serial server are simple, easy
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
tasks with Vlinx Manager Software. It installs on your PC giving access to
Design refer to LVD
SAFETY STANDARDS
the serial server via your desktop. Remotely manage the Modbus Gateway
I/P-O/P:1.5KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
SAFETY & WITHSTAND VOLTAGE
over a LAN or WAN via the build-in web server. This is helpful for off-site
ISOLATION RESISTANCE
I/P-O/P,
EMC
troubleshooting and can be done with an ordinary web
I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
browser.
(Note 4)
EMC EMISSION
Compliance to EN55032 (CISPR32) Class B
ENVIRONMENT STORAGE TEMP., HUMIDITY
-20 ~ +85℃, 10 ~ 95% RH
232NM9
- Optional mull modem crossover cable
EMC
Compliance to EN61000-4-2,3,4,6,8, EN55024, heavy industry level, criteria A
Software Support
IMMUNITY
MTBF
365.6K hrs min.(SD-50A)
357.5K hrs min.(SD-50B)
368.5K Hrs min.(SD-50C)
Windows XP (32/64 bit), 2003 Server (32/64 bit), Vista 32/64 bit), 2008 Server
OTHERS
DIMENSION
(32/64 bit), Windows 7 (32/64 bit), Windows 8
159*97*38mm (L*W*H)
10 (32/64
(32/64 bit), Windows
0.48Kg; 24pcs/12.7Kg/0.75CUFT
PACKING
bit).
NOTE
MIL-HDBK-217F (25℃)
℃
All product specifications are subject to change without notice.
File Name:SD-50-SPEC 2017-07-14
MESP211D & MESP211T_3617ds
orders@advantech-bb.com
support@advantech-bb.com
Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
50W Single Output DC-DC Converter
Mechanical Specification
152.5
Ultra Compact Modbus Gateways
SD-50
Case No. 901
series
Unit:mm
Models MESP211D, MESP211T
1
9.5
2
3
4
8.2
5
65
3.5
7
www.advantech-bb.com
84.5
2-M
3
PRODUCT FEATURES
ψ
3
.5
4.5
24
78
159
6.5
9
150
•
•
•
•
•
Modbus TCP Ethernet, Modbus ASCII & RTU RS-232/422/485
Modbus Flexibility – Serial & Ethernet, Masters & Slaves
View Messaging Status in Real Time
Ultra Compact IP30 Metal Enclosure
International Power Supply (included
97
18.5
Terminal Pin No. Assignment
Pin No.
1
ORDERING INFORMATION
2
MODEL NUMBER PROTOCOL
3
3.5
28.5
38
9
3-
Models MESP211D and MESP211T, Vlinx
™
series Modbus Gateways, connect
M3
Modbus devices to Ethernet networks and let you monitor and control Modbus
devices from anywhere on the Ethernet LAN or WAN. Supporting up to 16
22
masters and 32 slaves, these gateways feature an
117
auto-detecting 10/100
Ethernet copper RJ-45 port and a serial port that supports RS-232/422/485
communications via a DB9 male or a terminal block connection.
MESP211D
MESP211T
RS-232/422/485
Assignment
DC INPUT V+
DC
SERIAL
INPUT V-
PORT
FG
Pin No.
Assignment
4
DC OUTPUT -V
5
ETHERNET ETHERNET
DC OUTPUT +V
18
Block Diagram
The product is built for use in industrial environments with a heavy-duty metal
fosc : 83KHz
ACCESSORIES
enclosure that is panel (standard) or DIN rail mountable (with optional adapters).
SMI6-12-V-P5 -
Included Power Supply, 12 VDC 6 Watt, 5MM Plug, International AC Input,
The product can be supplied with a DC power source ranging from 10 to 30
POWER
International AC
RECTIFIERS
EMI
+V
Blades
I/P
&
FILTER
SWITCHING
-V
VDC and features a barrel connector. A power supply is included.
DIN rail
DRAD35
- Optional
FILTER
adapter clip (pair)
Ease of Use
Configuration, upgrades
FG
monitoring of the serial server are simple, easy
and
tasks with Vlinx Manager Software. It installs on your PC giving access to
PWM
O.L.P.
CONTROL
the serial server via your desktop. Remotely manage the Modbus Gateway
over a LAN or WAN via the build-in web server. This is helpful for off-site
troubleshooting and can be done with an ordinary web browser.
232NM9
- Optional mull modem crossover cable
DETECTION
CIRCUIT
O.V.P.
Derating Curve
Software Support
Windows XP (32/64 bit), 2003 Server (32/64 bit), Vista 32/64 bit), 2008 Server
(32/64 bit), Windows 7 (32/64 bit), Windows 8 (32/64 bit), Windows 10 (32/64
SD-50B,C
100
bit).
80
28
300
250
200
150
100
50
24
20
16
12
8
60
SD-50A
40
20
-10
-10
0
0
10
20
30
40
50
45
60
55
(VERTICAL)
(HORIZONTAL)
25
30
35
40
45
50
55
60
65
70
72
AMBIENT TEMPERATURE (℃)
INPUT VOLTAGE (V)
All product specifications are subject to change without notice.
File Name:SD-50-SPEC 2017-07-14
MESP211D & MESP211T_3617ds
orders@advantech-bb.com
support@advantech-bb.com
Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
OUTPUT RIPPLE (mVp-p)
OUTPUT VOLTAGE (V)
ψ
3.5
RS-232/422/485
DB9 Male
Removable
Terminal Block
PORT
1
CONNECTOR
RJ45
1
RJ45
Static Characteristics(SD-50C-24V)
32
350
LOAD (%)