EEWORLDEEWORLDEEWORLD

Part Number

Search

3G3MV-P10CDT3-E

Description
INVERTER PLC OPTION ADV TYPE
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size105KB,5 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance
Download Datasheet Parametric Compare View All

3G3MV-P10CDT3-E Online Shopping

Suppliers Part Number Price MOQ In stock  
3G3MV-P10CDT3-E - - View Buy Now

3G3MV-P10CDT3-E Overview

INVERTER PLC OPTION ADV TYPE

3G3MV-P10CDT3-E Parametric

Parameter NameAttribute value
type-
Motor type-
Control/drive type-
Voltage - Load-
Current - Output-
Voltage - Power-
interface-
Installation type-
Operating temperature-
characteristic-
Supporting products/related products-
weight-
3G3MV
Inverters
Inverters
3G3MV
Versatile Compact Inverter Offers Loop
Vector and V/Hz Control
• Intuitive digital operator controls all parameter selections
and settings
• Quick Start LEDs for fast setup and troubleshooting
• Standard PID control
• Modbus serial communications standard
• DeviceNet communications unit (optional) allows remote
monitoring of Run/Stop status and operating conditions, and
making changes to set values
• Fine-tune speed using the potentiometer on the digital
operator
• User-selectable open loop vector and V/Hz control methods
• NEMA 4X models meet requirements for tough washdown
and dust-tight environments
• NEMA 1 models available
• Compact size: Single phase, 230 VAC: 148 H x 170 W x
180 D mm max.
• Three-phase, 230 VAC: 260 H x 180 W x 170 D mm max.
• Three-phase, 460 VAC: 260 H x 180 W x 170 D mm max.
• Integrate a full-featured PLC into 3G3MV inverters with
6 input/4 output points, encoder input, interrupt inputs and
pulse outputs; dual port RAM for 200 transfers per second;
eliminates point-to-point wiring
A032
Specifications
General Specifications
Power supply
Rated input voltage & frequency 3-phase, 200 to 230 V, 50/60 Hz
Single-phase, 200 to 240 V, 50/60 Hz
Allowable voltage fluctuation
Allowable frequency fluctuation
Control characteristics
Control method
Frequency control range
Frequency accuracy
(temperature change)
Frequency setting resolution
Output frequency resolution
Overload capacity
Frequency setting signal
Accel/Decel
Braking torque
Sine wave PWM (V/f control or voltage vector control, selectable);
possible to program any V/f pattern
0.1 to 400 Hz
Digital reference: ±0.01%, 14 to 122°F (-10 to +50°C)
Analog reference: ±0.5%, 59 to 95°F (25±10°C)
Digital reference: 0.1 Hz (less than 100 Hz)/0.1 Hz (100 Hz or more)
Analog reference: (0:06/60 Hz) equivalent to 1/1000 of max. output frequency
0.01 Hz
150% rated output current for one minute
0 to 10 VDC (20 kΩ), 4 to 20 mA (250
Ω),
0 to 20 mA (250
Ω)
pulse train input, frequency setting potentiometer
(Selectable)
0.01 to 6000 seconds (accel/decel time are independently programmed 2 types)
Short-term average deceleration torque:
0.1, 0.25 kW (0.13 HP, 0.25 HP): 150%; 0.55, 1.1 kW): (0.5 HP, 1 HP): 100% 1.5 kW (2 HP): 50%; 2.2 kW (3 HP)
or more: 20%
Continuous regenerative torque: Approx. 20% (150% with optional braking resistor, braking transistor built-in)
-15% to +10%
±5%
3-phase, 380 to 460 V, 50/60 Hz
I-18
For complete specifications and additional models:
U.S.
www.omron.com/oei
Canada
www.omron.ca

3G3MV-P10CDT3-E Related Products

3G3MV-P10CDT3-E 3G3IV-PEZZ08122D 3G3MV-P10CDT-E
Description INVERTER PLC OPTION ADV TYPE bracket din rail mounting INVERTER PLC OPTION STD TYPE
Quartus II setup problem
has two settings that I don't know how to fix. Because I couldn't restore them after the previous operation? ? ? (1) How can I changeback to the original ? I have been looking for this setting for a l...
wengzf FPGA/CPLD
ucos critical protection problem
I would like to ask for advice onOS_ENTER_CRITICAL() andOS_EXIT_CRITICAL()If uCos-II is running multiple tasks, and the highest priority task writes some global variables (such as assignment or additi...
greedangel Real-time operating system RTOS
Looking for operational amplifier video learning materials
I am not familiar with op amps. Although I feel that I understand the theory, I just feel that I don't have the practical skills. Therefore, I want to find some video materials about op amps. I would ...
yhye2world Discrete Device
The host computer written in MFC receives UDP packets via Ethernet. Why can't it read the data in the buffer?
I used LM3S8962 to write a program to send UDP messages using Ethernet. It can correctly receive UDP messages from the host computer and can also send UDP messages. The messages sent by LM3S8962 can b...
huangzhechen Microcontroller MCU
Newbies learning STM8 help
I studied electronics in college, and I have been working for 2 years. I have done other things. Now I am back to study. The nature of my job is to do research and development. I use STM8 microcontrol...
wiln stm32/stm8
Manage wireless communication process
In a typical wireless communication system, when the electric energy starts, it is the current signal flowing along the conductor. The transmitter modulates the electric information source with high-f...
nich20xx RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 81  60  1363  1570  650  2  28  32  14  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号