ClassⅡ 42W LED Controlgear : PA-1400-46 Series
Product Features
• Universal AC Input
• High Power Factor
• Low Total Harmonic Distortion
• Short Circuit / Open Circuit / Over Voltage / Over Temperature Protections
• Suitable for Dry & Damp Location
• Adjustable Output Current by Dimming Input
• RoHS Compliant
AC Input / DC Output
• AC Input Voltage
• AC Input Frequency
• Max. Input Current @ 110Vac (60Hz)
• Min. PF @ 230Vac (50Hz) / 60V Output
• Min. PF @ 230Vac (50Hz) / 42V Output (70% load)
• Min. PF @ 277Vac (60Hz) / Output > 25W
• Max. THD @ 110~277Vac / Output > 25W
• Min. Eff. @ 220Vac / 60V Output
• Turn On Delay Time
• DC Output Current
• Line Regulation
• Load Regulation
• DC Output Voltage Range
• Ripple Current
• DC Output Isolation
100 ~ 305Vac (110 ~ 277Vac)
47 ~ 63Hz (50~60Hz)
0.6A
0.95
0.92
0.9
20%
86%
<1.5 seconds
700mA
±3%
±5%
28 ~ 60V
±20%
yes
EMC
• EMI
• Harmonic Current Emissions
• Voltage Fluctuations & Flicker
• Electrostatic Discharge (ESD)
• RS Immunity Test
• Electrical Fast Transient
• Lighting Surge
• CS Immunity Test
• Voltage Dips & Short Interruptions
FCC Class A
EN61000-3-2
EN61000-3-3
EN61000-4-2
±4KV (Contact),±8KV (Air)
EN61000-4-3
80MHz ~ 1GHz, 3V/m, 80% AM (1KHz)
EN61000-4-4
±1KV for AC power line, ±0.5KV for DC / signal line
EN61000-4-5
±4KV (Com.), ±4KV (Dif.), test time interval : 35s
EN61000-4-6
0.15MHz ~ 80MHZ, 3V, 80% AM (1KHz)
EN61000-4-11
30%, 25 cycles voltage reduction
100%, 0.5 cycles voltage reduction
Operating Environments / Reliability
• Operating Temperature / Humidity
• Storage Temperature / Humidity
• Vibration (with shipping container)
• Vibration (operation)
• MTBF Life (Note 3)
• Tc
• Cooling
• Sound Level
-40 ~ 60℃ / 10 ~ 95% RH
-40 ~ 80℃ / 10 ~ 95% RH
1.146Grms / 5~200Hz / six sides
30 minutes / side
6Grms / 10~1000Hz / X/Y/Z axis
15 minutes / axis
50,000 Hrs while Tc≦75℃
100,000 Hrs while Tc≦65
℃
85℃
free air convection
meet Class A sound rating
Mechanical
• AC Input Terminal
• DC Output Terminal
• Dimming Input Terminal
• Weight (typ.)
• Outline Dimension
170mm / black(L) & white(N) color / UL1316
170mm / red(DC +) & blue(DC -) color / UL1316
170mm / purple(dim +) & gray(dim -) color / UL1316
550g
159.2mm(L) * 57.2mm(W) * 32mm(H)
Protections
• OVP or Open Circuit
• SCP
• OTP
constant voltage, 79V max.
auto recovery
output power decrease
Safety / Certifications
• Hi Pot (AC I/P to Case)
3750Vac / 10mA / 60Sec.
• Hi Pot (AC I/P to O/P)
3750Vac / 10mA / 60Sec.
• Insulation (AC I/P to O/P)
>20MΩ
, 500Vdc
• Complied with UL8750, 1st Edition
• Complied with UL60950-1, 2nd Edition
• Complied with CSA C22.2
• Complied with IEC 61347-2-13:2006
• Complied with IEC 61347-1(Second Edition):2007+A1:2010
• Complied with IEC 62384:2006(1 Edition)
Dimming Input
• Support 2 in 1 Dimming Function
• Resistor Dimming Range (10~100K)
• Voltage Dimming Range (1~10V)
• Resistor Dimming Reference Table
Resistor Dimming
75KΩ
±1%
Output Current
540mA
±10%
Tolerance
• Voltage Dimming Reference Table
Voltage Dimming
7.7V
Output Current
540mA
±10%
Tolerance
48.7KΩ
±1%
350mA
±10%
5V
355mA
±10%
Notes :
(1) above definition is based on 25℃ ambient if not specified
(2) this LED driver is designed and intended for operating with LED load only
(3) MTBF evaluation is based on SR-332 method, 115Vac/60Hz, max load
(4) to measure efficiency after burn-in 30 minutes with full output load
(5) recommend to install the controlgear inside the enclosure
Revised on 2015.03.25
(SL) Ver. C
www.liteon.com
ClassⅡ 42W LED Controlgear : PA-1400-46 Series
Performance Curves
• Power Factor (PF / Output Power)
PF
1.00
0.99
0.98
0.97
0.96
0.95
0.94
0.93
0.92
0.91
0.90
• THD (THD / Output Power)
THD
PF
THD
14.00%
12.00%
10.00%
120Vac
240Vac
8.00%
6.00%
4.00%
2.00%
0.00%
120Vac
240Vac
277Vac
277Vac
Output Power(%)
Output Power(%)
• Efficiency (Eff. / Output Power)
Eff.
90.00%
89.00%
88.00%
87.00%
86.00%
85.00%
84.00%
83.00%
82.00%
• Output Current Tolerance (Tolerance / Output Power)
Tolerance
5.00%
3.00%
1.00%
120Vac
120Vac
Efficiency
Output Current Tolerance
240Vac
277Vac
-1.00%
-3.00%
-5.00%
240Vac
277Vac
Output Power(%)
Output Power(%)
• PF>0.9 & THD<20% Operating Range (120Vac/60Hz Input)
• PF>0.9 & THD<20% Operating Range (240Vac/50Hz Input)
PF>0.9、THD<20% Operating Range
70
65
60
55
50
45
40
35
30
25
20
100
110mA
60V
PF>0.9、THD<20% Operating Range
70
65
60
55
50
45
40
35
30
25
20
Output Voltage (V)
160mA
60V
Output Voltage (V)
700mA
60V
700mA
60V
220mA
28V
700mA
28V
343mA
28V
700mA
28V
200
300
400
500
600
700
100
200
300
400
500
600
700
Input:120Vac/60Hz
Output Current (mA)
Input :240V
AC
/50Hz
Output Current (mA)
• PF>0.9 & THD<20% Operating Range (277Vac/60Hz Input)
70
65
60
55
50
45
40
35
30
25
20
PF>0.9、THD<20% Operating Range
262mA
60V
700mA
60V
Output Voltage (V)
578mA
28V
700mA
28V
100
200
300
400
500
600
700
Input :277V
AC
/60Hz
Output Current (mA)
Notes :
(1) experimental instruments :
AC Source : Chroma 61604 / Power Analyzer : Chroma 6630 / Electrical LED Load : Prodigit 3312F / Oscilloscope : Tektronix TDS3014C / Multimeter : Fluke 287
(2) all above curves are measured under 25℃ ambient
(3) all above curves are only for design reference
www.liteon.com
Revised on 2015.03.25
(SL) Ver. C